QUEEN CHOOSE XTY-D-1 LittleSun Warming Device Instruction Manual
- July 21, 2024
- QUEEN CHOOSE
Table of Contents
QUEEN CHOOSE XTY-D-1 LittleSun Warming Device
Introduction
Product Overview
This product employs the principles of moxibustion technology. By extracting the medicinal properties of mugwort at high temperatures and controlling wind speed, it directs these properties to the human body. This process helps to “unblock meridians, warm channels, and replenish yang energy.” It effectively soothes tense nerves, alleviates stress, and reduces the fatigue accumulated throughout the day。
Technical Specifications
Product Name: | Little Sun Warming Device |
---|---|
Model Number: | XTY-D-1 |
Rated Voltage: | 100~240V AC |
Rated Power: | 180W |
Product Weight: | 3.55 KG |
Package Dimensions: | 45 x 21.5 x 16.5 cm |
Application Scenarios: | Home, Beauty Salon, Wellness Center |
Suitable for
Suitable for most people (not recommended for pregnant women, individuals with congenital diseases, or those with heart conditions).
Installation And Setup
Installation
-
Upon receiving the instrument, first check if the outer packaging is damaged.
If so, please contact the manufacturer’s customer service promptly. -
Remove the instrument from the packaging and check against the appendix for any missing parts. If there are any, please contact the manufacturer’s after-sales service promptly.
-
After taking out the instrument, unravel the power cord, open the legs on both sides, and place the instrument on a flat surface.
-
Adjust the height as needed by extending or retracting the legs on both sides.
Setup
- Insert the power plug into the socket and turn on the power switch of the instrument.
- Take the IC card from the product set, place it in the IC card recognition area, and upon hearing a beep, the card’s count is imported into the instrument.
- The instrument’s display screen will show the remaining number of uses
Operating Instructions
-
First Step: Instrument Check: Open the outer packaging and check if the instrument is intact. If there is any damage, please contact the authorized dealer for resolution.
-
Second Step: Load Consumables: Place the consumables in the consumable box.
( Note : When placing consumables in the box, compress the consumables tightly, then cover the lid.) Open the lid of the consumable compartment on the instrument (turn counterclockwise to open), place the consumable box inside (turn clockwise to close). -
Third Step: Plug in the Power: Insert the plug into the socket and turn on the power switch on the side of the main unit.
-
Fourth Step: Import Card: After powering on the main unit, the screen will display “Swipe Card.” Take the IC card from the product set, place it in the card swipe area on the main unit, and upon hearing a beep, the card’s count is imported into the main unit, and the screen shows “Remaining xx Uses.”
-
Fifth Step: Start the Instrument: Press the start button on the main unit’s panel, the instrument starts, displays “Remaining 45 minutes,” and the countdown begins.
-
Sixth Step: End of Use: After 45 minutes of normal use, the instrument will end this session, the main unit screen will display “End,” but keep the instrument powered on for 5 minutes to allow it to cool down before turning off the power.
Warm Tips:
-
This instrument requires the company’s IC card to start. The IC card is included in the product set, and the usage count matches the product set.
-
Each use lasts 45 minutes. If you need to pause, you can briefly press the “Pause” button.
To change the time, you can briefly press the “Time” button to decrease the time. -
If the remaining time is not enough to finish, the remaining time can be used the next time the instrument is started.
-
If the temperature is not sufficient, you can briefly press the “Temperature” button to adjust to a suitable temperature. The adjustment order is “Medium-High-Low.”
Safety Precautions
- Avoid moxibustion when overly hungry, overly full, intoxicated, extremely frightened, extremely angry, extremely thirsty, overly fatigued, or mentally tense. Weak individuals should also avoid moxibustion.
- Do not use the instrument within an hour after meals. Do not wash hands or bathe with cold water within half an hour after moxibustion.
- Drink warm water after moxibustion, and avoid cold or iced water.
Maintenance and Care
- Operate according to the manual.
- Do not use the instrument continuously without a 10-minute break between sessions.
- Turn off the instrument 5 minutes after use and unplug the power cord to ensure safety.
Fault Status: | Check Method |
---|---|
Power switch is on but the display if off: | Check if the power plug is |
properly connected
Check if the power socket has electricity
Instrument buttons are not responsive| Button sensor contact is faulty;
contact manufacturer
IC card cannot be imported:
| Replace with a new IC card or restart the instrument
Check if the IC card’s count is used up; Confirm using the card verification
function
Instrument body is overheating| Use time is too long; Turn off and let it cool
naturally
Check if the power voltage meets the requirements
Appendix
Product Accessories
- Main Unit x1
- Main Unit x1
- Tweezers x1
- Mugwort Box x2
Nationwide After-Sales Maintenance Phone
180-1170-4039
After-Sales Service Center Address
7th Floor, Building 10, 16 Changbao East Road, Ronggui, Shunde Tianfulai International Industrial City, Foshan, Guangdong
NFC function use: Use the IC card to identify and start the operation of NFC equipment
Declaration
Special announcement: This product is not a medical device, for the heating of
the hot compress electrical appliances, electrical appliances, general
international GB4706.1-2005 and electric heat class special standard GB
4706.15-2008, the above page is only to place the Ai cake as an example, but
also can be placed in the ginger and other substances or do not put any
substances for the hot compresses, the page contained in the human body to
relieve the function of the enhancement of the role of the descriptions of the
relevant literature for the hot compresses as well as the Please note that the
descriptions of human function relief and enhancement contained in the pages
are from the relevant literature on hot compresses and moxibustion research,
please note that consumers.
This instrument has passed the GB4706-1-2005 quality inspection standard and
meets safety specifications.
FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning : changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment
The devices has been evaluated to meet general RF exposure requirement, the
device can be used in portable exposure condition without restriction.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>