ELGAS VM3010 Smart Volumetric Adapter for Diaphragm Gas Meter Installation Guide
- July 22, 2024
- ELGAS
Table of Contents
ELGAS VM3010 Smart Volumetric Adapter for Diaphragm Gas Meter
Product Information
Specifications
- Product: Smart Volumetric Adapter for Diaphragm Gas Meter
- Models: VM3010, VM3020
- Input: Hall effect detection of turns on gas meter’s axle
- Reporting & Outputs: Gas consumption in cubic feet, Low battery, Temperature
- Data Interface: API, Email (to supplier and/or consumer), Raw data, Online dashboard, Client mobile app
- Automated Testing: Network status, Battery status
- Radio Specifications: VM3010: Bluetooth BLE, VM3020: Bluetooth BLE, LTE-M, NB-IoT
- Environmental Specifications: Operating and storage temperature range: -40C to 60C, Relative humidity range: 0% to 100%, Enclosure rating: IP68
- Warranty: 2 years
- Features: Ready-to-install, long-lasting battery, hardware installation included
- Certifications: Hazardous Location Classification, Orodek Bada Atestacji i Certyfikacji OBAC, FCC ID: 2ADQFVM30X0, IC ID: 12649A-VM30X0
- Adapter Dimensions: Height: 13.9 cm (5.5 in), Width: 8.4 cm (3.3 in), Depth: 3.6 cm (1.4 in)
Product Usage Instructions
-
Installation
Always follow your local regulations and standards when installing the Smart Volumetric Adapter for Diaphragm Gas Meter. If required, consult a certified expert to ensure compliance with local regulations. -
Operating Conditions
The device can operate within a temperature range of -40C to 60C and a relative humidity range of 0% to 100%. Ensure the device is not exposed to conditions outside these ranges. -
Power Management
The device features a long-lasting battery. Monitor battery status through the provided reporting features and replace the battery as needed to ensure uninterrupted operation. -
Data Reporting
Utilize the various reporting outputs to monitor gas consumption, battery levels, and temperature. Access data through the API, email notifications, raw data, online dashboard, or the client mobile app. -
Radio Connectivity
Depending on the model, the device supports Bluetooth BLE and additional technologies like LTE-M and NB-IoT for enhanced connectivity options.
Frequently Asked Questions (FAQ)
Q: What should I do if I encounter issues with the device?
A: In case of any issues with the Smart Volumetric Adapter, contact our
support team at +1 514-673-0244 or
email support@otodata.com for assistance.
Emergency support is available 24/7 at
1-833-529-9499.
WARNING
In order to guarantee a safe, explosion-proof environment and ensure
conformity to the Certifications (page 1), the below requirements must be
fulfilled without fail: 1. Ambient temperature range is -40ºC ≤ Tamb ≤ +60ºC,
2. The device shall not be installed in a location where the external
conditions are conducive to the build-up of electrostatic charge (under
certain extreme circumstances, the plastic enclosure may store an ignition-
capable level of electrostatic charge), 3. DO NOT RUB. The equipment shall
only be cleaned with a damp cloth.
INSTALLATION
Always follow your local regulations and standards. If locally required,
consult a certified expert to ensure your installation is compliant.
Specifications
Input
Hall effect detection of turns on gas meter’s axle
Reporting & Outputs
Reporting| Gas consumption in cubic feet Low battery
Temperature
Data Interface| API
Email (to supplier and/or consumer) Raw data
Online dashboard Client mobile app
Automated Testing| Network status Battery status
Radio Specifications
Technologies| VM3010: Bluetooth BLE
VM3020: Bluetooth BLE, LTE-M, NB-IoT
Environmental Specifications
Operating and storage temperature range| -40°C to 60°C -40°F to 140°F
Relative humidity range| 0% to 100%
Enclosure rating| IP68
Warranty| 2 years
Features
Ready to install, long-lasting battery, hardware installation included.
Certifications
Hazardous Location Classification
Otodata’s volumetric gas meters are certified by QPS Evaluation Services Inc.
for use in North America. I.S. Class I, Div 1, Groups CD, T3. Class I, Zone 0,
AEx ia IIB T3 Ga. Standards applied: UL 60079- 0:2019; Ed. 7 and CSA C22.2
NO. 60079-0:19, UL 60079-11:2013; Ed.6 and CSA-C22.2 NO. 60079-11:14, UL/CSA
61010-1-12.Volumetric gas meters are certified by Ośrodek Badań Atestacji i
Certyfikacji OBAC for use in the European Union and internationally.
