EASYswitch ES240-110 Remote Switch Mains Electricity Installation Guide

August 31, 2024
EASYswitch

EASYswitch ES240-110 Remote Switch Mains Electricity Installation Guide

CONFIGURATION INSTRUCTIONS

  1. The ES240-110 is shipped configured as per the box label but, may be re-configured as follows before connection of mains power.
    HOWEVER STEP 3 MUST ALWAYS BE DONE

  2. With power disconnected remove the lid by unfastening the 4 corner screws.
    NC operation
    Fit both links as shown at left

NO operation
Fit both links as shown at right

Fit output Brown lead to selected output terminal above

240 volt operation
Fit both links as shown at left

110 volt operation
Fit one only link as shown at right

  1. Strike out on the label the voltage description NOT SELECTED.
  2. Securely refit lid before connection of mains power

INSTALLATION INSTRUCTIONS

  1. Connect the C14 male socket to a source of mains A.C. Power, as configured above, and switch on.
    2a/ For NO operation the LED must be GREEN (input on) and the load de- energised.
    2b/ For NC operation the LED must be RED (active out) and the load energised.

  2. If the configured condition is not present, switch off, disconnect and return to supplier.

  3. Apply a shorting link directly to the control contacts terminals of the EASYswitch

  4. 5a/ For NO operation the LED must be RED (active out) and the load energised.

  5. 5b/ For NC operation the LED must be GREEN (input on) and the load de-energised.

  6. If the configured condition is not present, switch off, disconnect and return to supplier.

  7. Connect the C13 female plug to the controlled load

  8. Attach bell wire, signal wire or similar to the control contacts screw terminals.

  9. Run the control wire to the remote switching location and connect to volts free switch mechanism.

  10. f using an open collector transistor switch, connect the collector to the terminal marked O.C. and the common rail to the terminal marked OV.

  11. If using 5, 12 or 24 volt triggering connect the + signal to the terminal marked O.C. and the common rail to the terminal marked 0V

  12. Verify correct operation with remote switching

SPECIFICATIONS

Weight: 310 grams (11oz) boxed
Size: 146mm (5.75in) x 67mm (2.63in) x 45mm (1.77in).
LED Indicator: Green = Mains input on, Red = Mains active out.
Electrical life: 1 x 10 operations @ 240V, 16A, resistive load.

derate accordingly for inductive and capacitive loads
Contact capacity: Inrush peak currents up to 80A max 20ms.

Control ES24 with line requirements: 24VDC open circuit and 3mA

N15569

www.booleanengineering.com

OTHER MODELS

ES240-RCBO, one circuit switch board, 10 amp breaker and RCD safety switch.

ES240-110-PFD, EASYswitch with power fail detect output.

ES240-110-SK, EASYswitch with security key protected operation.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>