Schneider Electric BLE Iconic Connected AC Fan Speed Controller User Guide

July 10, 2024
Schneider Electric

Schneider Electric BLE Iconic Connected AC Fan Speed Controller

Product Information: Iconic Connected AC Fan Speed Controller BLE

Specifications

  • Device Type: AC Fan Speed Controller
  • Connectivity: Bluetooth Low Energy (BLE)
  • Manufacturer: Schneider Electric
  • Brand: Iconic

Product Usage Instructions

Safety Information
Before using the Iconic Connected AC Fan Speed Controller, read and familiarize yourself with the safety information provided in the manual. Make sure to follow all safety instructions to avoid potential hazards.

Installation

  1. Locate a suitable location near the AC fan for installing the speed controller.
  2. Turn off the power supply to the AC fan before installation.
  3. Follow the wiring diagram provided in the manual to connect the speed controller to the AC fan.
  4. Securely mount the speed controller in place using appropriate tools.

Operation

  1. Power on the AC fan and the speed controller.
  2. Use the BLE connectivity to pair the speed controller with your smartphone or compatible device.
  3. Adjust the fan speed using the control options available on the connected device.

Maintenance
Regularly inspect the speed controller for any signs of damage or wear. Clean the device as needed using a soft, dry cloth. Do not use any harsh chemicals or abrasive materials for cleaning.

FAQ

  • Q: Can I use the Iconic Connected AC Fan Speed Controller with any type of AC fan?
    A: The speed controller is designed to work with compatible AC fans. Refer to the manual or contact customer support for compatibility information.

  • Q: How do I reset the speed controller?
    A: To reset the speed controller, turn off the power supply, wait for a few seconds, and then power it back on. Refer to the manual for specific reset instructions.

Iconic Connected AC Fan Speed Controller BLE

Device user guide
Information about features and functionality of the device.
06/2024

Legal Information

The information provided in this document contains general descriptions, technical characteristics and/or recommendations related to products/solutions.
This document is not intended as a substitute for a detailed study or operational and site-specific development or schematic plan. It is not to be used for determining suitability or reliability of the products/solutions for specific user applications. It is the duty of any such user to perform or have any professional expert of its choice
(integrator, specifier or the like) perform the appropriate and comprehensive risk analysis, evaluation and testing of the products/solutions with respect to the relevant specific application or use thereof.
The Schneider Electric brand and any trademarks of Schneider Electric SE and its subsidiaries referred to in this document are the property of Schneider Electric SE or its subsidiaries. All other brands may be trademarks of their respective owner.
This document and its content are protected under applicable copyright laws and provided for informative use only. No part of this document may be reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), for any purpose, without the prior written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the document or its content, except for a non-exclusive and personal license to consult it on an “as is” basis.
Schneider Electric reserves the right to make changes or updates with respect to or in the content of this document or the format thereof, at any time without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by Schneider Electric and its subsidiaries for any errors or omissions in the informational content of this document, as well as any non-intended use or misuse of the content thereof.

Safety Information

Important Information

Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of either symbol to a “Danger” or “Warning” safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that accompany this symbol to avoid possible injury or death.

DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Failure to follow these instructions will result in death or serious injury.

WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE
NOTICE is used to address practices not related to physical injury.

Iconic Connected AC Fan Speed Controller

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(2\)

For your safety

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • It is illegal for persons other than an appropriately licensed electrical contractors or other persons authorised by legislation to work on the fixed wiring of any electrical installation.
  • To comply with all safety standards, the device must be used only for the purpose described in this instruction and must be installed in accordance with the wiring rules and regulation in the location where it is installed.
  • Lock out and tag the input circuit before accessing the wiring connections.
  • The Locking Bar on the grids must be set to the Closed position to ensure that the device cannot be removed during normal operation.
  • There are no user serviceable parts inside the device.
  • Failure to follow these instructions will result in death or serious injury.

NOTICE
EQUIPMENT DAMAGE HAZARD (LOAD AND OPERATION)

  • Operation of the device at elevated temperatures or voltages outside of specification (240 V A.C. and 25 °C) may cause the over-temperature protection circuitry to operate.
  • Reduce the size of the connected load or use a different brand of fan to prevent recurrence.
  • Do not operate the product for prolonged periods in extreme conditions. Failure to follow these instructions can result in equipment damage.

About the device
Iconic Connected AC Fan Speed Controller, Bluetooth (hereinafter referred to as fan controller) can control up to two fans and in three steps, you can adjust the fan speed to achieve your desired comfort. You can also control the fan using Wiser app.
Connect the fan controller directly to your mobile device via Bluetooth.

Operating elements

  • A. Push-button
  • B. Status LED (Amber, Green, and Red LED)
  • C. Speed indicating LEDs

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(3\)

NOTE:

  • The LED position will change when the fan controller is installed in a different orientation. To maintain same LED position with change in orientation, refer to the orientation settings.
  • For information on LED during each control stage, refer LED indication, page 16.

Installing the device
Refer to the installation instruction supplied with this product. See Connected AC Fan Speed Controller, BLE.

Pairing the device manually
Using the Wiser app, you can pair the device with smartphone to access and control the device.

NOTE: When pairing the Bluetooth™ device with the Wiser app, be within a range of 8 to 10 m of the module. Range can be affected by wall thickness and construction materials.

  1. On Home page, tap + then tap Iconic A.C. fan controller BLE *
  2. Press and hold the push-button for > 8 s to enter pairing mode. LED blinks red/green per second
  3. In the app, select Confirm the indicator blinking rapidly and tap Start Configuration (A). NOTE: Enable permissions to nearby devices and Bluetooth™ for scanning the device.
  4. Tap  to select and add the device from the list and then tap Next > Done.
    NOTE: The device can be paired with max. 8 smartphones. To pair an additional phone, you must unpair one of the existing phones. Refer managed paired phones, page 12.

Manual operation

You can turn on/off or control the fan speed manually.
Shortly press the push button to turn on the fan at low speed, then press it again to change the speed to medium and then again to high.
Press and hold the push-button for 1 s to turn off the fan.
You can also turn off the fan by short pressing the push button once when it is at high speed.

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(7\)

Configuring the device

Changing the device icon
You can change the device icon using the Wiser app.

  1. On the Home page, select the device for which you wish to change the icon.
  2. At the top-right corner of the screen, tap
  3. Tap edit next to the device name.
  4. Tap Icon to view the menu.
  5. In the slide-up menu, select any one of the following (A) to change the device icon:
    • Take photo – allows you to take a photo with your device camera.
    • Select from Icon Library – allows you to select an icon from the app library.
    • Select from Album – allows you to select a photo from the mobile gallery.

Renaming the device
You can rename the device using the Wiser app.

  1. On the Home page, select the device for which you wish to rename.
  2. At the top-right corner of the screen, tap
  3. Tap edit next to the device name.
  4. Tap Name, enter the new name (A) and then tap Save.

Changing the device location
You can change the device location using the Wiser app.

  1. On the Home page, select the device for which you wish to change the location.
  2. At the top-right corner of the screen, tap
  3. Tap edit next to the device name.
  4. Tap Location.
  5. Select the desired location from the list (A) and then tap Save.

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(13\)

Fan controller settings

Using The Wiser app, you can manage the Dimmer modes and settings.

  1. On the Home page, tap All devices > Iconic Fan Controller.
  2. Tap Settings and select any of the following:

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(8\)

Changing the Mode
Using mode setting, timer can be set to turn off the device after a set period of time or you can set it as a switch to turn on/off manually.
On the Settings page, tap Mode and select any of the following:

  • Switch : control the speed and turn on/off of the fan.
  • Timer : when fan is running, set the timer to turn off. Refer using mode timer, page 14.

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(14\)

LED Indicator Settings

You can select the LED indicator mode for easy identification of the device status.
On the Settings page, tap LED Indicator Settings and select any of the following:

  • Always On: LED on the device is always turned on.
  • On with Timeout but as Locator: LED glow in lesser brightness after the time out.
  • On with Timeout: After inactive period LED turns off.

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(15\)

Synchronization Time

Using Wiser app, you can synchronize the time of the device with your smartphone.
On the Settings page, tap Synchronization Time > Update Time & Date (A). This allows the device time to sync with smartphones in real-time.

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(16\)

Manage Paired Phone

Using Wiser app, you can view or delete paired phones.
On Settings page, tap Manage Paired Phone and select any of the following (A):

  • Delete all Devices: the device is removed from all paired phones.
  • Delete my Device: the device is removed from current phone.

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(17\) Device Orientation
The Fan Controller can be installed in 4 different orientations. This feature allows the user/installer to select the orientation of the low/medium/high speed LEDs to maintain the same sequence across different fan controllers.

On the Settings page, tap Device Orientation and select any of the following:

  • Horizontal Left
  • Horizontal Right
  • Vertical Top
  • Vertical Bottom

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(18\)

Reset device settings
Using Wiser app, you can reset the device settings to default.
On Settings page, tap Reset device settings.
Read the information and tap Confirm (A).

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(19\)

NOTE: This action will reset the device to default factory settings.

Using the Device
On the Home page, tap All devices > Iconic Fan Controller to access the control panel.
On the fan controller control panel page, you can see the following:

  • Power button (A)
  • Fan speed (B)
  • Mode timer, page 14 (C)
  • Mode indicator, page 11 (D)
  • Settings (E)

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(20\) Operating the device using app

Using the Wiser app, you can turn on/off and regulate the fan speed.

  1. On Home page, select the fan controller and tap power button (A) to turn on/off the fan.
  2. Once fan is turned on, select the required speed (B).Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller- \(21\)

NOTE: During timer mode, the fan controller automatically turns off after a specified period of time. Refer Using timer mode, page 14.

Setting timer mode
You can set the timer to turn off the device after a certain period of time.
In Wiser app, change the mode from switch to timer, refer to mode settings, page 11.

  1. On the device control panel page, tap timer (A) for the slide-up menu.
  2. Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller- \(22\)In the slide-up menu select the required Set Period (B) and tap Save.Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller- \(23\)

NOTE: The timer mode will be stopped automatically at the end of the countdown timer. If the timer mode feature is enabled, and there are one or more Schedule/Moment/Automation actions in this period, then the system will stop the current mode action immediately, and perform the new actions (the new action always has a higher priority than the current action).

Once the countdown timer reaches zero, the device turns off.

Removing the device

Using the Wiser app, you can remove a device from the device list.

  1. On the Home page, tap All devices > Iconic Fan Controller.
  2. Tap to display more details.
  3. Tap Remove device (A) and select any of the following:
    • Disconnect: to remove the device.
    • Disconnect & Erase Data: to remove the device and erase data.

TIP: On the Home page, tap and hold the Iconic Fan Controller to remove the device.

Resetting the device manually
You can reset the device to factory default manually.
Short press the push button three times (<0,5 s) and then long press the push button once (>10 s).
After 10 s, release the push button when the LED starts blinking red .Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(24\)

LED indication

Pairing the device

User Action LED Indication Status
**** Press and hold the push button for > 8 s times. **** LED blinks red
green. Pairing mode is active for 30 seconds. When pairing is completed, LED

glows green for a few seconds before turning Off.

Resetting the device

User Action LED Indication Status
Short press the push button 3 times and hold it down once for > 10 s. LED
blinks red once per second. The device is reset to the factory settings after

10 seconds and the device turns off.

LED indicator mode

LED indicator mode Speed LEDs Timeout **Locator***
**** Always On Low LED1 ****

0

| ****

No

Medum| LED1 and LED2
High| LED1, LED2, and LED3
Off| LED1, LED2, LED3, and LED4



Act as a Locator

| Low| LED1| ****

5 s

| ****

Yes

Medum| LED1 and LED2
High| LED1, LED2, and LED3
Off| LED1, LED2, LED3, and LED4



On with Timeout

| Low| LED1| ****


5 s

| ****


No

Medum| LED1 and LED2
High| LED1, LED2, and LED3
Off| LED1, LED2, LED3, and LED4
*Glows all four LEDs in lesser brightness after the time out

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(29\)

Troubleshooting

Symptom Solution
No fan movement or uncontrolled movement.
  • Check power supply.
  • Check the wiring.
  • Check the load

The device is not ready to pair after the device is removed from the app.| Reset to factory default settings, refer to resetting the device manually, page 16.

Technical Data

Technical data

Operating Voltage 220 – 240 V AC. , 50 Hz
Load rating Total max.150 W
Number of Fans Max. 2
Switching Technique Relay

Protection

Over Temperature Yes
Short circuit No
Over-current fuse No
Thermal protection Yes
LED Indicator Yes
Multi-gang plate capacity Max 3 primary fan controllers per plate
Compatible plate ranges Iconic, Iconic Style, Iconic Essence, Pro Series
Mounting Centres 84 mm pattern plate
Environmental Rating IP20

Ambient operating

Humidity 5%–90% RH, non-condensing
Temperature -10 to +50 °C

41ECSFWM-VW

Communication protocol Bluetooth low energy

Compliance

Product certification **** RCM
Safety AS/NZS 60669.2.1
EMC AS/NZS 60669.2.1
RF AS/NZS 4268, AS 2772.2

Compliance

Compliance information for Green Premium products
Find and download comprehensive information about Green Premium products, including RoHS compliance and REACH declarations as well as Product Environmental Profile (PEP) and End-of-Life instructions (EOLI). https://checkaproduct.se.com/

General information about Green Premium products
Click the link below to read about Schneider Electric’s Green Premium product strategy.
https://www.schneider-electric.com/en/work/support/green-premium/

Schneider-Electric-BLE-Iconic-Connected-AC-Fan-Speed-Controller-
\(32\) Trademarks
This guide makes reference to system and brand names that are trademarks of their relevant owners.

  • Bluetooth® is a registered trademark of the Bluetooth Special Interest Group (SIG).
  • Apple® and App Store® are brand names or registered trademarks of Apple Inc.
  • Google Play™ Store and Android™ are brand names or registered trademarks of Google Inc.
  • Wi-Fi® is a registered trademark of Wi-Fi Alliance®.
  • Wiser™ is a trademark and the property of Schneider Electric, its subsidiaries and affiliated companies.

Other brands and registered trademarks are the property of their respective owners.

Schneider Electric (Australia) Pty Ltd
33-37 Port Wakefield Road
Gepps Cross SA 5094
Australia
Customer Care: 13 73 28
www.clipsal.com
As standards, specifications, and design change from time to time, please ask for confirmation of the information given in this publication.
© 2024 – 2024 Schneider Electric. All rights reserved.
DUG_AC Fan Controller_Pacific_WSE-00

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals