ADA B0829XTT3T Digital Protractor Instruction Manual

June 28, 2024
ADA

ADA B0829XTT3T Digital Protractor

Product Features

  • Plastic alloy enclosure (lightweight and durable)
  • Relative/absolute measurement interchange at any position
  • With 2 built-in magnets on the measuring surface
  • Slope measurement in % and °
  • Power off automatically in 5 minutes
  • Portable size, convenient to co-work with other measuring tools

Technical Parameters

  1. Measuring range: 4×90°
  2. Resolution: 0.05°
  3. Accuracy: ±0.2°
  4. Battery: 9V
  5. Working temperature: 0°C ~40°C
  6. Dimension: 575730.5 mm
  7. With 2 built-in magnets, with a diameter of 10 mm on the measuring surface
  8. N. Weight: 0.13kg

Operating Instructions:

  1. Press the «ON/OFF» button, and it turns on, and the LCD has an absolute horizontal angle. «Level» is displayed on the screen. Press the «ON/OFF» button again to switch off the instrument.
  2. If you lift the left side of the instrument you will see the arrow «▲» on the left side of the display. On the right side of the display, you will see the arrow «▼». It means the left side is higher and right side is lower.
  3. Put the instrument on the horizontal stand, and press the «ZERO» button, the value returns to zero, and the read-out is the angle value measured relative to the horizontal stand. In this mode «Level» is not displayed.
  4. Press «Hold/Tilt%» to hold the value on the display. To continue angle measurement press the Hold/Tilt% button again.
  5. Press the «Hold/Tilt%» button for 2 seconds to measure the slope in %. To make angle measurement in degrees, press and hold the «Hold/Tilt%» button for 2 sec.
  6. The magnets at the bottom allow the instrument to be attached to an iron material measurement object. Press the «ZERO» button, and reset the value to proceed with relative measurement.

Application

Control and measurement of the slope of any surface. It is used in the wood processing industry (especially in the furniture manufacturing industry) for wood angle accurate cutting; auto repair industry for tiring assembling angle accurate controlling; in the machining industry for machine tool working angle accurate positioning; in woodwork; when setting guides for gypsum board partitions.

Calibration

  1. Press and hold the ZERO button to turn on the calibration mode. Then press and hold the ON/OFF button. Calibration mode is activated and “CAL 1” is displayed. Place the instrument on a flat and smooth surface as shown in the picture.
  2. Press the ZERO button once in 10 seconds. “CAL 2” will be displayed. Rotate the instrument by 90 degrees in a clockwise direction. Place it on the right edge towards the display.
  3. Press the ZERO button once in 10 seconds. “CAL 3” will be displayed. Rotate the instrument by 90 degrees in a clockwise direction. Place it on the upper edge towards the display.
  4. Press the ZERO button once in 10 seconds. “CAL 4” will be displayed. Rotate the instrument by 90 degrees in a clockwise direction. Place it on the left edge towards the display.
  5. Press the ZERO button once in 10 seconds. “CAL 5” will be displayed. Rotate the instrument by 90 degrees in a clockwise direction. Place it on the lower edge towards the display.
  6. Press the ZERO button once in 10 seconds. “PASS” will be displayed. After a while “0.00 degrees” will be also displayed. The calibration is over.

WARRANTY DOESN’T EXTEND TO FOLLOWING CASES

  1. If the standard or serial product number will be changed, erased, removed, or will be unreadable.
  2. Periodic maintenance, repair, or changing parts as a result of their normal runout.
  3. All adaptations and modifications with the purpose of improvement and expansion of the normal sphere of product application, mentioned in the service instruction, without the tentative written agreement of the expert provider.
  4. Service by anyone other than an authorized service center.
  5. Damage to products or parts caused by misuse, including, without limitation, misapplication or negligence of the terms of service instruction.
  6. Power supply units, chargers, accessories, and wearing parts.
  7. Products, damaged from mishandling, faulty adjustment, maintenance with low-quality and non-standard materials, presence of any liquids and foreign objects inside the product.
  8. Acts of God and/or actions of third persons.
  9. In case of unwarranted repair till the end of the warranty period because of damages during the operation of the product, its transportation, and storing, the warranty doesn’t resume.

WARRANTY CARD

The warranty period for the instrument exploitation is 24 months. During this warranty period, the owner of the product has the right to free repair of his instrument in case of manufacturing defects. Warranty is valid only with the original warranty card, fully and filled (stamp or mark of the seller is obligatory). Technical examination of instruments for fault identification which is under the warranty, is made only in the authorized service center. In no event shall the manufacturer be liable before the client for direct or consequential damages, loss of profit, or any other damage that occurs as a result of the instrument outage. The product is received in the state of operability, without any visible damages, in full completeness. It is tested in my presence. I have no complaints to the product quality. I am familiar with and agree with the conditions of warranty service.

Before operating you should read service instructions!
If you have any questions about the warranty service and technical support contact the seller of this product