Product Specifications
- Input Voltage (Volts DC): 12/24V
- Max Input Current (A): 60
- Standby Current Consumption (mA): 290
- Isolation mode Current Consumption (mA): 178 IP Rating
- Weight (kg): Not specified
- Dimensions L x W x D (mm): 290 x 178 x 77
FAQ
- Q: Who should carry out the installation of this product?
- A : Installation must be carried out by competent personnel with adequate knowledge of electrical installations.
- Q: Where can I find the latest documents for the products?
- A : You can find the latest documents on our website: www.intellitecmv.com
PRODUCT SPECIFICATION
Input Voltage (Volts DC) | 12/24V |
---|---|
Max Input Current (A) | 60 |
Standby Current Consumption (mA) | 35 mA ± 10 |
Isolation mode Current Consumption (mA) | 0 mA |
IP Rating | IP20 |
Weight (kg) | 2.5 kg |
Dimensions L x W x D (mm) | 290 x 178 x 77 |
INPUTS
16x Digital (Pos/Neg Configurable)
2x Voltage Sense (Analog)
2x Temperature Sensors
2x Vehicle CAN
1x 3rd Party CAN
1x LIN
1x Intelli CAN
OUTPUTS
24x Low Power Outputs (2A Max)
12x Medium Power Outputs (10A Max)
4x High Power Outputs (30A Relay Controlled)
6x Low Current Positive Signal Coil Driver (1A)
6x Low Current Negative Signal Coil Driver (1A)
Type D Siren Amplifier (1x 200W or 2x 100W)
CAN BUS – Baud Rates
50 Kbits/s
83.33 Kbits/s
100 Kbits/s
125 Kbits/s
250 Kbits/s
500 Kbits/s
666 Kbits/s
1000 Kbits/s
INSTALLATION
Schematic:(mm)
Schematic:(mm) Mounting
Minimum required spacing around the unit.
Schematic:
Connector Plug Wiring **
**
Connector Plug Wiring
MULTIFUNCTION SWITCH
The switch on the front of the module is multifunctional depending on how it is interacted with. Using the information below, the different modes can be used:
- 5 Second Hold. Hold During Power Up Erase the program form the unit.
- Enable / Disable the Bluetooth and GPS capabilities of the module. (If Present)
ICONNEX GUI
- The iConnex Response and Patrol Keypads can be programmed via the iConnex GUI software package.
- To Download the GUI please visit: www.intellitecmvcom/pages/downloads
- The iConnec GUI is the utility to write and upload programs to the module
icon next GUI Software\ Available as a free-of-charge download
Connecting the Response to the GUI
- Use the USB on the front of the module to connect to the GUI.
- Ensure the iConnex Response module is powered when connecting to the GUI.
- GREEN is a Data status LED
- When the green LED is ON, that signifies there is a connection to the GUI.
- When the green LED is OFF, that signifies there is no connection to the GUI.
- RED is an Error LED
- When the red LED is ON, that signifies there is a programming error.
DIAGNOSTIC LED
The module has a red, blue and green LED for diagnostic use.
BLUE is a Vehicle 1, Vehicle 2 and Third Party CAN status LED
- When the blue LED is ON, that signifies there is CAN traffic.
- When the blue LED FLASHES, that signifies a CAN state change for a selected CAN message. When the blue LED is OFF, that signifies there is no CAN traffic being received
GREEN is the Intelli CAN status LED
- When the green LED is ON, that signifies the module has power.
- When the green LED FLASHES, that signifies communication.
- When the green LED is OFF, that signifies the module has no power.
RED is an Error LED
- When the red LED is ON, that signifies there is an error.
- Using the iConnex GUI the error log can be used to identify the errors. Once the error logs are clear the red LED will go OFF.
KEYPAD
Connex Response Patrol Keypads
-
ICX-SW16B Type 16 Patrol Keypad – Bottom Cable Mount 8×2 Buttons
-
ICX-SW16T Type 16 Patrol Keypad – Top Cable Mount 8×2 Buttons
-
ICX-SW16B-14B Type 16 Patrol Keypad – Bottom Cable Mount 6×2+2 Bottom Buttons
-
ICX-SW16T-14B Type 16 Patrol Keypad – Top Cable Mount 6×2+2 Bottom Buttons
-
ICX-SW16B-14T Type 16 Patrol Keypad – Bottom Cable Mount 6×2+2 Top Buttons
-
ICX-SW16T-14B Type 16 Patrol Keypad – Top Cable Mount 6×2+2 Top Buttons
-
ICX-SW10B Type 10 Patrol Keypad – Bottom Cable Mount 5×2 Buttons
-
ICX-SW10T Type 10 Patrol Keypad – Top Cable Mount 5×2 Buttons
-
ICX-SW10B-09B Type 10 Patrol Keypad – Bottom Cable Mount 4×2+1 Bottom Button
-
ICX-SW10T-09B Type 10 Patrol Keypad – Top Cable Mount 4×2+1 Bottom Button
-
ICX-SW10B 09T Type 10 Patrol Keypad – Bottom Cable Mount 4×2+1 Top Button
-
ICX-SW10T-09T Type 10 Patrol Keypad – Top Cable Mount 4×2+1 Top Button
-
ICX-SW10B-08B Type 10 Patrol Keypad – Bottom Cable Mount 3×2+2 Bottom Buttons
-
ICX-SW10T-08B Type 10 Patrol Keypad – Top Cable Mount 3×2+2 Bottom Buttons
-
ICX-SW10B-08T Type 10 Patrol Keypad – Bottom Cable Mount 3×2+2 Top Buttons
-
ICX-SW10T-08T Type 10 Patrol Keypad – Top Cable Mount 3×2+2 Top Buttons
-
ICX-SW12R Type 12 Patrol Keypad – Right Cable Mount 12 x Buttons Inline
-
ICX-SW12R-10R Type 12 Patrol Keypad – Right Cable Mount 10+2 Right Buttons Inline
-
ICX-SW12R-10L Type 12 Patrol Keypad – Right Cable Mount 10+2 Left Buttons Inline
ACCESSORIES
icon next Response Accessories & Fitting Kits
- ICX-R-LOOM iConnex Response Installation Wiring loom
ICX-R-YSC iConnex Patrol Keypad Y-Splitter Cable
ICX-R-FIT iConnex Response Fitting Kit
Copyright © 2019 Intellitec MV Ltd
The instructions within this booklet (User’s Manual) must be read thoroughly
before any installation work, testing or general use. We recommend this
booklet is kept in a safe place that can be easily retrieved for any future
referral. Installation must be carried out by competent personnel with
adequate knowledge of electrical installations. All necessary precautions must
be taken to ensure this product is fitted correctly, securely and safely into
the desired application. This product must not interfere with road safety or
OEM safety systems fitted to the vehicle All necessary checks must be carried
out by installer to ensure this device is used only in the intended
application and also does not conflict with any road laws in all countries the
vehicle may be driven within. Intellitec MV Ltd reserves the right to update
this document (User’s Manual) without notification at any time.
- You will find the latest documents for our products on our website: www.intellitecmv.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>