GWUYU JZ22-1 Wall Mounted AC Charging Pile Instruction Manual
- June 25, 2024
- GWUYU
Table of Contents
GWUYU JZ22-1 Wall Mounted AC Charging Pile
Statement
- The document is only used for the household AC Charging station series products developed and produced by Icapia. and it includes important instructions that must be followed.
- The document provides details and operating instructions for users. Before using the product, please read the document carefully, and strictly follow the safety instructions. Please keep the manual well.
- The manual will be updated, adjusted, and corrected based on actual product upgrades. Users are advised to refer to the actual product purchased.
- In the actual use, malfunctions or doubts arise that cannot be learned through this manual. In the event of a resolution, please contact us promptly and do not operate on your own.
- All information in this document is subject to copyright and other intellectual property rights to Bolatu. The unauthorized use of any trademark displayed in this document is strictly prohibited.
Safety information
Warnings
- Do not attempt to disassemble, repair, tamper with, or refit the Wall Connector. Please contact us for any repairs or modifications.
- Do not install or use the Wall Connector near flammable, explosive, hash, or combustible materials, chemicals, or vapours.
- Do not touch the Wall Connector’s end terminals with fingers or sharp metallic objects, such as wire, tools, or needles.
- Keep the charging gun head clean and dry. If there is any dirt, please use a clean dry cloth to wipe it.
Cautions
- In case of thunderstorm weather, please charge with caution.
- Children are not allowed to approach or use the Wall Connector during charging.
- In case of an emergency during product operation, the emergency button can be immediately pressed to cut off all input and output power supplies.
Prohibit
- During the charging process, the vehicle is prohibited from driving and can only be charged when stationary.
- Please turn off the vehicle before charging.
- In case of the following situations, it is forbidden to use the Charging station, and the manufacturer should be contacted immediately:
- The shell of the Wall Connector is damaged.
- The connector or charging cable has defects, cracks, wear, and tear, and the charging cable is exposed.
- Lightning strikes the Charging station.
- Accident or fire near Charging station.
Overview
- This product is used for AC slow charging of electric vehicles, with a highly simplified design and is divided into 7KW-9.6KW-12KW. Provide card swiping and plug charging methods, with multiple safety protection functions.
- The equipment adopts the principle of industrial design, the overall protection level of the machine reaches IPSS, with good dustproof and waterproof functions, and can be safely operated and maintained outdoors.
- RFID
- LED
- EMERGENCY STOP
FEATURE
Specifications | Model | 7kW-1P-32A | 9.6kW-1P-40A | 12kW-1P-48A |
---|---|---|---|---|
Product name | Single-phase wall-mounted AC charging pile | |||
Appearance structure | product type | Easy home version | ||
Shell material | PC material body | |||
Equipment size | 325220100mm | |||
Installation method | Wall-mounted | |||
Wiring mode | Lower left power line in, lower right gun line out | |||
Hardware configuration | Gun length | Sm | ||
Emergency stop function | Possess | |||
Charging mode | RFID card/Plug-and-play | |||
Leakage protection | TypeA | |||
Communication method | Wi-Fi (starter/optional) | |||
Electrical index | Input voltage | 110V-240V | ||
Input frequency | 50Hz/60Hz | |||
Maximum power | 12kW (MAX) | |||
Output voltage | 110V-240V | |||
Output current | 48A (MAX) | |||
Standby power | <3W | |||
Environmental indicators | Applicable |
scenario
| Indoor/Outdoor
Working temperature| -30°C—— +SS°C
Working humidity| 5% – 95% without condensation
Working altitude| <2000m
Protection grade| IPSS
Cooling mode| Natural cooling
MTBF| 100000 hours
Special protection| UV protection design
Safety design| Overvoltage protection, undervoltage protection, overload
protection, leakage protection, grounding protection, over-temperature
protection, lightning protection
Standard
The Single-phase AC Charging station is designed according to the latest national standards, and its function and performance meet the industry standards. The technical standards used are shown in the table below.
