GWUYU JZ22-1 Wall Mounted AC Charging Pile Instruction Manual

June 25, 2024
GWUYU

GWUYU JZ22-1 Wall Mounted AC Charging Pile

GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-PRODUCT

Statement

  1. The document is only used for the household AC Charging station series products developed and produced by Icapia. and it includes important instructions that must be followed.
  2. The document provides details and operating instructions for users. Before using the product, please read the document carefully, and strictly follow the safety instructions. Please keep the manual well.
  3. The manual will be updated, adjusted, and corrected based on actual product upgrades. Users are advised to refer to the actual product purchased.
  4. In the actual use, malfunctions or doubts arise that cannot be learned through this manual. In the event of a resolution, please contact us promptly and do not operate on your own.
  5. All information in this document is subject to copyright and other intellectual property rights to Bolatu. The unauthorized use of any trademark displayed in this document is strictly prohibited.

Safety information

Warnings

  • Do not attempt to disassemble, repair, tamper with, or refit the Wall Connector. Please contact us for any repairs or modifications.
  • Do not install or use the Wall Connector near flammable, explosive, hash, or combustible materials, chemicals, or vapours.
  • Do not touch the Wall Connector’s end terminals with fingers or sharp metallic objects, such as wire, tools, or needles.
  • Keep the charging gun head clean and dry. If there is any dirt, please use a clean dry cloth to wipe it.

Cautions

  • In case of thunderstorm weather, please charge with caution.
  • Children are not allowed to approach or use the Wall Connector during charging.
  • In case of an emergency during product operation, the emergency button can be immediately pressed to cut off all input and output power supplies.

Prohibit

  • During the charging process, the vehicle is prohibited from driving and can only be charged when stationary.
  • Please turn off the vehicle before charging.
  • In case of the following situations, it is forbidden to use the Charging station, and the manufacturer should be contacted immediately:
  • The shell of the Wall Connector is damaged.
  • The connector or charging cable has defects, cracks, wear, and tear, and the charging cable is exposed.
  • Lightning strikes the Charging station.
  • Accident or fire near Charging station.

Overview

  • This product is used for AC slow charging of electric vehicles, with a highly simplified design and is divided into 7KW-9.6KW-12KW. Provide card swiping and plug charging methods, with multiple safety protection functions.
  • The equipment adopts the principle of industrial design, the overall protection level of the machine reaches IPSS, with good dustproof and waterproof functions, and can be safely operated and maintained outdoors.GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1 \(1\)
    1. RFID
    2. LED
    3. EMERGENCY STOP

FEATURE

Specifications Model 7kW-1P-32A 9.6kW-1P-40A 12kW-1P-48A
  Product name Single-phase wall-mounted AC charging pile
Appearance structure product type Easy home version
Shell material PC material body
Equipment size 325220100mm
Installation method Wall-mounted
Wiring mode Lower left power line in, lower right gun line out
Hardware configuration Gun length Sm
Emergency stop function Possess
Charging mode RFID card/Plug-and-play
Leakage protection TypeA
Communication method Wi-Fi (starter/optional)
Electrical index Input voltage 110V-240V
Input frequency 50Hz/60Hz
Maximum power 12kW (MAX)
Output voltage 110V-240V
Output current 48A (MAX)
Standby power <3W
Environmental indicators Applicable

scenario

| Indoor/Outdoor
Working temperature| -30°C—— +SS°C
Working humidity| 5% – 95% without condensation
Working altitude| <2000m
Protection grade| IPSS
Cooling mode| Natural cooling
MTBF| 100000 hours
Special protection| UV protection design
Safety design| Overvoltage protection, undervoltage protection, overload protection, leakage protection, grounding protection, over-temperature protection, lightning protection

Standard

The Single-phase AC Charging station is designed according to the latest national standards, and its function and performance meet the industry standards. The technical standards used are shown in the table below.

Serial Number Standard number Standard Name
1 SAE J1772(American standards) Compliant Electric Vehicle Service Equipment

Reference Design for Level1 and 2 EV Charger
2| NACS TS-0023666| North American Charging Standard For Tesla

Operation

Preparation

  1. Ensure that there are no flames around the equipment and that the surrounding space is not blocked.
  2. Ensure the integrity of the equipment casing and charging cable.
  3. Protection during the preparation period.

