KOHLER Archer K-1124-XGHRA Alcove Heated BubbleMassage Air Bath and Whirlpool Right Drain Owner’s Manual

July 12, 2024
Kohler

KOHLER Archer K-1124-XGHRA Alcove Heated BubbleMassage Air Bath and

Whirlpool Right Drain

Specifications

  • Product Name: 72 x 36 alcove Heated BubbleMassageTM air bath and whirlpool, right drain K-1124-XGHRA
  • Massage Features : Surround and support the body in a warm massage, adjustable BubbleMassageTM intensity levels, customizable hydromassage flow and direction at each jet
  • Material: Hydrotherapy Technology
  • Installation: Simplifies alcove installation, right drain
  • BubbleMassageTM Technology: Experience for 60 minutes, air switch actuator for whirlpool
  • Codes/Standards: ASME A112.19.7/CSA B45.10, CSA B45.5/IAPMO Z124, ASTM E162, ASTM E662, UL 1795, CSA C22.2 No. 218.2, ADA, ICC/ANSI A117.1, IAPMO Certification cUL Listed, UL Listed

Product Usage Instructions

Ensure three dedicated circuits are available, protected with Class A Ground- Fault Circuit-Interrupter (GFCI). Follow specific measurements and instructions for rough-in. Install the product according to the provided installation guidelines.

Pump, Heater, and Blower require 120 V, 15 A, 60 Hz electrical service. Ensure the hot water supply meets the capacity requirements. For outside North America, follow local regulations for electrical installations.

  • Drain Location: Right
  • Water Capacity: 72 gal (272.5 L)
  • Electrical Component Ratings: Pump – 120 V, 7 A, Heater – 120 V, 5 A, Heater – 120 V, 12 A, Heater – 120 V, 10 A
  • Basin Area: Bottom – dimensions provided in manual, Top – dimensions provided in the manual
  • Weight: As per specifications
  • Minimum Floor Load: As per specifications
  • Water Depth: As per specifications

FAQ

  • Q: Can I relocate the blower in the product?
  • A: Do not relocate or alter the PVC tee or coiled flexible tubing connected to the blower. Follow the blower relocation instructions exactly to maintain product integrity.
  • Q: What electrical service is required for the product?
  • A: The Pump, Heater, and Blower require 120 V, 15 A, 60 Hz electrical service. Ensure compliance with local electrical regulations.
  • Q: Is the product ADA-compliant?
  • A: The product is ADA-compliant when installed following the specific requirements outlined in the regulations.

Features

  • 118 airjets release thousands of heated bubbles that surround and support the body in a warm massage
  • Automatic and manual purge cycles remove residual water from air channels after use
  • Variable-speed blower lets you adjust Heated BubbleMassage™ massage intensity to 18 levels
  • Single-speed whirlpool revitalizes sore muscles
  • 8 fully adjustable whirlpool jets allow users to customize hydromassage flow and direction at each jet
  • Comfort Depth® design offers a convenient 19″ step-over height while retaining the same depth as a standard 21″ bath
  • Integral lumbar support
  • Slotted overflow allows for deep soaking
  • Integral apron
  • Integral flange helps prevent water from seeping behind wall and simplifies alcove installation
  • Textured bottom surface
  • Coordinates with other products in the Archer collection
  • Built-in 600W BubbleMassage™ heater warms humidified air before it enters the bath
  • Automatic and manual purge cycles remove residual water from air channels after use

Material

  • Acrylic

Hydrotherapy

  • Whirlpool

Technology

  • The auto-shutoff timer on the blower allows users to enjoy the Heated BubbleMassage™ experience for 60 minutes before turning off
  • User interface: electronic keypad control for Heated BubbleMassage™; air switch actuator for whirlpool

Installation

  • Right drain

Required Products/Accessories

  • K-7271 Brass Slotted Overflow Bath Drain
    or

  • K-7272 PVC Slotted Overflow Bath Drain

Recommended Products/Accessories

  • K-23726 Drain treatment
  • K-23732 Tub & shower cleaner
  • K-31797 Slotted overflow bath drain kit
  • K-31795 Slotted overflow above-the-floor bath drain kit

Codes/Standards

  • ASME A112.19.7/CSA B45.10
  • CSA B45.5/IAPMO Z124
  • ASTM E162
  • ASTM E662
  • UL 1795
  • CSA C22.2 No. 218.2
  • ADA
  • ICC/ANSI A117.1
  • IAPMO Certification
  • cUL Listed
  • UL Listed

KOHLER® Plastic Baths and Shower Bases Lifetime Limited WarrantyKOHLER® Hydrotherapy Components Five-Year Limited Warranty

  • See the website for detailed warranty information.

Available Colors/Finishes

  • Color tiles are intended for reference only.

Color Code Description

  • 0 White
  • 96 Biscuit
  • NY Dune
  • 95 Ice™ Grey
  • 58 Thunder™ Grey
  • 7 Black Black™

Dimension

Required Electrical Service

  • Three dedicated circuits are required, protected with Class A
  • Ground-Fault Circuit-Interrupter (GFCI). Outside North America, this device may be known as a Residual Current Device (RCD).
  • Pump, Heater: 120 V, 15 A, 60 Hz
  • Heater: 120 V, 15 A, 60 Hz
  • Blower: 120 V, 15 A, 60 Hz

Technical Information

All product dimensions are nominal.

  • Drain location: Right
  • Basin area, bottom: 51-3/8″ x 21″ (1305 mm x 533 mm)
  • Basin area, top: 64-1/2″ x 30-1/2″ (1638 mm x 775 mm)
  • Weight: 165 lbs (74.8 kg)
  • Minimum floor load: 44.2 lbs/ft² (215.8 kg/m²)
  • Water depth: 15″ (381 mm)
  • Water capacity: 72 gal (272.5 L)
  • Electrical component rating:
  • Pump: 120 V, 7 A, 60 Hz
  • Heater: 120 V, 5 A, 60 Hz
  • Heater: 120 V, 12 A, 60 Hz
  • Blower: 120 V, 10 A, 60 Hz

Notes

  • Measure your actual product for rough-in details.
  • Install this product according to the installation instructions.
  • The hot water supply should be 70% of the capacity of the bath or greater. Installations will vary.
  • A remote blower installation kit is available for relocating the blower. Provide access for servicing the blower.
  • Do not relocate or alter the PVC tee or coiled flexible tubing connected to the blower. Follow the blower relocation instructions exactly.
  • ADA-compliant when installed to the specific requirements of these regulations.

CONTACT

  • 1-800-4KOHLER (1-800-456-4537)
  • Kohler Co. reserves the right to make revisions without notice to product specifications.
  • For the most current Specification Sheet, go to www.kohler.com USA or www.kohler.ca Canada
  • 6-19-2024 20:09 – US

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals