Schneider Electric CCT599002 Wiser Smoke Detector User Manual
- August 2, 2024
- Schneider Electric
Table of Contents
Schneider Electric CCT599002 Wiser Smoke Detector
Specifications
- Product Name: Wiser Smoke Alarm – Battery
- Usage: Detect smoke and rapid increase in temperature
- Features: Photoelectric sensor, temperature sensor, Wiser app integration
Product Usage Instructions
The Wiser Smoke Alarm – Battery is designed to detect smoke and heat caused by fire. It utilizes a photoelectric sensor and a temperature sensor to provide accurate detection. When connected to the Wiser system, it can send notifications to the user via the Wiser app.
- Turn the power switch to the ON position on all devices.
- Short press the Test/Hush button 3 times within 2 s on the primary device.
- Identify a secondary device and short press the Test/Hush button 3 times within 2 s to establish RF connection.
- Install the mounting base on the wall or ceiling using provided wall plugs and screws.
- Position the device on the mounting base ensuring alignment of arrows.
- Rotate the device clockwise until it locks onto the mounting base.
- Rotate the device anti-clockwise to the end position.
- Insert a flat-headed screwdriver into the small opening of the device to unlock it from the base.
- Hold the screwdriver in place and rotate the device anti-clockwise to detach it from the base.
FAQ
- Q: Can I replace the battery in the Wiser Smoke Alarm?
- A: The battery in the Wiser Smoke Alarm is sealed and non-replaceable. Do not attempt to recharge, disassemble, or incinerate the battery to avoid hazards.
- Q: How does the device communicate with the user?
- A: When connected to the Wiser system, the device sends notifications to the user via the Wiser app in case of smoke or heat detection.
NOTICE
EQUIPMENT INSTALLATION HAZARD
- Always operate the product in compliance with the specified technical data.
- Keep the installation instructions for the entire lifetime of the product.
- Failure to follow these instructions can result in equipment damage.
WARNING
- SEALED BATTERY HAZARD
- Attention: Non-replaceable sealed battery.
- Do not recharge, disassemble or incinerate the battery.
- Failure to follow these instructions can result in death, serious injury or equipment damage.
About this product
The Wiser Smoke Alarm – Battery (device) uses a photoelectric sensor to detect
smoke generated by fire. It also includes a temperature sensor that detects
heat caused by rapid increase in temperature. When connected to the Wiser
system, the device sends notifications to the user via the Wiser app.
Package contents
- A Wiser Smoke Alarm Battery
- B Mounting base
- C 2 Screws (M3.5 × 20 mm), 2 wall plugs
- D Primary label
- E Installation instructions
- F Dust cover
Operating elements
- G Status LED (Amber, Green, and Red LED)
- H Standby LED (Red LED)
- I Test/Hush button
- J Power switch
- K Setup/Reset Button
Choose suitable location to install
NOTICE
EQUIPMENT DAMAGE
- Do not install in garages, kitchens, bathrooms or any area with high levels of moisture, dirt or insects.
- Do not remove the dust cover until all construction work is completed. Construction dust and chemicals causes fault detection and false alarms.
- Install more than 1 m away from air conditioners/ heater vents and fans, electrical sources, appliances and fittings.
Failure to follow these instructions can result in equipment damage.
The device can be installed on:
- Flat ceiling
- Inclined ceiling
- Wall
Interconnecting devices without Wiser Hub
The smoke alarms (devices) can be connected via RF connections even without a
Wiser Hub.
Read the following steps before interconnecting the devices without Wiser Hub.
Important: Turn the power switch to the ON position on all devices. Make
sure that all devices are close together during the below operations.
- Identify a device and mark it as Primary with the label supplied. Other devices are considered Secondary.
- Short press the Test/Hush button 3 times within 2 s on the primary device. The Standby LED turns On for 30 s once it is in pairing mode.
- Identify a secondary device and short-press the Test/Hush button 3 times within 2 s. The Standby LED blinks 3 times on both primary and secondary devices. Then on the primary device, the Standby LED again turns on for 30 s indicating a successful RF connection.
Note
- Repeat step 3 on all secondary devices.
- To exit from pairing mode, short press (< 0,5 s) the Test/Hush button 3 times on the primary device. The Standby LED turns off indicating that the primary device is not in pairing mode.
Installing the device
- Install the mounting base on the wall or ceiling with provided wall plugs and screws.
- Position the device on the mounting base. Ensure that the arrows on the device and mounting base are aligned.
- Rotate the device clockwise until it locks onto the mounting base.
Note: Ensure that the device is parallel to the wall, otherwise rotate and adjust it to a maximum 10°.
Removing a device from the mounting base
- Rotate the device anti-clockwise to the end position.
- Insert a flat-headed screwdriver into the small opening of the device to unlock it from the mounting base.
- Hold the screwdriver into the small opening and then rotate the device anti-clockwise to pull it off from the mounting base.
Disconnecting a secondary device from RF interconnection
Note
- To remove a secondary device from the mounting base refer to the section “Removing a device from the mounting base”.
- Do not remove the primary device.
- Read the following steps before disconnecting a secondary device.
-
Ensure that the power switch is in OFF/AUTO position.
-
Press and hold the Test/Hush button and simultaneously turn the power switch to ON position.
The standby LED turns On for 3 s. -
Continue to hold the Test/Hush button until the Standby LED turns Off. Then release the Test/Hush button.
-
Short press the Test/Hush button when the Standby LED is on for 3 s. The Standby LED blinks for 5 s indicating disconnecting of RF interconnection also the Status LED blinks green for 7 times.
Note: After disconnecting the secondary device from RF interconnection, turn the power switch to OFF/ AUTO position.
Operating the device
CAUTION
DO NOT USE OPEN FLAME
Do not use an open flame of any type to test a device.
Failure to follow these instructions can result in injury or equipment damage.
- Testing the device Important:
- Test the device once in a month to ensure proper operation.
- If the smoke alarm is installed in a mobile home, test weekly and before every journey.
- Press the Test/Hush button on each device for more than 3 s until an alarm goes off. If the alarm does not go off, either the battery is low or there may be another issue in the device. Refer to Troubleshooting.
- Testing all interconnected devices via one operation
- Select any interconnected device.
- Press and hold the Test/Hush button for more than 10 s until an alarm goes off on all interconnected devices. If there is no alarm triggered on the interconnected devices, ensure that the wireless interconnection setup is correct. And the distance between each device is within the specification.
- Silencing the device:
Hush feature
- During an alarm event, identify the device(s) which is/are blinking red LEDs then short press the Test/ Hush button on the device to stop the alarm.
- Note: The device is not sensitive to smoke/high temperature for 10 minutes. Later the device resumes to normal operation. During this hush time, the Standby LED blinks once every 8 s.
- In an interconnected group, if more than one device has blinking red LEDs and an active alarm, short-press the Test/Hush button on all devices. All interconnected devices stop the alarm within 5 to 10 s.
Note: Wait for 10 minutes before performing any test to avoid malfunctioning of the device.
Temporary disablement
To temporarily disable the smoke detection in a device, short press the
Test/Hush button once when the device is in Standby mode. The specific device
will not be sensitive to smoke for 10 minutes. During this mode, the Standby
LED blinks once every 8 s.
Snoozing the device alerts
Low battery
When the battery is low, the standby LED blinks and 1 beep occurs every 48 s.
You can snooze the low battery indication for 10 hours by short-pressing the
Test/ Hush button.
Important: The user must replace the device within 30 days of the first
alert.
Fault detection
When a fault is detected in the device, the standby LED blinks and 2 beep
occurs every 48 s. You can snooze the indication for 10 hours by short-
pressing the Test/Hush button.
Alarm memory
- In an interconnected group, the Standby LED on the triggered device blinks once every 2 still 72 hours after the alarm is stopped. This allows you to identify the device that was triggered by smoke/high temperature.
- Short press the Test/Hush button once to snooze the blinking LED for 10 hours.
Read the full device user guide online
Scan the QR code for complete information about the device, including
operation, configuration and using the product with a Wiser system.
Standby LED and alarming sound indications
Operating mode| Standby LED| Alarming Sound|
Duration
---|---|---|---
Normal mode / Standby mode| Blinks every 48 s| OFF| —
ALARM MODE| Local alarm| Blinks every 1 s| 3 beeps
every 4 s
| ****
—
Intercon- nected alarm
| ****
OFF
| ****
3 beeps
every 4 s
| ****
—
Test mode
| ****
1 blink
every 1 s
| ****
3 beeps
every 4 s
| Until the Test/ Hush button is released
Wireless interconnection test| ****
OFF
| Continuous 3 beeps every 4 s| ****
25 s
Hush mode| Blinks every 8 s| OFF| 10 min
Low battery mode| Blinks every 48 s| 1 beep every
48 s
| End of life: replace the device
Fault detection mode
| ****
2 blinks
every 48 s
| ****
2 beeps
every 48 s
| Until the detected fault is cleared
Operating mode| Standby LED| Alarming Sound|
Duration
---|---|---|---
SNOOZE MODE| Low battery| Blinks every 24 s| OFF| 10 hrs
Fault detection| 2 blinks
every 24 s
| OFF| 10 hrs
Alarm memory| Blinks every 48 s|
OFF
|
10 hrs
Troubleshooting
Troubleshooting|
---|---
Issue| Resolution/Action
The device does not produce an alarm sound when tested| 1. Ensure that
the device is installed correctly. If you are unsure then remove and reinstall
the device (Refer to “Installing the device”).
