liftmaster security plus 2.0 manual: Premium Series Garage Door Opener User’s Guide
- June 16, 2024
- LifeMaster
Table of Contents
The LiftMaster PREMIUM Series Garage Door Opener User’s Guide is an essential resource for anyone who has purchased this top-of-the-line garage door opener. This guide contains important safety instructions that must be followed to ensure safe operation of the garage door opener. The LiftMaster PREMIUM Series Garage Door Opener is ONLY compatible with MyQ™ and Security✚ 2.0™ accessories, and periodic checks of the garage door opener are required to ensure safe operation. It is important to note that the door WILL NOT CLOSE unless the Protector System® is connected and properly aligned. This guide also includes detailed information on the features of the garage door opener, including Alert2Close, Timer-to-Close, MyQ™ technology, and Security✚ 2.0™ remote controls and door controls. The guide also provides instructions on how to use the garage door opener with a wall-mounted door control, remote control, wireless keyless entry, or MyQ™ accessory. With this comprehensive guide, users can rest assured that they have all the information they need to safely and effectively use their LiftMaster PREMIUM Series Garage Door Opener.
**
LiftMaster PREMIUM Series Garage Door Opener User’s
Guide
**
LiftMaster PREMIUM Series Garage Door Opener User’s Guide
-
Please read this guide and the enclosed safety materials carefully!
-
The door WILL NOT CLOSE unless the Protector System® is connected and properly aligned.
-
Periodic checks of the garage door opener are required to ensure safe operation.
-
This garage door opener is ONLY compatible with MyQ™ and Security✚ 2.0™ accessories.
-
DO NOT enable the Timer-to-Close feature if you are installing the garage
door opener on a one-piece door. The Timer-to-Close is to be used ONLY with sectional doors. -
Attach enclosed warning labels to the location indicated on label.
Important Safety Instructions
Safety Symbol and Signal Word Review
This garage door opener has been designed and tested to offer safe service
provided it is installed, operated, maintained and tested in strict accordance
with the instructions and warnings contained in this manual.
When you see these Safety Symbols and Signal Words on the following pages,
they will alert you to the possibility of serious injury or death if you do
not comply with the warnings that accompany them.
The hazard may come from something mechanical or from electric shock. Read the
warnings carefully.
**Warning
Mechanical
Warning**
Electrical
When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your garage door and/or the garage door opener if you do not comply with the cautionary statements that accompany it. Read them carefully.
IMPORTANT INSTALLATION INSTRUCTIONS
**WARNING**
To reduce the risk of SEVERE INJURY or DEATH:
-
READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.
-
Install garage door opener ONLY on properly balanced and lubricated garage door. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
-
ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener.
-
Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement.
-
Install garage door opener 7 feet (2.13 m) or more above fl oor.
-
Mount the emergency release within reach, but at least 6 feet (1.83 m) above the fl oor and avoiding contact with vehicles to avoid accidental release.
-
NEVER connect garage door opener to power source until instructed to do so.
-
NEVER wear watches, rings or loose clothing while installing or servicing opener. They could be caught in garage door or opener mechanisms.
-
Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height of 5 feet (1.5 m).
• away from ALL moving parts of the door. -
Place entrapment warning label on wall next to garage door control.
-
Place manual release/safety reverse test label in plain view on inside of garage door.
-
Upon completion of installation, test safety reversal system.
Door MUST reverse on contact with a 1-1/2″ (3.8 cm) high object (or a 2×4 laid fl at) on the fl oor. -
To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric and battery power BEFORE performing ANY service or maintenance.
-
DO NOT enable the Timer-to-Close functionality if operating either one-piece or swinging garage doors. To be enabled ONLY when operating a sectional door.
-
SAVE THESE INSTRUCTIONS.
Operation
Your garage door opener is equipped with features to provide you with greater
control over your garage door operation. Accessories provided with your garage
door opener will vary depending on the garage door opener model purchased.
ALERT2CLOSE
The Alert2Close feature provides a visual and an audible alert that an
unattended door is closing.
TIMER-TO-CLOSE (TTC)
The Timer-to-Close feature automatically closes the door after a specifi ed
time period that can be adjusted using a TTC enabled door control (Models
881LM or 880LM). Prior to and during the door closing the garage door opener
lights will fl ash and the garage door opener will beep.
MyQ™
MyQ™ technology uses a 900MHz signal to provide two-way communication between
the garage door opener and MyQ™ enabled accessories. Your garage door opener
is compatible with up to 16 MyQ™ accessories.
REMOTE CONTROLS AND DOOR CONTROLS (SECURITY✚2.0™)
Your garage door opener has already been programmed at the factory to operate
with your remote control, which changes with each use, randomly accessing over
100 billion new codes. Compatible with MyQ™ and Security✚ 2.0™.
NOTE: Older LiftMaster remote controls, door controls, and third party
products are not compatible.
Accessories (Security✚ 2.0™): MEMORY CAPACITY
Remote Controls: Up to 24
Door Controls: Up to 2 Smart Control Panels or 4 of any other Security+
2.0™ door controls
Keyless Entries: Up to 2
THE PROTECTOR SYSTEM® (SAFETY REVERSING SENSORS)
When properly connected and aligned, the safety reversing sensors will detect
an obstruction
in the path of the infrared beam. If an obstruction breaks the infrared beam
while the door is
closing, the door will stop and reverse to full open position, and the opener
lights will fl ash
10 times. If the door is fully open, and the safety reversing sensors are not
installed, or are
misaligned, the door will not close from a remote control. However, you can
close the door
if you hold the button on the door control or keyless entry until the door is
fully closed. The
safety reversing sensors do not affect the opening cycle.
ENERGY CONSERVATION
For energy effi ciency the garage door opener will enter sleep mode when the
door is fully closed. The sleep mode shuts the garage door opener down until
activated. The sleep mode is sequenced with the garage door opener light bulb;
as the light bulb turns off the sensor LEDs will turn off and whenever the
garage door opener lights turn on the sensor LEDs will light.
LIGHTS
The garage door opener light bulbs will turn on when the opener is initially
plugged in; power is restored after interruption, or when the garage door
opener is activated. The lights will turn off automatically after 4-1/2
minutes. An incandescent A19 light bulb (100 watt maximum) or for maximum
energy effi ciency a 26W (100W equivalent) compact fl uorescent light (CFL)
bulb may be used.
Light Feature
The garage door opener is equipped with an added feature; the lights will turn
on when someone enters through the open garage door and the safety reversing
sensor infrared beam is broken. For added control over the light bulbs on your
garage door opener.
USING YOUR GARAGE DOOR OPENER
The garage door opener can be activated through a wall-mounted door control,
remote control, wireless keyless entry or MyQ™ accessory. When the door is
closed and the garage door opener is activated the door will open. If the door
senses an obstruction or is interrupted while opening the door will stop. When
the door is in any position other than closed and the garage door opener is
activated the door will close. If the garage door opener senses an obstruction
while closing, the door will reverse. If the obstruction interrupts the sensor
beam the garage door opener lights will blink 10 times. However, you can close
the door if you hold the button on the door control or keyless entry until the
door is fully closed.
The safety reversing sensors do not affect the opening cycle. The safety
reversing sensor must be connected and aligned correctly before the garage
door opener will move in the down direction.
Using the Door Control
PUSH BAR
Press the push bar to open and close the door.
LIGHT BUTTON
Press the LIGHT button to turn the garage door opener lights on or off. When
the lights are turned on they will stay on until the LIGHT button is pressed
again, or until the garage door opener is activated. Once the garage door
opener is activated the lights will turn off after the specified period of
time (the factory setting is 4-1/2 minutes). The LIGHT button will not control
the lights when the door is in motion. The duration of the light timing can be
adjusted using the door control.
Push Bar
Light Button
MOTION-DETECTING CONTROL PANEL The following features are accessible by
lifting the push bar:
LEARN A DEVICE
Any compatible remote controls, wireless keyless entry, or MyQ™ accessories
can be programmed to the garage door opener by pressing the Learn button on
the Motion-Detecting Control Panel.
LOCK
The LOCK feature is designed to prevent activation of the garage door opener
from remote controls while still allowing activation from the door control and
keyless entry. This feature is useful for added peace of mind when the home is
empty (i.e. vacation).
AUTOMATIC LIGHT
Motion Sensor
Factory default is set to on. This feature automatically turns on the garage
door opener lights when motion is sensed. The lights will come on for the set
period of time, then shut off. If using the garage door opener light as a work
light disable the motion sensor, otherwise the light will turn off
automatically if you are beyond the range of the sensor.
Light Feature
The lights will turn on when someone enters through the open garage door and
the safety reversing sensor infrared beam is broken.
MAINTENANCE ALERT SYSTEM (MAS)
This feature assists the homeowner in ensuring the garage door opener system
stays in good working condition. When the garage door opener needs to be
serviced (approximately 4500 garage door opener cycles) the command (yellow)
and service (red) LEDs will begin to alternately fl ash back and forth. The
factory setting for the MAS feature is off and can be activated at time of
installation. Contact your installing dealer for service.
Programming – Motion-Detecting Control Panel
Features:
Lock:
NOTE: Your remote controls will NOT work when LOCK mode is active however
your keyless entry will still allow access to your garage. Activate: Press and
hold the LOCK button for 2 seconds. The command LED will flash as long as the
lock feature is activated and your handheld remote control will not operate
your door at this time. Deactivate: Press and hold the LOCK button gain for 2
seconds. The command LED will stop flashing and normal operation will resume.
Light:
To change the amount of time the garage door opener lights will stay
on:
Press and hold the LOCK button until the garage door opener lights fl ash.
The time interval is indicated by the number of fl ashes.
NUMBER OF TIMES GARAGE DOOR OPENER LIGHTS FLASH 1:2:3:4
TIME THE GARAGE DOOR OPENER LIGHT STAYS ON 1 ½ Minutes: 2 ½ Minutes: 3 ½
Minutes: 4 ½ Minutes
To cycle through the time intervals repeat the step above.
Deactivate: Press and hold the LIGHT button until the garage door opener
lights turn on, then off again.
Activate: Start with the garage door opener lights on. Press and hold the
LIGHT button until the garage door opener lights turn off, then on again.*
-
Approximately 10 seconds
Motion Sensor: Activate/Deactivate: Slide the motion sensor switch ON or OFF.
To Program a Remote Control or Keyless Entry:- Press the LEARN button on the door control to enter Programming Mode.
- Press the LEARN button again, the LED will fl ash once.
- Remote Control: Press the button on the remote control that you wish to operate your garage door.
Keyless Entry: Enter a 4-digit personal identifi cation number (PIN) of your
choice on the keyless entry keypad. Then press the ENTER button.
The garage door opener lights will fl ash (or two clicks will be heard) when
the code has been programmed. If programming is unsuccessful, repeat steps 1-3
or program the remote using the learn button on the garage door opener.
Maintenance Alert System (MAS):
Activate/Deactivate
Press and hold the LEARN button. Then press the LIGHT button. The service LED
will fl ash the status; Active is 2 fl ashes and deactivated is 3 fl ashes.
Programming – Remote Controls
Your garage door opener has been programmed at the factory to operate with your remote control. Older LiftMaster remote controls are NOT compatible. Programming can be done through the door control or the Learn button on the garage door opener. To program additional remote controls refer to the instructions provided with the additional remote controls or visit www.liftmaster.com. If your vehicle is equipped with a Homelink®, you may require an external adapter depending on the make, model, and year of your vehicle. Visit www.homelink.com for additional information.
PROGRAM A REMOTE USING THE LEARN BUTTON ON THE GARAGE DOOR OPENER
-
Press and release the Learn button on the garage door opener. The Learn indicator light will glow steadily for 30 seconds.
-
Within 30 seconds, press and hold the button on the remote control.
-
Release the button when the garage door opener light blinks.
It has learned the code. If light bulbs are not installed, two clicks will be heard.
When replacing the light lens cover, ensure the antenna wires are hanging straight down.
ERASE ALL REMOTE CONTROLS AND KEYLESS ENTRIES
- Press and hold the learn button on garage door opener until the learn LED goes out (approximately 6 seconds). All remote control and keyless entry codes are now erased. Reprogram any accessory you wish to use.
