SUNCO LIGHTING LS-RWPO2B-40H 40W LED Wall Pack Light Fixture Instruction Manual

June 25, 2024
Sunco Lighting

SUNCO LIGHTING LS-RWPO2B-40H 40W LED Wall Pack Light Fixture

Product Information

  • Specifications:
    • Model No: LS-RWPO2B-40H 1JYT1SA1-BR50
    • PFC: 0.9
    • Wattage Tunable: 40W
    • Voltage/Current Input:
    • 120V – 0.33A
    • 277V – 0.14A
    • Light Efficiency: 135LM/W
    • Kelvin Options: 5000K

Product Usage Instructions

  • Installation & Mounting:
    • Installation Instruction:
    • This luminaire must be installed by a qualified electrician to avoid electric shock and fire accidents.
    • Wear gloves before installation to avoid injury.
    • Turn off the power immediately in case of smoke or fire during installation; inform professionals for inspection.
    • The luminaire is suitable for outdoor use.
  • Installation Steps:
    • Installation I:
    • Cut holes on the wall according to the locating plate.
    • Fix rubber plugs into the holes.
    • Align the mounting bracket with the hole and tighten the screws.
    • Make wiring connections and ensure isolation treatment.
    • Fix the luminaire on the bracket and tighten the screws on the bottom.
    • After installation, ensure all screws are tightened.
    • Installation II:
    • Cut holes on the wall according to the locating plate.
    • Fix rubber plugs into the holes.
    • Align the mounting bracket with the hole and tighten the screws.
    • Fix the luminaire on the bracket, make wiring connections from the side, and ensure isolation treatment.
    • Tighten the pipe on the luminaire, then tighten all screws after installation.

FAQs

  • Q: What should I do if I encounter issues during installation?
    • A: If you encounter any issues during installation, immediately turn off the power and contact a professional for assistance.

FEATURES

  • Rotatable optics design, can either up or down light
  • Great architecture design, aluminium alloy housing
  • Optics swivel 350 degrees in each direction
  • IP65 waterproof
  • 50,000 hours lifetime

SUITABLE APPLICATIONS

  • Warehouses
  • Stadiums
  • Factories
  • Parking Lots
  • Shopping Malls
  • Supermarkets
  • Logistic Centers
  • Auto dealerships

CONSTRUCTION:

  • Aluminum alloy housing with bronze powder-coated finish

OPTICAL SYSTEM:

  • High brightness luminleds 2835 chips
  • High Transmission PC optics
  • 60° beam angle

WARRANTY

  • 5-year limited warranty. Actual performance may differ as a result of end-user environment and application.

ELECTRICAL:

  • Available as 120-277V input
  • -4°F to 113°F

INSTALLATION & MOUNTING:

  • Wall mounting with backside plate for easy install

CONTROLS & DIMMING:

  • 0-10V dimmable

PERFORMANCE:

Model No| PFC| Wattage Tunable| Voltage/Current Input| Light Efficiency| Kelvin Options
---|---|---|---|---|---
120V| 277V
LS-RWPO2B-40H 1JYT1SA1-BR50| >0.9| 40W| 0.33A| 0.14A| 135LM/W| 5000K

Electric Characteristic

Specification/Model LDS-WPB-40W-120V-50K-V2
LED Driver UL driver
Input Power 40W
Lumens Output 5400LM
Efficiency 135LM/W
CRI >72
Colour Temperature 5000K
Input Voltage 120-277VAC
Light Distribution Type 60D
Working Temperature -4 ~ +113°F
Junction Temperature <167°F
Lamps Efficiency ≥90%
Certificate UL CUL DLC
Equivalent 120-200W MH/HPS

Dimension

Distribution Diagram

Note

  1. The installation and maintenance must be completed by electricians or professionals.
  2. Please cut off the power before installation and maintenance.
  3. The thermally insulating material is not allowed to cover the fixture.
  4. Please keep away from the corrosive substance.

Installation Instruction

Warning:

  1. Can not use the electric generator to test the LED lamp.
  2. This luminaire must be installed following your local electrical codes and requirements.
  3. Do not install the luminaire in the rain, to avoid lightning stroke and damage to the luminaire.

Installation Notice:

  1. This luminaire must be installed by a qualified electrician to avoid electric shock and fire accidents;
  2. Wear gloves before installation to avoid injury;
  3. Turn off the power immediately when there is smoke and fire during installation; inform professionals to overhaul;
  4. This luminaire is suited for outdoor use.
    • The installation of the product can be used when it is marked with “√ “.

Installation I: Wiring from the bottom of luminaire

  1. Cut holes in the wall according to locating the plate. (Figure 1-1)
  2. Fix rubber plugs into holes. (Figure 1-2)
  3. Align mounting bracket with hole; tightens crews. (Figure 1-3)
  4. Make a wiring connection and go through isolation treatment. ( Figure 1-4)
  5. Fix the luminaire on the bracket and tighten the screws on the bottom. (Figure 1-5)
  6. After installation, tighten the screws. (Figure 1-6)

Installation II: Wiring from the bottom of luminaire

  1. Cut holes in the wall according to locating the plate. (Figure 2-1)
  2. Fix rubber plugs into holes. (Figure 2-2)
  3. Align mounting bracket with hole; tighten screws. (Figure 2-3)
  4. Fix the luminaire on the bracket; make a wiring connection from the side and go through isolation treatment. (Figure 2-4)
  5. Tighten the pipe on the luminaire; after installation, tighten the screws. (Figure 2-5)

Installation II: Bracket installation

  1. Cut holes in the wall according to locating the plate. (Figure 3-1)
  2. Fix rubber plugs into holes. (Figure 3-2)
  3. Align mounting bracket with hole; tighten screws. (Figure 3-3)
  4. Pass wires through rubber ring and junction box, align with holes and lock junction box. (Figure 3-4)
  5. Make a wiring connection and go through isolation treatment. (Figure 3-5)
  6. Push the wires into the junction box; after installation, tighten the screws. (Figure 3-6)

Read User Manual Online (PDF format)