Serial Number | Standard number | Standard Name |
---|---|---|
1 | SAE J1772(American standards) | Compliant Electric Vehicle Service Equipment |
Reference Design for Level1 and 2 EV Charger
2| NACS TS-0023666| North American Charging Standard For Tesla
Operation
Preparation
- Ensure that there are no flames around the equipment and that the surrounding space is not blocked.
- Ensure the integrity of the equipment casing and charging cable.
- Protection during the preparation period.
Ready
- After the Charging station is powered on, the interface displays the “Ready” status, as shown in the following figure:
- The indicator LED on the casing is always green, as shown in the following figure:
Tap the card
- After parks the electric vehicle at the station, please ensure that it is in the correct position.
- When the charging gun detects that the charging input is correct, the interface displays “Tap the Card” status, as shown in the following figure:
- The indicator LED on the machine flashes, as shown in the following figure:
Charging
- Use an RFID card or Tuya Smart APP (optional) to authorize the charging
- The device starts charging, and the interface displays the “Charging” status and information parameters, as shown in the following figure:
- The indicator LED on the casing is a blue breathing light
Waiting / Charging Stop
- In the charging state, the RFID card can be used to stop charging. When fully charged, the charging will automatically stop.
- Use an RFID card to authorize you to stop using the Charging station.
- After charging is completed, the end interface has two display effects:
When the vehicle is fully charged, it will automatically stop charging or the user has set a delayed charging time, and the device is waiting to start charging. The display effect is shown in the above figure.
In the charging state, by manually swiping the card to stop charging, the device stops charging. The display effect is shown in the above figure.
WIFI Connection(optional)
- Please download the “Tuya Smart” APP on your mobile phone, with the icon shown in the following figure:
- After downloading, open the app, select Add Device, and follow the instructions to complete the addition of the new device, as shown in the following figure:
- WIFI corner description (equipment must have WIFI function)
INSTALLATION
TROUBLESHOOTING
LED WORD
Serial number | charging | Green | blue | Red | Definition description |
---|---|---|---|---|---|
1 | Ready | On | Off | Off | Power-on self-test or reset |
2 | Waiting | flash | Off | Off | The voltage of detection point 1 is 9 ± 0.8V, |
3 | Charging | Off | Breathing | Off | Detection point 1 voltage is 6 ± 0.8V, the |
relay is closed
4| Chargin’ stop| Off| On| Off| Manually stop charging
5| Err: CP| Off| Off| Flash 1 time| The voltage of detection point 1 is
9.8V<U<ll.2V; 6.8V<U<8.2V; 12.8V<U or U<5.2V; the relay is off
6| Under Voltage| Off| Off| Flash 2 times| (single phase)Voltage<85V
7| Over Voltage| Off| Off| Flash 3 times| (single phase)Voltage>264V
8| Elec Leakage| Off| Off| Flash 4 times| The relay is disconnected, and it
needs to be re-powered after the fault is removed before the relay is allowed
to close
9| Over Current| Off| Off| Flash 5 times| When the line current is le+2< 1::e
le+4,55, the relay is disconnected, and it will automatically restart after
105. Repeat three times for permanent disconnection. When I> le+4, the relay
is disconnected, and the charging ends
10| Over Temp| Off| Off| Flash 6 times| Temperature>85 degrees, disconnect the
relay, wait for the temperature <65 degrees, then turn on charging
11| Err: Reset| Off| Off| Flash 7 times| When the emergency stop button
is pressed, the relay is disconnected. After the fault is removed, the
relay is allowed to close(OR do not detect ID card)
FCC
FCC WARNING
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used per the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Note: The Grantee is not responsible for any changes or modifications not
expressly approved by the party responsible for compliance. such modifications
could void the user’s authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirements. To
maintain compliance with FCC’s RF exposure guidelines, the distance must be at
least 20 cm between the radiator and your body, and fully supported by the
operating and installation configurations of the transmitter and its
antenna(s)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>