IECEx
Classification: Ex ia IIB T3 Ga, Certificate: IECEx OBAC 23.0007X, Standards
applied: IEC 60079-0:2017 – IEC 60079-11:2011
ATEX
Classification: II 1G Ex ia IIB T3 Ga, Certificate: OBAC ATEX 0311X
Standards applied: EN 60079-0:2017 – EN 60079-11:2011
Radio Certifications
FCC ID: 2ADQFVM30X0, IC ID: 12649A-VM30X0
Adapter Dimensions
Height: 13.9 cm (5.5 in), Width: 8.4 cm (3.3 in),
Depth: 3.6 cm (1.4 in)
Ordering Options
VM3020-VSXX-CBLK
Smart Volumetric Adapter for a gas meter with Bluetooth interface and cellular
network modem. VM3010-V0XX-CBLK
Smart Volumetric Adapter for a gas meter with Bluetooth interface.
FCC STATEMENT
Replace “XX” with the appropriate regional code. If available, replace
“CBLK” with the client branding code.
This device complies with part 15 of the FCC Rules. Changes or modifications
not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment. Operation is subject to the
following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This device is compliant with Industry Canada’s RSS standards for license- exempt radio apparatuses. Authorized use depends on the following two conditions:
- The device must not create radio interference, and
- The device user must accept all radio interference, even if this interference could potentially impair its functioning.
This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To comply with FCC RF exposure compliance recommendations, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons.
Safety requirements
- Before installation and use, it is essential to read and understand this instruction manual; paying particular attention to the Ex marking,* special conditions of use, and technical parameters.
- The device can only be connected to equipment with proper, fitted, intrinsically safe parameters.
- NEVER carry out any service manipulations in the presence of an explosive atmosphere.
- The Volumetric Meter (VM3010 or VM3020) is delivered with connected batteries.
- The start-up of the device requires only proper use of the user interface.
- Activities related to the starting up of the device do not influence Ex safety.
- This device was not designed to be maintained or repaired. This device was not designed to be adjusted.
- During installation or de-installation, it is imperative to protect the device from building an electrostatic charge on its surface.
- The device is designed for fixed mounting.
Device Anatomy
Your volumetric Meter kit will contain the following items:
- a. One pulsar adapter
- b. One front seal
- c. One rear seal
- d. Four 1/4-20 x 2″ screws
THE INSTALLATION OF THIS DEVICE IS RESERVED ONLY FOR PROPERLY TRAINED PERSONNEL AND MUST BE APPROVED BY THE SAFETY BODY HAVING JURISDICTION.
IMPORTANT
FOR FIELD INSTALLATIONS, ENSURE TO SHUT OFF THE MAIN GAS VALVE BEFORE
ATTEMPTING ANY WORK!
Installation Instructions
-
Inspect for safety concerns
- a. IMPORTANT Turn off the flow of gas. Ensure ALL equipment using gas is secured.
- b. Remove any debris, dirt, or other contaminants from the area of the gas meter register.
- c. Carefully inspect the device for possible safety concerns such as a leak (or any other issue that could compromise safety).
- DO NOT proceed if anything concerning is found. Report immediately.
-
Remove screws
Remove all four screws using a slotted screwdriver then carefully pry off the transparent cover.- If a lock seal is attached to the gas meter screws, ensure you have permission to remove it before proceeding.
- You may also be required to break a seal on a bolt.
-
Remove register
Proceed to remove the two small screws that secure the register in place. Then, carefully detach the device. Ensure you do not let the register or screws to fall. -
Clean interior
Clean the interior area. -
Determine axle compatibility
Identify the gas meter’s axle type:- Female (Oblong hole) or b. Male (Square tab).
- Front side: Otodata’s Volumetric Meter can mate with both female and male axles. It has a prong that can be mated with the oblong hole (female), and, 5 cavities in the wheel where the square tab (male) can be inserted.
- Back side: Similarly, the Volumetric Meter can mate with both female and male axles.
-
Activate device
To activate the device, spin the wheel at least three times. The device will wake up and start looking for a connection automatically. -
Reinstall register
- Attach the register to the Volumetric Meter.
- Use special care to properly mate the register’s axle with the wheel. You may turn the wheel to adjust the alignment.
- Secure the register in place using the two screws previously removed.
-
Assemble device components
Assemble all components forming a single piece.- a. Rear seal
- b. Pulse adapter
- c. Front seal
- d. Transparent cover
- e. 1/4-20 x 2″ screws.
-
Attach to the gas meter
Attach the assembled device to the gas meter.- Take special care to ensure the axles couple correctly.
-
Secure with screws
Using a Nonsparking slotted screwdriver, gently screw the device in place. DO NOT over-tighten. -
Inspect installation
- Ensure everything is correctly installed.
- Then, open the shut valve and check for any leaks near the index or the surroundings.
Members can watch step-by-step installation videos and shop online
Sign up free today at otodatatankmonitors.com/membership.
Members can purchase monitors and accessories like gauges, leads, mounting equipment, and more via our online store.
IMPORTANT
Please take a moment to carefully read the installation instructions included
with your monitors, and ensure you understand and respect local regulations.
-
ABOVE-GROUND TANKS
Do not install monitors under lids. -
UNDERGROUND TANKS
- A plastic lid is suggested.
- Metal lids will obstruct the signal.
Reading installation instructions will ensure maximum monitoring performance on all your tanks and installations.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>