SUNMAX RT35 Hand Pushed Floor Scrubber
Product Information
Specifications
- Brush disc diameter: 17 inches
- Squeegee width: 22 inches
- Cleaning efficiency: 19000 sq ft/h
- Brush plate motor speed: 155 rpm
- Brush motor power: 300W
- Suction motor power: 500W
- Machine voltage: 24V
- Clean water tank capacity: 7.9 gallons
- Sewage tank capacity: 9.2 gallons
- Battery charging time: 8-10 hours
- Battery life: 2-2.5 hours
- Battery rated voltage: 12V/45Ah
- Machine net weight: 132 lbs
- Machine gross weight: 232 lbs
- Machine size (L x W x H): 55.1 x 23.2 x 43.3 inches
- Packing box size (L x W x H): 39.8 x 22.8 x 38.2 inches
Product Usage Instructions
Machine Performance and Uses
The RT35 Hand-Pushed Floor Scrubber is a floor cleaning machine that utilizes
the mechanical friction of brush plates along with chemical cleaning agents.
It is suitable for cleaning various types of floors, with dirty materials and
water being sucked dry by the rear squeegee. To ensure efficient operation, it
is essential to use and maintain the machine correctly.
Machine Delivery
Upon receiving the machine, carefully check if all items listed in the packing
list are included and inspect for any damages incurred during transportation.
In case of damage, count the types and quantities of damaged items with the
freight agent and notify the after-sales service department for prompt
resolution.
Meaning of Warning Symbols
Various warning symbols are provided for safety precautions. Be cautious of
evaporating gases, corrosive substances, ignition sources, and other potential
hazards. Always read and follow the user manual for safe operation.
FAQ
Q: What should I do if the machine exceeds its rated load capacity?
A: Do not use the machine beyond its rated load capacity to avoid damage to components.
Q: How can I ensure the longevity of the battery?
A: Follow the recommended charging time and avoid overcharging to prolong battery life.
Q: Can I use the machine in extreme environments?
A: Avoid using the machine in extremely harsh environments like acidic or alkaline conditions to prevent damage or accidents.
Machine Performance and Uses
This machine is a floor cleaning machine that combines mechanical friction of
brush plates with chemical cleaning agents. It is suitable for cleaning
various types of floors, and dirty materials and water on the floor are sucked
dry by the rear squeegee. As long as you use and maintain the machine
correctly, any of our products can operate efficiently and effectively.
Machine Delivery
When the machine is delivered to the customer, the customer should immediately
check whether the received items match the packing list. Then carefully
inspect whether any items have been damaged during transportation. If any
damage has occurred, the customer should immediately count the types and
quantities of damaged items with the freight agent and notify our after-sales
service department. This is the fastest way to compensate for your losses.
Packing List
Number | Name | Unit | Quantity |
---|---|---|---|
1 | Main Machine | Piece | 1 |
2 | Charge | Set | 1 |
3 | Squeegee Assembly | Set | 1 |
4 | Brush (pre-installed on the machine) | Piece | 1 |
5 | Pad Holder | Piece | 1 |
6 | Scrubbing Pad | Piece | 1 |
7 | Battery Connection Cable | Piece | 1 |
8 | Manual Book | Piece | 1 |
Performance Parameters
category | parameter | category | parameter |
---|
Brush disc
diameter
| 17 inches| Sewage tank capacity| ****
9.2 gallons
Squeegee width| 22 inches| Lead acid battery charging
time
| ****
8~10h
cleaning efficiency| 19000 sq ft/h| Battery life| 2~2.5h
Brush plate motor
speed
| 155 rpm| Battery rated voltage| ****
12V/45Ah
Brush motor
power
| 300W| Machine net weight| ****
132 lbs
Suction motor
power
| 500W| Machine gross weight| ****
232 lbs
Machine voltage| 24V| Machine size (length x width x
height)
| ****
55.123.243.3 inches
Clean water tank
capacity
| 7.9 gallons| Packing box size (length x
width x height)
| ****
39.822.838.2 inches
Meaning of Warning Symbols
Warning
- For the safety of operators and the machine, it is necessary to carefully read all content marked with these symbols before use.
- Be cautious of evaporating gases and corrosive substances that may spill. Keep the machine away from ignition sources.
For this reason, we recommend that you carefully read this user manual before use, and we hope that you will read it again if the machine experiences operational issues. Our service department will also provide you with appropriate advice and necessary assistance.
Disclaimer
- Before use, carefully read and verify the power supply size indicated on the nameplate, and confirm that the current power supply meets the requirements of this product. The company shall not be liable for any damage to the product or personal injury caused by incorrect use of the power supply.
- Do not use the machine beyond its rated load capacity. The company shall not be liable for any damage to components caused by this.
- Do not use the machine in extremely harsh environments (acidic, alkaline, excessively low or high temperatures). The company shall not be liable for any damage, accidents, or injuries caused by this.
- The company shall not be liable for malfunctions and damage caused by failure to use, maintain, or store the machine according to the instructions, or by foreign objects entering the machine.
- The company shall not be liable for damage or injuries caused by unauthorized modification of the floor scrubber.
Machine Usage Precautions
- Please read the labels on the machine carefully. Under no circumstances should they be covered, and if damaged, they should be replaced immediately.
- This machine should only be operated by authorized and trained personnel.
- When the machine is in operation, please pay attention to the safety of other individuals, especially children.
- Never mix two types of cleaning agents, as this may produce harmful gases.
- Do not load the machine into a container when residual liquid is present.
- The storage temperature of the machine must be between -25°C and 55°C.
- Operating conditions for the machine: room temperature from 0°C to 40°C; air humidity from 30 to 95.
- Never use this machine in explosive environments.
- Prohibited from using this machine to transport items.
- Prohibited from using acidic solutions to avoid damaging personnel and the machine.
- Avoid running the brush plate when the machine is stationary, as this may damage the floor.
- Prohibited from using flammable liquids.
- This machine is not suitable for cleaning hazardous waste.
- In the event of a fire in the machine, please use a dry powder fire extinguisher; do not use water.
- Do not operate near shelves or scaffolding with falling hazards.
- Select the appropriate operating speed based on traction conditions.
- To prevent instability, it is prohibited for the machine to operate on slopes exceeding the allowed conditions.
- When parking the machine, remove the key and place it on a flat surface.
- The machine must simultaneously clean and dry the floor. Any unauthorized operation by personnel is strictly prohibited. Wet and slippery floors should have appropriate warning signs.
- Whenever the machine experiences operational issues, first confirm whether it is due to insufficient daily maintenance; if not, please contact the nearest help centre for assistance.
- When replacing parts, be sure to request genuine parts from authorized agents or retailers.
- Please use only genuine brush plates according to the “Selection and Use of Brush Plates” guidelines.
- In the event of danger during operation, the power should be shut off immediately.
- Disconnect the power supply before cleaning and maintenance.
- Note: after any maintenance, restore all electrical connections.
- Protective devices must be dismantled using specialized tools.
- Prohibited from washing the machine directly with corrosive agents or high-pressure water.
- To prevent detergent from condensing on the freshwater tank filter, it is strictly forbidden to add detergent to the machine hours before use.
- Before using the machine, make sure to install all covers and lids according to this manual.
- Before moving the wastewater tank, ensure that the water has been drained.
- When handling consumables, strict compliance with local laws is required.
- After several years of efficient use, our machines may become obsolete. Dispose of oil, batteries, and electrical components in the machine carefully. Remember, all components of this machine are made of renewable materials.
Preparation and Configuration of the Machine Preparation before Unboxing
- This machine is packaged in a specially designed wooden crate, which can be handled with a forklift. The machine can only be placed in two layers.
- The dimensions of the packaging box are as follows: Length: L=39.8 inches, Width: W=22.8 inches, Height: H=38.2 inches.
- Opening the Outer Packaging Box
- The machine is secured to a fixed frame on a wooden pallet.
- Remove the fixed frame
- Remove the machine along with the wooden pallet.
- You can also keep the wooden pallet for future transportation.
Machine Introduction
- A: Handle
- B: Key Switch
- C: Battery Level Display
- E: Brush Switch
- F: Drain Pipe Plug
- G: Filter
- H: Suction Switch
- I: Solenoid Valve
- J: Adjustment Nut
- L: Battery Cable
- N: Water Valve Adjustment
- P: Suction Inlet
- Q: Suction Squeegee Bracket
- R: Clean Water Tank Filter
- S: Drain Pipe
- T: Suction Tube
- U: Dirty Water Tank Lid
- V: Dirty Water Tank
- W: Battery Plug (Male)
- X: Clean Water Tank
- Y: Suction Squeegee
- Z: Battery
Battery charging connection (see image below)
Connect the battery charger to the battery plug, the battery charger and this
manual are placed in the same box, and must be connected to the charger
according to the relevant instructions.
This connection should be made by specialized personnel, any wrong or incomplete connection will result in damage to the machine and personnel.
Maintenance of the battery
- The battery should be charged and maintained in strict accordance with the instructions of the battery manufacturer.
- Special attention should be paid to the selection of battery chargers, which should be selected according to the different types and capacities of the battery.
- The new battery should be fully charged before first use. It can be used for 5 deep charges and deep discharges of the new battery
Battery disposal
When the battery life is exhausted, the connection should be cut off by a
special person and correspondingly removed from the battery compartment.
- Batteries are hazardous wastes and should be disposed of in a timely manner after the storage is exhausted. Please comply with local regulations for waste disposal.
Battery charging
In order to avoid permanent damage to the battery, remember not to drain all
the battery charge, and to do so, charge it within a few minutes of noticing
that the battery alarm light starts flashing.
Note:
Never drain all the battery charge, even when the machine is no longer in use.
When charging, lift the sewage tank and secure it with a bracket as shown in
the figure on the right, and make sure that the charger corresponds to the
type and capacity of the battery used.
- Beware of electric shocks
- Beware of evaporating gases and spilling corrosive media.
- Beware of fire prevention: Please keep away from the machine.
Battery charge status indicator
The battery charge status display has 10 LED light bar displays, and 3 light bar colours, and these colours represent different charge states.
- 10 tiers=100%
- Green = Sufficient battery
- Yellow = 30% battery remaining
- Red = undervoltage needs to be recharged.
It is recommended that when using an AGM battery, the yellow indicator light is on and you can use the smart charger configured by our company to charge it.
Installation of Squeegee Assembly
Due to the relationship of packaging, the suction squeegee is supplied separately, and the suction squeegee Y should be fixed on the suction squeegee bracket assembly Q as shown in the above figure, until the cable is loosened, and the suction pipe T is connected to the suction port P.
Squeegee Assembly height adjustment
- The height of the squeegee should be adjusted according to the rubber of the squeegee, and the specific adjustment methods are as follows:
- Rotate the adjusting nut J counterclockwise to raise the absorbent squeegee, and rotate the adjusting nut J clockwise to reduce the suction squeegee.
- The adjustment nuts on the left and right sides must be adjusted synchronously to ensure that the suction squeegee head remains parallel to the ground.
Sewage tanks
Turn over the sewage tank, check the connection between the suction pipe, the
sewage pipe and the sewage tank, see whether the parts are connected correctly
and sealed well, and further check whether the sewage suction pipe T and the
suction port P, the sewage pipe S and the sewage pipe plug F are connected
correctly and sealed well.
Clear water tank
Fill in clean water from the water tank filling port R.
Clean water
Add clean water with a cleaning solution temperature of no more than 50 °C to
the clean water tank, and the detergent put into the clean water tank is
recommended to be a neutral detergent with a pH value between 5-and 9, add the
least amount of detergent to avoid a large amount of foam damage to the
suction motor, and cover the lid of the clean water tank.
- Please use a low-foaming detergent, in the case of using detergent, a little defoamer must be added to the sewage tank, and the use of pure acid is prohibited!
Installation of the brush
- Before installing the brush disk, be sure to keep the power supply of the machine in the off position, that is, turn the key switch B to the 0 position;
- To avoid injury to the hands, all power supply of the machine should be cut off before the brush plate installation operation.
- After the base of the brush plate is lifted, insert the brush plate under the brush plate cover under the water tank until the three buckles on the brush plate are embedded in the card slot of the tray base, and rotate the brush plate to rotate the buckle to the direction of the card slot until the brush plate is completely fixed on the tray base. The image on the right shows the direction of rotation of the fixed brush disc.
Operation of the Machine
Second, the operation of the machine
Set up before work
- Connect the battery plug M;
- Set the master switch key B to the 1 position (clockwise), and the power indicator H will light up immediately.
- The water valve N manually adjusts the amount of clean water and selects the appropriate amount, which is enough to clean the floor and will not overflow from the outside of the baffle. In addition, please adjust it at any time according to the type of floor, the type of dust and the speed of travel;
- The machine head is tilted forward to lower the brush plate;
- Operate the control lever to reduce the water absorption head;
The march of the machine
Forward:
Press the brush switch and the water absorption switch, then hold the handle
with both hands to apply push force forward
- Even if you only retreat a short distance, lift the head of the slotting squeeze.
- The machine starts to move forward under this operation, the brush plate begins to rotate, and in the few meters when the machine starts to travel, check whether the water is sufficient, whether the suction squeegee can be completely dried, and whether the machine can continue to work until the clean water tank runs out.
- When a problem occurs during operation, please turn off all power supplies including the key switch of the main unit immediately, stop the work of the machine, and troubleshoot before restarting the machine.
Overflow device
When the water in the tank is full, the float in the tank is closed
- The suction pipe, to avoid damage to the suction motor, should be opened immediately, stop the machine from working and empty the sewage tank.
- This process must be operated with gloves to avoid contact with dangerous goods.
After the completion of the work, before any maintenance work, you should:
- The brush base is tilted behind the fuselage;
- Park the machine to a place where the sewage tank can be emptied;
- Turn the key switch B to the position of 0 (counterclockwise), that is, turn off the main power of the machine;
- Remove the sewage discharge pipe (S) from the dirty water tank.
- Remove the sewage discharge pipe plug F and empty the water tank.
- This should be done with gloves to avoid contact with dangerous objects.
- Remove the brush plate and clean it with the faucet (for the removal of the brush plate, see the section on removing the brush plate for details)
Daily maintenance
Clean the sewage tank
- Remove the sewage discharge pipe;
- Unplug and empty the dirty water tank;
- This process must be operated with gloves to avoid contact with dangerous goods.
- Clean the sewage tank with a water hose or spray gun, and discharge all the sewage;
- Keep the sewage tank clean to prevent it from being blocked by foreign objects;
- Reinstall all parts.
Clean the clean water tank filter
- Unplug the water filter G and clean it thoroughly;
- Reassemble all parts.
Clean the absorbent squeegee
To ensure the best drying results, check that the absorbent spatula is always
clean.
The clean absorbent spatula should:
- Remove the suction pipe T from the suction port P;
- Loosen the nut on the suction squeegee bracket assembly Q and remove the suction squeegee Y;
- Remove the suction pipe interface P and clean it;
- Clean the absorbent spatula thoroughly from the inside out;
- Clean the absorbent squeegee and rubber sheet thoroughly;
- Check whether the suction pipe on the suction squeegee is blocked regularly or when the suction equipment is not working properly.
