Specifications:
- Product Name: SPEC-SELECTTM MINI WALL PACK
- Model Number: #39638
- Wattage Options: 15W, 20W, 25W
- Color Temperature Options: 3000K, 4000K, 5000K
Product Usage Instructions:
Installation:
Warning: Disconnect power before installing or
servicing the fixture.
Surface Mount:
-
Apply silicone sealant to mounting holes to prevent water
entry. -
Securely attach the fixture to the wall using the provided side
holes and 2 M4 screws. -
Follow the General Wiring Diagram for wire connections.
-
Adjust field settings as needed by following the instructions
provided.
Surface Mount with Junction Box:
-
Apply silicone sealant to mounting holes to prevent water
entry. -
Unscrew the front cover screws with a screwdriver.
-
Disconnect male and female connectors and remove the driver
box. -
Use the junction box as a template to drill holes for
mounting. -
Secure the fixture to the junction box and reconnect the
connectors. -
Reattach the front cover and adjust field settings as
needed.
Frequently Asked Questions (FAQ):
Q: Can I install this product without the help of an
electrician?
A: It is recommended to use a qualified electrician for
installation to ensure safety and proper setup of the
luminaire.
Q: What should I do for non-dimming applications regarding the
purple and pink wires?
A: For non-dimming applications, cap the purple and pink wires
separately to avoid malfunctioning and warranty void.
Q: Can I change the wattage and color temperature settings of
the fixture?
A: Yes, you can adjust the wattage and color temperature
settings by accessing the dip switches behind the clear cover on
the side of the fixture. Follow the provided instructions for
guidance.
“`
SPEC-SELECTTM MINI WALL PACK – #39638
INSTALLATION INSTRUCTIONS
PLEASE USE A QUALIFIED ELECTRICIAN FOR INSTALLATION. Read the instructions
before installing or use of the luminaire.
WARNING, CAUTIONS AND OPERATING INSTRUCTIONS · To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels. · Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. · Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician. · For the installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed electrician and check your local electrical code. · To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. · Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. WARNING: RISK OF FIRE OR ELECTRICAL SHOCK · Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply. · Turn off the power when you perform any maintenance. · Verify that supply voltage is correct by comparing it with the luminaire label information. · Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code requirements. · All wiring connections should be capped with UL approved wire connectors. CAUTION: RISK OF INJURY · Risk of burn. Disconnect power and allow fixture to cool before handling fixture. · Avoid direct eye exposure to the light source while it is on. · Luminaire is designed to operate in ambient temperatures ranging from -40°F to 122°F (-40°C to 50°C) · Minimum 75° supply conductors. · Suitable for Wet locations.
GENERAL INFORMATION
WARNING DISCONNECT POWER ! BEFORE INSTALLING OR SERVICING.
GENERAL WIRING DIAGRAM
Line Neutral Ground (+)DIM V+ ()DIM V-
Black White Ground Purple Pink
LED FIXTURE
*Note: For non-dimming applications, cap the purple and pink wires separately. Failure to do so may cause malfunctioning and void warranty.
FIELD ADJUSTABLE SETTINGS Fig. A 1. To change settings, remove
the clear cover on the side of the fixture (Fig. A). 2. Choose your settings
by moving the dip switch to the appropriate positions. (Fig. B) 3. Replace
clear cover.
Clear Cover
Selection Dip Switches located behind
the cover.
Fig. B
ON 1 2345
Wattage Selection Dip Switches 1 & 2
ON ON ON
Photo Cell Dip Switch 3
ON ON
CCT Selection Dip Switches 4 & 5
ON ON ON
12 12 12 25W 20W 15W
33 ON OFF
45 45 45 5000K 4000K 3000K
Specifications subject to change without notice. Photos and line drawings may not be to scale and are for general reference only.
SPEC-SELECTTM MINI WALL PACK – #39638
INSTALLATION INSTRUCTIONS
INSTALLATION
SURFACE MOUNT – Apply silicone sealant (not provided) to any mounting holes to
prevent water entry.
WARNING DISCONNECT POWER ! BEFORE INSTALLING OR SERVICING.
1. Attach the fixture securely to the wall using the side holes and 2 M4 screws.
2. Wire connections should follow the instructions in the General Wiring Diagram on page 1.
3. Adjust the field settings as needed, consulting page 1 for guidance.
SURFACE MOUNT WITH JUNCTION BOX – Apply silicone sealant (not provided) to any mounting holes to prevent water entry.
1. With a screwdriver, unscrew the front cover screws.
2. Disconnect the male and female connectors, then remove the driver box.
3. Use the junction box as a template to drill holes for mounting in the desired position. Secure the fixture to the junction box.
4. Reconnect the male and female ends and reattach the front cover.
5. Adjust the field settings as needed, consulting page 1 for guidance
Specifications subject to change without notice. Photos and line drawings may not be to scale and are for general reference only.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>