2. Press the Test/Hush button until an alarm sound is produced. Do not press consecutively.
3. If the problem persists or if you have questions about the warranty, contact the customer care center.
The device beeps and the Standby LED blinks every 48 s| The battery may
be low or drained. Replace the device.
The device beeps twice and Standby LED blinks every 48 s| 1. Clean the
device. Refer to
“Maintenance”.
2. If the problem persists or if you have questions about the warranty, contact the customer care center.
The device produces an alarm sound unexpectedly without smoke or steam| 1. Identify the triggered device, indicated by a blinking Standby LED and 3 beeps every 4 s.
2. Press the Test/Hush button to pause the alarm sound. The connected device stops alarming in 5 to 10 s.
3. Clean the device. Refer to “Maintenance”.
4. Reinstall the device and test.
5. If the problem persists or if you have questions about the warranty, contact the customer care center.
Note: After an alarm event, the device
that has a blinking Standby LED every 2 s is the triggered device. Identify the device and follow steps 3 to 5.
False Alarm
Important: In the event of a false alarm in an interconnected group, it
is important to identify the triggering device(s).
These devices must be cleaned, serviced, or replaced if necessary.
Maintenance
It is recommended that the device is inspected monthly and it is free from dirt, dust, and insects. The device can be vacuumed(strongly recommended) or brushed with a soft brush to remove accumulated dust, dirt or kitchen grease. Wipe the device(s) with a small amount of insect surface spray and cloth every 3 to 6 months to mitigate insect ingress.
Important
- Always test the device after cleaning.
- If necessary refer to “Installing the device”, for more installation information.
NOTICE
EQUIPMENT MAINTENANCE INSTRUCTIONS
• Test the device regularly to ensure its functionality
and the battery is in good condition.
• Replace the device after 10 years from the date of manufacturing.
• Do not open the device casing or repair yourself. There are no serviceable parts inside.
Failure to follow these instructions can result in equipment damage.
Technical data
- Operating Current: <70 mA
- Sensing Type: Photoelectric. This alarm contains NO radioactive material.
- Operating Temperature: 0 °C to 45 °C
- Ambient Humidity: 5% to 95%
- Interconnecting: RF, max. 40 devices in one network
- Communication protocol: Zigbee, max. 40 devices in one network
- Operating frequency: Zigbee: 2405 – 2480 MHz RF: 868 MHz
- Wireless Range: 40m indoor line of sight
- Horn Level: 85 dB at 3 m
- Dimensions (H × W × D): 89 × 89 × 33.5 mm
- Standard: EN 14604:2005 + AC:2008
- Certification: Zigbee 3.0
Features certified by NF marking
Trademarks
- Wiser™ is a trademark and the property of Schneider Electric SE, its subsidiaries and affiliated companies.
- Zigbee® is a registered trademark of the Connectivity Standards Alliance.
- Other brands and registered trademarks are properties of their relevant owners.
Schneider Electric Industries SAS
-
35 rue Joseph Monier F-92500 Rueil-Malmaison France
-
Consumer helpline
-
Tel: +33 0825 012 999
-
1116-CPR-147
-
DOP1000021
-
EN 14604: 2005 + AC: 2008
Certification Body: AFNOR Certification
- Website: www.afnor.org
- https://certification.afnor.org/securite/nf-securite-incendie-domestique
- The CE mark affixed to this product confirms its compliance with the European Directives which apply to the product and, in particular, its compliance with the harmonized specifications of standard EN 14604:2005 relating to Construction Products
- Regulation 305/2011
- The NF – NF-DOMESTIC FIRE SAFETY mark assures as to the safety and consistent quality inspected by experts.
- Through its rigorous and exhaustive inspections (holder’s quality management system, product inspections, audits and monitoring tests, etc.), the NF mark represents a comprehensive guarantee for consumers that the certified products are compliant.
- The NF – NF-DOMESTIC FIRE SAFETY mark confirms the product’s compliance with certification rules NF 292.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>