Ready

  1. After the Charging station is powered on, the interface displays the “Ready” status, as shown in the following figure: GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1 \(2\)
  2. The indicator LED on the casing is always green, as shown in the following figure:GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1 \(3\)

Tap the card

  1. After parks the electric vehicle at the station, please ensure that it is in the correct position.
  2. When the charging gun detects that the charging input is correct, the interface displays “Tap the Card” status, as shown in the following figure:GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1 \(4\)
  3. The indicator LED on the machine flashes, as shown in the following figure:

Charging

  1. Use an RFID card or Tuya Smart APP (optional) to authorize the charging
  2. The device starts charging, and the interface displays the “Charging” status and information parameters, as shown in the following figure:GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1 \(6\)
  3. The indicator LED on the casing is a blue breathing light

Waiting / Charging Stop

  1. In the charging state, the RFID card can be used to stop charging. When fully charged, the charging will automatically stop.
  2. Use an RFID card to authorize you to stop using the Charging station.
  3. After charging is completed, the end interface has two display effects:GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1 \(8\)

When the vehicle is fully charged, it will automatically stop charging or the user has set a delayed charging time, and the device is waiting to start charging. The display effect is shown in the above figure.

GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1 \(9\)

In the charging state, by manually swiping the card to stop charging, the device stops charging. The display effect is shown in the above figure.

WIFI Connection(optional)

  1. Please download the “Tuya Smart” APP on your mobile phone, with the icon shown in the following figure:
  2. After downloading, open the app, select Add Device, and follow the instructions to complete the addition of the new device, as shown in the following figure:GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1 \(11\)
  3. WIFI corner description (equipment must have WIFI function)GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1 \(12\)

INSTALLATION

GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1
\(13\) GWUYU-JZ22-1-Wall-Mounted-AC-
Charging-Pile-FIG-1 \(14\) GWUYU-JZ22-1-Wall-
Mounted-AC-Charging-Pile-FIG-1 \(15\)

TROUBLESHOOTING

GWUYU-JZ22-1-Wall-Mounted-AC-Charging-Pile-FIG-1
\(16\) GWUYU-JZ22-1-Wall-Mounted-AC-
Charging-Pile-FIG-1 \(17\)

LED WORD

Serial number charging Green blue Red Definition description
1 Ready On Off Off Power-on self-test or reset
2 Waiting flash Off Off The voltage of detection point 1 is 9 ± 0.8V,
3 Charging Off Breathing Off Detection point 1 voltage is 6 ± 0.8V, the

relay is closed
4| Chargin’ stop| Off| On| Off| Manually stop charging
5| Err: CP| Off| Off| Flash 1 time| The voltage of detection point 1 is 9.8V<U<ll.2V; 6.8V<U<8.2V; 12.8V<U or U<5.2V; the relay is off
6| Under Voltage| Off| Off| Flash 2 times| (single phase)Voltage<85V
7| Over Voltage| Off| Off| Flash 3 times| (single phase)Voltage>264V
8| Elec Leakage| Off| Off| Flash 4 times| The relay is disconnected, and it needs to be re-powered after the fault is removed before the relay is allowed to close
9| Over Current| Off| Off| Flash 5 times| When the line current is le+2< 1::e le+4,55, the relay is disconnected, and it will automatically restart after 105. Repeat three times for permanent disconnection. When I> le+4, the relay is disconnected, and the charging ends
10| Over Temp| Off| Off| Flash 6 times| Temperature>85 degrees, disconnect the relay, wait for the temperature <65 degrees, then turn on charging
11| Err: Reset| Off| Off| Flash 7 times| When the emergency stop button is pressed, the relay is disconnected. After the fault is removed, the relay is allowed to close(OR do not detect ID card)

FCC

FCC WARNING
This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used per the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user’s authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirements. To maintain compliance with FCC’s RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body, and fully supported by the operating and installation configurations of the transmitter and its antenna(s)

www.gwuyu.com.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals