ICON PROCESS CONTROL TVF Series TVF Flow Display and Batcher User Manual
- June 27, 2024
- ICON PROCESS CONTROL
Table of Contents
- Symbol Explanation
- Basic Requirements | User Safety
- Specifications
- Front Panel Description
- Function of Push Buttons
- Dimensions
- Wiring Diagram
- Power Supply & Relay Connection
- Suppression Circuit Connection
- Flow Meter Connections (Relay Type)
- Programming K Factor
- Programming Relays
- Programming Batching
- Resetting Batch
- Resetting Totalizer
- Setting Decimal Point
- Warranty, Returns and Limitations
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LevelPro®— TVF Series
Flow Display | Controller | Batcher
Corrosion-Free
Instrumentation Equipment
Quick Start Manual
Read the user’s manual carefully before starting to use the unit.
Producer reserves the right to implement changes without prior notice.
Symbol Explanation
This symbol denotes especially important guidelines concerning the installation and operation of the device. Not complying with the guidelines denoted by this symbol may cause an accident, damage or equipment destruction.
Basic Requirements | User Safety
- Do not use the unit in areas threatened with excessive shocks, vibrations, dust, humidity, corrosive gasses and oils.
- Do not use the unit in areas where there is risk of explosions.
- Do not use the unit in areas with significant temperature variations, exposure to condensation or ice.
- The manufacturer is not responsible for any damages caused by inappropriate installation, not maintaining the proper environmental conditions and using the unit contrary to its assignment.
- If in the case of a unit malfunction there is a risk of a serious threat to the safety of people or property additional, independent systems and solutions to prevent such a threat must be used.
- The unit uses dangerous voltage that can cause a lethal accident. The unit must be switched off and disconnected from the power supply prior to starting installation of troubleshooting (in the case of malfunction).
- Do not attempt to disassemble, repair or modify the unit yourself. The unit has no user serviceable parts.
- Defective units must be disconnected and submitted for repairs at an authorized service center.
Specifications
General
Display| LED | 6 Digit | 13mm High | Red | Adjustable Brightness
Displayed Values| 0 ~ 999999
RS485 Transmission| 1200…115200 bit/s, 8N1 / 8N2
Housing Material| ABS | Polycarbonate
Protection Class| NEMA 4X | IP67
Input Signal | Supply
Standard| Current: 4-20mA | 0-20mA | 0-5V | 0-10V
Voltage| 85 – 260V AC/DC | 16 – 35V AC, 19 – 50V DC
Output Signal | Supply
Standard| 2 x Relays (5A) | 1 x Relay (5A) + 4-20mA
Communication| RS485
Voltage| 24VDC
Passive current output | 4-20mA | (Operating Range Max. 2.8 – 24mA)
Performance
Accuracy| 0.1% @ 25°C One Digit
Temperatures
Operating Temperature| -40 – 158°F | -40 – 70°C
Front Panel Description
Function of Push Buttons
| Symbol used in the manual: [ESC/MENU]
Functions:
• Enter to main menu ( press and hold for at least 3 sec.)
• Exit the current Screen and Enter to previous menu (or measure mode)
• Cancel the changes made in parameter being edited
---|---
| Symbol used in the manual : [ENTER/PAUSE]
Functions:
• Start to edit the parameter
• Enter into the sub-menu
• Confirmation of changes made in parameter being edited
• While batcher mode : Pause / Start Batching
| Symbol used in the manual : [ ∑ /RESET]
Functions:
• Switching of the display between total and instantaneous measurements or
batcher counter (while batcher mode only)
• Zeroing the currently displayed counter (Press & Hold for at least 2 Sec),
the zeroing must be confirmed by [ENTER] button
| Symbol used in the manual : [∧] [∨]
Functions:
• Change of the present menu
• Modification of the parameter value
• Switching of the display between relay thresholds and number of batches
counter.
Dimensions
Wiring Diagram
Due to possible significant interference in industrial installations,
appropriate measures assuring correct operation of the unit must be applied.
The unit is not equipped with an internal fuse or power supply circuit
breaker.
For this reason, an external time-delay cut-out fuse with a small nominal
current value must be used (recommended bipolar, max. 2A) and a power supply
circuit breaker located near the unit.
Power Supply & Relay Connection
Depending on Version
85/230/260V AC/DC ; 50 – 60 Hz
19/24 – 50V DC ; 16/24/35V AC
Contacts of relay outputs are not equipped with spark suppressors. When using the relay outputs for switching of inductive loads (coils, contactors, power relays, electromagnets, motors etc.) it is required to use additional suppression circuit (typically capacitor 47nF/ min. 250VAC in series with 100R/5W resistor), connected in parallel to relay terminals or (better) directly on the load.
