PPC002-2P Wachendorff Panel PC Display Unit Installation Guide

September 10, 2024
WACHENDORFF

PPC002-2P Wachendorff Panel PC Display Unit

“`html

Specifications:

  • Product: Wachendorff Panel PC Series 1
  • Model: PPC002-xxxxxxxxxxxxxxxxx2P
  • Power Supply Voltage Range: 12 to 36 VDC
  • Operating Voltage: Direct current

Product Usage Instructions:

1. Guarantee Conditions:

Defective devices are repaired or replaced under warranty except
for instances like the appliance being older than 3 years from the
purchase date, damage due to force majeure, accidents, negligence,
improper installation, misuse, unauthorized repairs, or tampering
with labeling.

2. Warning:

Ensure compliance with local and national electrical standards
during installation.

3. Safety Instructions:

Power Supply: Use output power complying with
SELV requirements. Operate the device with a direct current within
the voltage range of 12 to 36 VDC. If using both connections for
power supply in parallel, ensure they originate from the same
voltage source.

Fuse/Switch On: Secure your system/machine. If
the display doesn’t switch on within 5 seconds, turn it off, check
wiring, and retry.

Overvoltage: Ensure DC voltage sources are
adequately isolated.

EMERGENCY STOP: Install a hard-wired EMERGENCY
STOP in every system as per safety recommendations.

Supply Voltage Conditions: Avoid switching on
the device under inductive load or using the same supply voltage as
the controller.

4. Commissioning:

This document details the commissioning and installation of the
Wachendorff Panel PC PPC002xxxxxxxxxxxxxxx2P. Refer to the data
sheet for specifications and applications.

Frequently Asked Questions (FAQ):

Q: What should I do if my display does not switch on?

A: If the display does not switch on within 5 seconds of
powering on, turn it off, check the wiring connections, and then
try switching it on again.

Q: Can I operate the device with a voltage source outside the

specified range?

A: No, the device should only be operated within the specified
voltage range of 12 to 36 VDC to ensure proper functionality and
safety.

“`

Wachendorff Prozesstechnik GmbH & Co. KG Industriestr. 7, D-65366 Geisenheim Phone: 0 67 22 / 99 65 -20 Fax: 0 67 22 / 99 65 -78 E-mail: wp@wachendorff.de www.wachendorff-prozesstechnik.de
Wachendorff Panel PC Series 1
PPC002-xxxxxxxxxxxxxxxxx2P
Installation instructions

Version 1.3

Copyright by Wachendorff Prozesstechnik GmbH & Co. KG, Industriestraße 7, D-65366 Geisenheim,

Phone: +49-6722/9965-20, Fax: -78 All information without guarantee, errors and changes excepted.

Status: 23.08.2024

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P
Table of contents
1. FOREWORD…………………………………………………………………………………………………………3 2. GUARANTEE CONDITIONS…………………………………………………………………………………..3 3. WARNING ……………………………………………………………………………………………………………3 4. SAFETY INSTRUCTIONS ………………………………………………………………………………………3 5. COMMISSIONING ………………………………………………………………………………………………… 4 6. UNPACKING THE APPLIANCE………………………………………………………………………………5 7 ASSEMBLY INSTRUCTIONS…………………………………………………………………………………..5 8. VOLTAGE CONNECTION ……………………………………………………………………………………… 5 9. INTERFACE ARRANGEMENT ……………………………………………………………………………….6 10. INTERFACES …………………………………………………………………………………………………….. 9 11. ORDERING INFORMATION……………………………………………………………………………….. 11 12 COPYRIGHT……………………………………………………………………………………………………… 11 13 DISCLAIMER…………………………………………………………………………………………………….. 11 14 RADIO FREQUENCIES AND MAXIMUM TRANSMISSION POWER………………………… 11 15 OTHER PROVISIONS AND STANDARDS ……………………………………………………………. 11 16 TECHNICAL ADVICE & SERVICE………………………………………………………………………..12
Wachendorff Prozesstechnik GmbH & Co. KG p. 2 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P

1. Foreword

Thank you for choosing a Wachendorff product. We trust that the product will provide you with many years of valuable service. To ensure that the product has a longlife expectancy, please check and compare all connections of the device with the installation instructions before switching on the device.

2. Guarantee conditions

Defective devices are either repaired or replaced. However, this does not apply to the following points:

1. The warranty is void if the appliance is older than 3 years from the date of purchase. 2. Damage caused by force majeure, accident, negligence, improper installation or misuse. 3. The product was put into operation or repaired by unauthorised personnel. 4. By removing or damaging labelling.

3. Warning

Ensure that all local and national electrical standards are complied with when installing the appliance.

4. Safety instructions

Power supply: Use an output power that complies with SELV (Safety Extra-Low Voltage) requirements. The device can only be operated with direct current, voltage range: 12 to 36 VDC,
compatible with most controller DC systems. If both connections are to be used in parallel for the
power supply, the power supply must come from the same voltage source.

Fuse/switch on: Secure your system/machine properly. If the display does not switch on within 5 seconds of switching on, switch it off. Check that the wiring is correct and try switching the device on
again.

Overvoltage: DC voltage sources should ensure adequate isolation from the main power supply and similar hazards.

EMERGENCY STOP: A hard-wired EMERGENCY STOP should be installed in every system to fulfil the ICS safety recommendations.

Supply voltage conditions: Do not switch on the device under inductive load or use the same supply voltage as the controller. Note: The 24 VDC output of some controllers does not supply
enough current to operate the monitor.

Wiring:

a. The length of the power cables should be minimised (max: 500m shielded, 300m unshielded). c. If the wiring could be exposed to a lightning strike or overvoltage, suitable surge arresters must be used. d. Keep AC, high-energy and fast-switching DC power cables separate from signal cables. e. Add a resistor and a capacitor in the parallel circuit between the unearthed DC power supply and the housing earth. This provides a path for static and high frequency power dissipation. Typical values are 1M Ohm and 4,700pF.

You should be aware that the devices could fail due to an internal fault and thus reach an unsafe state. In addition, electrical faults in the user interface can lead to an unintentional start of the connected devices. This can lead to property damage and/or injury to the operator. If you use programmable controls that require an operator, be aware of the safety risks and take appropriate precautions.
Wachendorff Prozesstechnik GmbH & Co. KG p. 3 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P

5. Commissioning

This document describes the commissioning and installation of the Wachendorff Panel PC PPC002xxxxxxxxxxxxxxx2P. Detailed descriptions of the specifications and applications can be found in the data sheet.

Electronic Surroundings
Environment
IP protection class Cleaning instructions

The PPC002-xxxxxxxxxxxxxxxxx2P has been tested and fulfils the European CE requirements. This means that the electronics in the device are protected against external electrical influences. In special cases, however, there is no complete protection. Correct installation of the cables and proper earthing will ensure that the device functions perfectly. Ensure that the device has been installed correctly and that the device
specifications have been adhered to. Avoid installing the devices in locations where mechanical vibrations or shocks are present. Do not work with the appliance in places where there is a risk of explosion, e.g. due to flammable gases, vapours or dust. Do not install the appliance in places where corrosive gases such as SO2 exist. The device is designed for vertical installation on a flat surface. Do not expose the appliance to direct sunlight or other sources of heat. Relative humidity: 10 % to 90 % (non-condensing) IP65 / front
Disconnect the appliance from the power supply before cleaning it. Clean the appliance with cloths moistened with clean water. Do not use liquid or spray cleaning agents for cleaning.

Wachendorff Prozesstechnik GmbH & Co. KG p. 4 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P

6. Unpacking the appliance
Unpack the delivery and check that it is complete. If any damage is found, inform the supplier.
Contents (1) Installation instructions (2) PPC002-xxxxxxxxxxxxxxxxx2P (3) Fastening material
7. Assembly instructions
Use a mounting frame that provides sufficient rigidity. Refer to the data sheet for the cut-out dimensions. Fasten the monitor with all mounting holes and the brackets and screws supplied. Screw torque: 0.294 to 0.441 Nm. (To achieve a watertight effect and to prevent deformation of the panel). Plan sufficient space around the appliance and inside the installation location for ventilation and cables. Take into account the heat from other devices inside the installation location. The ambient temperature around the appliance must be between -10 and 60°C. It is recommended to allow a distance of 3 cm between the back of the appliance and other appliances.