- Reassemble all the parts again.
Remove the brush disk
- Lean back the fuselage to lift the brush disk base;
- Park the machine;
- Rotate the brush disc in the direction shown in the diagram, and then remove the brush disk;
- If it is not used for a long time, it is necessary to remove the brush plate clean it and dry it;
Clean the battery compartment
Wipe the battery box and battery with a dry rag regularly, keep it clean, and
check whether the connections of the battery power cord, including the binding
posts, are loose, please keep the connection tight and strong, otherwise it
will easily lead to overheating, affecting the normal charging and battery
life.
- This should be done with gloves to avoid contact with dangerous objects.
- Beware of evaporating gases and spilled corrosive media
- Indicate that there is a fire, stay away from the machine
Fourth, cycle maintenance
-
Replace the absorbent squeegee rubber
Check the wear and tear of the absorbent rubber sheet, if the wear is severe, please replace it according to the following procedures: -
Unplug the suction pipe T from the suction port P of the suction squeegee
-
Turn the nut on the squeak assembly;
-
Remove the squeegee from the bracket
-
Loosen the fixing screw (4) on the rubber fixing plate, and remove the fixing plate (5);
-
Replace the eraser (6). Reinstall the squeegee according to the above procedure.
Common faults and troubleshooting methods
Before entrusting the maintenance department or calling our customer service department, please check the following points:
Phenomenon
| Causes|
Solution
---|---|---
The brush motor is not working
| 1. Check that the power cord plug is plugged in correctly;
2. Check that the power socket is plugged in;
3. Check whether the corresponding working motor switch is turned on;
4. Check whether the working voltage of the machine is normal.
| 1. Plug in the power plug properly;
2. Properly check circuit fuses such as fuse measures to ensure that the socket has electricity
3. Turn on the switch of the corresponding working motor;
4. The machine should work at its required
working voltage.
No water or little water output| 1. The filter or fitting of the clean water tank is blocked;
2. If the floor is too dry, it generally means that the water volume cannot keep up with the first cleaning of the new building;
3. The solenoid valve or fitting is blocked.
| 1. Remove the filter or water outlet connector and clean the filter screen and fittings;
2. When the ground is too dry, additional water is needed on the ground;
3. Clean the solenoid valve and all joints.
Reduced water absorption| 1. Loose sealing strip of the sewage tank cover;
2. Loosening of the throat clamp; 3.Loose or skewed suction motor;
4. The suction pipe is not completely blocked;
5. The battery is low.
| 1. Connect the sealing strip well, and there should be no gap at the butt;
2. Check and lock the hose clamp;
3. Open the silencer cover, confirm that the motor is installed correctly and lock the screws;
4. Dredging the inlet and outlet air channels;
5. Charge.
The battery binding post is frozen, or the connecting wire
is heated
| 1. The connecting wire is not tightened and the contact is poor;
2. The connecting wire is tightened to the
binding post but there is a black metal gasket between them.
| 1. tighten the screws;
2. Remove the gasket and put the connecting wire terminal close to the battery binding post.
The water absorption is not clean
| 1. The suction pump does not rotate;
2. clogged suction pipe;
3. absorbent squeezes with foreign bodies;
4. Excessive wear and tear of the absorbent squeegee;
5. The height adjustment of the suction
squeegee is not suitable.
| 1. Check the motor (according to the reason why the motor does not rotate above); 2.Removal of foreign bodies;
3. Removal of foreign bodies;
4. Replace the front and rear scraper absorbent squeegee;
5. Adjust the height of the absorbent spatula.
The brush brush is not clean
| 1. The brush motor does not rotate;
2. The dirt is too stubborn; 3.Excessive wear of the brush disc;
4. Entanglement of foreign objects in the brush.
| 1. inspect the motor;
2. Targeted detergent is used and sprayed on the ground;
3. Replace the brush disk;
4. Clean up foreign objects.