Suppression Circuit Connection
Figure: Examples of Suppression Circuit Connection
a) To Stepper Relay Terminals b) To the Inductive Load (Motor)
OC-Type Output Connection
Figure: Examples of OC-type output connection
Current Output Connection Using Internal Power Supply
Figure: Example of current output connection using internal power supply
Current Output Connection Using External Power Supply
Figure: Example of current output connection using external power supply
Flow Meter Connections (Relay Type)
TKM Series : 4-20mA Output
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
11| Yellow| mA+
12| Grey| mA-
TKS Series : Pulse Output
GPM/Pulse = K factor
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
10| Black| NPN Pulse
Jump 13 G 8
TKW Series : Pulse Output
GPM/Pulse = K factor
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
10| Black| Pulse
Jump 13 G 8
TKW Series : 4-20mA Output
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
11| Black| mA+
12| White| mA-
TKP Series : Pulse Output
GPM/Pulse = K factor
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
10| Black| Pulse
Jump 13 G 8
TIW Series : Pulse Output
GPM/Pulse = K factor
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
10| White| Pulse
Jump 13 G 8
TIM | TIP Series : Pulse Output
GPM/Pulse = K factor
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
10| Black| Pulse
Jump 13 G 8
TIM Series : 4-20mA Output
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
11| Yellow| mA+
12| Grey| mA-
UF 1000 | 4000 | 5000 – Pulse Output
GPM/Pulse = K factor
TVF Terminal| Pin| Description
8| 1| +VDC
10| 2| Pulse
7| 3| -VDC
Jump 13 G 8
UF 1000 | 4000 | 5000 – 4-20mA Output
TVF Terminal| Pin| Description
8| 1| +VDC
11| 2| +mA
7| 3| -VDC
Jump 12 G 7
ProPulse (Flying Lead) – Pulse Output
GPM/Pulse = K factor
TVF Terminal| Wire Color| Description
7| Shield| -VDC
8| Red| +VDC
10| Blue| Pulse
Jump 13 G 8
ProPulse ® 2 – Pulse Output
TVF Terminal| Wire Color| Description
7| Blue| -VDC
8| Brown| +VDC
10| Black| Pulse
Jump 13 G 8
Programming K Factor
Programming Relays
Programming Batching
Programming Output (For 4-20mA Output Models)
Resetting Batch
Resetting Totalizer
Setting Decimal Point
- To change decimal points for Batch | Totalizer, select Batch | Totalizer Menu
Warranty, Returns and Limitations
Warranty
Icon Process Controls Ltd warrants to the original purchaser of its
products that such products will be free from defects in material and
workmanship under normal use and service in accordance with instructions
furnished by Icon Process Controls Ltd for a period of one year from the date
of sale of such products. Icon Process Controls Ltd obligation under this
warranty is solely and exclusively limited to the repair or replacement, at
Icon Process Controls Ltd option, of the products or components, which Icon
rocess Controls Ltd examination determines to its satisfaction to be defective
in material or workmanship within the warranty period. Icon Process Controls
Ltd must be notified pursuant to the instructions below of any claim under
this warranty within thirty (30) days of any claimed lack of conformity of the
product. Any product repaired under this warranty will be warranted only for
the remainder of the original warranty period. Any product provided as a
replacement under this warranty will be warranted for the one year from the
date of replacement.
Returns
Products cannot be returned to Icon Process Controls Ltd without prior
authorization. To return a product that is thought to be defective, go to
www.iconprocon.com, and submit a customer return (MRA) request form and follow
the instructions therein. All warranty and non-warranty product returns to
Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process
Controls Ltd will not be responsible for any products lost or damaged in
shipment.
Limitations
This warranty does not apply to products which: 1) are beyond the warranty
period or are products for which the original purchaser does not follow the
warranty procedures outlined above; 2) have been subjected to electrical,
mechanical or chemical damage due to improper, accidental or negligent use; 3)
have been modified or altered; 4) anyone other than service personnel
authorized by Icon Process Controls Ltd have attempted to repair; 5) have been
involved in accidents or natural disasters; or 6) are damaged during return
shipment to Icon Process Controls Ltd reserves the right to unilaterally waive
this warranty and dispose of any product returned to Icon Process Controls Ltd
where: 1) there is evidence of a potentially hazardous material present with
the product; or 2) the product has remained unclaimed at Icon Process Controls
Ltd for more than 30 days after Icon Process Controls Ltd has dutifully
requested disposition. This warranty contains the sole express warranty made
by Icon Process Controls Ltd in connection with its products. ALL IMPLIED
WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies
of repair or replacement as stated above are the exclusive remedies for the
breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE
FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR
REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE
FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS
AUTHORIZED TO MAKE ANY OTHER
WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This
warranty will be interpreted pursuant to
the laws of the province of Ontario, Canada.
If any portion of this warranty is held to be invalid or unenforceable for any
reason, such finding will not invalidate any other provision of this warranty.
For additional product documentation and technical support visit:
www.iconprocon.com | e-mail:
sales@iconprocon.com or
support@iconprocon.com | Ph: 905.469.9283
Corrosion-Free
Instrumentation Equipment
24-0293
© Icon Process Controls Ltd.