Monitor Installation frame

Screw

Insert the retaining bracket into the square holes and secure with the screw

8. Voltage connection
The Panel PC has 2 connections for the power supply:
2-, 6- or 12-pin terminal strip for 12 to 36 VDC (depending on processor type and display size) Socket for 12 to 36 VDC via external power supply unit (accessory)
Connect: 2-, 6- or 12-pole terminal strip for 12 to 36 VDC: 1. connect the “+” line of your DC voltage source to the “+” input of the 2-pole terminal strip and the “-” line to the “-” input. 2 To avoid potential differences and damage to the USB ports, NEVER connect the Panel PC to several devices with different ground potentials. Socket for 12 to 36 VDC via external power supply unit: An external power supply unit is available as an accessory for connection to the mains voltage of 230 VAC. This is not included in the scope of delivery.
Only use one connection at a time, otherwise damage may occur.
Wachendorff Prozesstechnik GmbH & Co. KG p. 5 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P
8.1. 2-pole terminal: Processors: J4125; i3/i5/i7 up to 10th gen. Intel® CoreTM (display size 10.1″ to 13.3″)
8.2. 6-pole terminal: Processor: i3/i5/i7 up to 10th gen. Intel® CoreTM (display size 15″ to 23.8″)
8.3. 12-pin terminal (supplied with plug): Processor: J6412; i3/i5/i7 from 12th gen. Intel® CoreTM (display size 10.1″ to 23.8″)
9. Interface arrangement 9.1 Processor Intel® Celeron® J4125: Top view up to and including 12.1″:
Bottom view including 12.1″:
Wachendorff Prozesstechnik GmbH & Co. KG p. 6 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P
Top view 13.3″ to 23.8″: Bottom view 13.3″ to 23.8″: 9.2 Intel® Celeron® J6412: Top view up to and including 12.1″: Bottom view up to and including 12.1″: Top view 13.3″ to 23.8″: Bottom view 13.3″ to 23.8″:
Wachendorff Prozesstechnik GmbH & Co. KG p. 7 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P
9.3 Intel® CoreTM i3/i5/i7 up to 10th gen: Top view up to and including 13.3″:
Bottom view up to and including 13.3″:
Top view 15″ to 23.8″:
Bottom view 15″ to 23.8″: 9.4 Intel® CoreTM i3/i5/i7 from 12th gen: Top view 10.1″ to 23.8″:
Bottom view 10.1″ to 23.8″: Wachendorff Prozesstechnik GmbH & Co. KG p. 8 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P

10. Interfaces

10.1: Processor Intel® Celeron J4125® Interface USB Serial Ethernet WLAN Bluetooth: Display Audio SIM card

Quantity and description 2 x USB 2.0 type A, 2 x USB 3.0 type A 2x RS-232 DB-9 2x RJ-45 Gigabit Ethernet 802.11abgn/ac/d/e/i/h/w Bluetooth 4.0 1x HDMI, 1x VGA 1x audio out, 3.5 mm jack Without function (optional equipment)

10.2: Processor Intel® Celeron® J6412 Interface USB Serial
Ethernet WLAN Bluetooth: Display Audio GPIO SIM card

Quantity and description 2 x USB 2.0 type A, 2 x USB 3.0 type A 1x RS-232 DB-9; 1x RS-232 terminal strip; 1x RS484 terminal strip 2x RJ-45 Gigabit Ethernet 802.11abgn/ac/d/e/i/h/w Bluetooth 4.0 1x HDMI, 1x VGA 1x audio out, 3.5 mm jack 5x GPIO terminal strip Without function (optional equipment)

12-pin screw terminal (supplied with plug):

PIN Description of the

1

12-36 VDC (supply)

2

GND (supply)

3

GND

4

RS232 TX

5

RS232 RX

6

RS485A

7

RS485B

8

IO0 (TTL)

9

IO1 (TTL)

10

IO2 (TTL)

11

IO3 (TTL)

12

IO4 (TTL)

Wachendorff Prozesstechnik GmbH & Co. KG p. 9 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P

10.3: Intel® CoreTM i3/i5/i7 up to 10th gen:

Interface

Quantity and description

USB

2 x USB 2.0 type A, 2 x USB 3.0 type A

Serial

1x RS-232 DB-9; 1x RS-232 terminal strip

Ethernet

2x RJ-45 Gigabit Ethernet

WLAN

802.11abgn/ac/d/e/i/h/w

Bluetooth:

Bluetooth 4.0

Display

1x HDMI, 1x VGA

Audio

1x audio out, 3.5 mm jack

GPIO

1x GPIO terminal strip

SIM card

Without function (optional equipment)

6-pin screw terminal (only 15″ to 23.8″):

PIN Description of the

1

DC+: 12-36 VDC (supply)

2

DC-: GND (supply)

3

GND

4

RS232 RX

5

RS232 TX

6

5 VDC

10.4: Intel® CoreTM i3/i5/i7 from 12th gen:

Interface

Quantity and description

USB

2 x USB 2.0 type A, 2 x USB 3.0 type A

Serial

1x RS-232 DB-9; 1x RS-232 terminal strip; 1x

RS484 terminal strip

Ethernet

2x RJ-45 Gigabit Ethernet

WLAN

802.11abgn/ac/d/e/i/h/w

Bluetooth:

Bluetooth 4.0

Display

1x HDMI, 1x VGA

Audio

1x audio out, 3.5 mm jack

GPIO

5x GPIO terminal strip

SIM card

Without function (optional equipment)

12-pin screw terminal (supplied with plug):

PIN Description of the

1

12-36 VDC (supply)

2

GND (supply)

3

GND

4

RS232 TX

5

RS232 RX

6

RS485A

7

RS485B

8

IO0 (TTL)

9

IO1 (TTL)

10

IO2 (TTL)

11

IO3 (TTL)

12

IO4 (TTL)

Wachendorff Prozesstechnik GmbH & Co. KG p. 10 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P

11. Ordering information

Article description
Panel PC, xx” TFT, with or without touch
External power supply unit, 230 VAC to 24 VDC, 2.5 A with hollow plug (without 230 VAC connection cable), CPU: J14125 / J6412 / Intel® CoreTM 6th/7th Gen External power supply unit, 230 VAC to 24 VDC, 4 A with hollow plug (without 230 VAC connection cable), CPU: Intel® CoreTM 8th/10th Gen. External power supply unit, 230 VAC to 24 VDC, 5 A with hollow plug (without 230 VAC connection cable), CPU: Intel® CoreTM 12th Gen. 230 VAC connection cable Power supply unit Panel PC

Order no. PPC002-xxxxxxxxxxxxxxxxx2P PPC-PWRADAP_01_24VDC2.5A
PPC-PWRADAP_01_24VDC4A
PPC-PWRADAP_01_24VDC5A
PPC-PWRCRD_01

12. Copyright

This document is the property of Wachendorff Prozesstechnik GmbH & Co. Copying and reproduction are prohibited without prior authorisation. The contents of this documentation refer to the device described therein.

13. Disclaimer

All technical content within this document may be modified without prior notice. The content of this document is subject to periodic revision. Repairs will be charged to the user in the event of loss due to fire, earthquake, third party interference or other accidents, or in the event of intentional or accidental misuse or abuse, or use under abnormal conditions. Wachendorff Prozesstechnik is not liable for accidental loss due to use or non-use of this product, such as loss of business revenue. Wachendorff Prozesstechnik is not liable for the consequences of improper use.

14. Radio frequencies and maximum transmission power

MODE IEEE802.11 b/g/n IEEE802.11 a/n/ac Bluetooth/BLE

Frequency band 2400 – 2483.5 MHz 5150 – 5725 MHz 2400 – 2483.5 MHz

Transmission power 20dBm EIRP max (100mW) 23dBm EIRP max (200mW) 10dBm EIRP max (10mW)

15. Other provisions and standards
WEEE information Disposal of old electrical and electronic equipment (valid in the European Union and other European countries with a separate collection system) This symbol on the product or on the packaging means that this product must not be treated as household waste. Instead, this product should be taken to the appropriate disposal point for the recycling of electrical and electronic equipment. If the product is disposed of correctly,
you will help to prevent negative environmental impacts and damage to health that could be caused by improper disposal. Recycling material will preserve our natural resources. For more information on how to recycle this product, please contact your local city office, your household waste collection service or the retailer where you purchased this product.

Wachendorff Prozesstechnik GmbH & Co. KG p. 11 from 12

Installation instructions PPC002-xxxxxxxxxxxxxxxxx2P
RoHS Directive The device complies with the latest version of the 2011/65/EU Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (commonly referred to as the Restriction of Hazardous Substances Directive or RoHS).
RED Directive The device complies with the latest version of the 2014/30/EU (electromagnetic compatibility directive) and 2014/53/EU (Radio Equipment Directive, RED) directives.
A complete version of the EU Declaration of Conformity is available on request.
16. Technical consulting & s ervice
If you have any questions about the product, you can find technical support on our homepage: https://www.wachendorff-prozesstechnik.de/tbs/
For technical support after a purchase (commissioning, project planning, parameterisation, configuration, programming, etc.), please dial: +49 6722 9965-966 or send an e-mail to: support@wachendorff.de
For application advice before a possible purchase (product selection, suitability, recommendation), please call: +49 6722 9965-544 or send an e-mail to: beratung@wachendorff.de
In the event of a repair or device failure, please contact our technical advice & service team first. More than 75% of all cases are resolved over the phone, saving you any costs or the dispatch of your product. You will also receive information on the return procedure.
For the return process, please go to our homepage at https://www.wachendorffprozesstechnik.de/garantie-und-reparatur, open the “Request return number” form and follow the instructions. After we have checked your form, we will send you a document with a return authorisation number (RSN) by e-mail. Please enclose this document with your return.
Note: The return authorisation number (RSN) is generated specifically for your return. It regulates the conditions and ensures direct allocation and faster processing of your return. It is therefore extremely important that the RSN is enclosed with your return.
Contact: Support: Phone +49 (0) 67 22 / 99 65 -966, e-mail to support@wachendorff.de Application advice: Tel. +49 (0) 67 22 / 99 65 -544, e-mail to beratung@wachendorff.de Visit us on the Internet: www.wachendorff- prozesstechnik.de
Your partner:
Wachendorff Prozesstechnik GmbH & Co. KG Industriestrasse 7 – D-65366 Geisenheim
Phone: +49 (0) 67 22 / 99 65 – 20 Fax: +49 (0) 67 22 / 99 65 – 78 E-mail: wp@wachendorff.de www.wachendorff-prozesstechnik.de