ERASE ALL DEVICES (Including MyQ™ enabled accessories)
- Press and hold the learn button on garage door opener until the learn LED goes out (approximately 6 seconds).
- Immediately press and hold the learn button again until the learn LED goes out. All codes are now erased. Reprogram any accessory you wish to use.
To Open the Door Manually
**WARNING**
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
- If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
- NEVER use emergency release handle unless garage doorway is clear of persons and obstructions.
- NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
DISCONNECT THE TROLLEY
- The door should be fully closed if possible.
- Pull down on the emergency release handle.
RECONNECT THE TROLLEY
The lockout feature prevents the trolley from reconnecting automatically.
- Pull the emergency release handle down and back (toward the opener). The door can then be raised and lowered manually as often as necessary.
- To disengage the lockout feature, pull the handle straight down.
The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote control.
Battery Backup (If applicable)
The battery backup system allows access in and out of your garage, even when
the power is out. When the garage door opener is operating on battery power,
the garage door opener will run slower, the light will not function, the
Battery Status LED will glow solid orange, and a beep will sound approximately
every 2 seconds.
The battery charges when the garage door opener is plugged into a 110Vac
electrical outlet that has power and requires 24 hours to fully charge. A
fully charged battery supplies 12Vdc to the garage door opener for one to two
days of normal operation during an electrical power outage. After the
electrical power has been restored, the battery will recharge within 24 hours.
The battery will last approximately 1 to 2 years with normal usage.
Instructions for replacement are provided with the battery. To obtain maximum
battery life and prevent damage, disconnect the battery when the garage door
opener is unplugged for an extended period of time.
NOTE: When the garage door opener is in battery backup mode the garage
door opener lights, Timer-to-Close, and Remote Close features are unavailable.
BATTERY STATUS LED
NOTE: The Battery Status LED is most visible with the garage door
opener light off.
Battery does not have to be fully charged to operate the garage door opener.
GREEN LED:
All systems are normal.
- A solid green LED light indicates the battery is fully charged.
- A fl ashing green LED indicates the battery is being charged.
ORANGE LED:
The garage door opener has lost power and is in battery backup mode.
- A solid orange LED with beep, sounding approximately every 2 seconds, indicates the garage door opener is operating on battery power.
- A fl ashing orange LED with beep, sounding every 30 seconds, indicates the battery is low.
RED LED:
The garage door opener’s 12V battery needs to be replaced.
- A solid red LED with beep, sounding every 30 seconds, indicates the garage door opener needs servicing. Please call for replacement battery to allow your system to operate during a power outage.
Adjustment
Introduction
WARNING:
Without a properly installed safety reversal system, persons (particularly
small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
- Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
- After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2″ (3.8 cm) high object (or 2×4 laid fl at) on floor.
CAUTION:
To prevent damage to vehicles, be sure fully open door provides adequate
clearance.
Your garage door opener is designed with electronic controls to make setup and
adjustments easy. The adjustments allow you to program where the door will
stop in the open (UP) and close (DOWN) position.
The electronic controls sense the amount of force required to open and close
the door.
NOTE: If anything interferes with the door’s upward travel it will stop.
If anything interferes with the door’s downward travel, it will reverse.
PROGRAMMING BUTTONS
The programming buttons are located on the left side panel of the garage door
opener and are used to program the travel.
1. Program the Travel
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
- Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
- After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2″ (3.8 cm) high object (or 2×4 laid flat) on floor.
1.1 Press and hold the Adjustment Button until the UP Button begins to fl ash and/or a beep is heard.
1.2 Press and hold the UP Button until the door is in the desired UP position.
NOTE: The UP and DOWN Buttons can be used to move the door up and down
as needed.
1.3 Once the door is in the desired UP position press and release the
Adjustment Button. The garage door opener lights will fl ash twice and the
DOWN Button will begin to flash.
1.4 Press and hold the DOWN Button until the door is in the desired DOWN
position.
NOTE: The UP and DOWN Buttons can be used to move the door up and down
as needed.
1.5 Once the door is in the desired DOWN position press and release the
Adjustment Button. The garage door opener lights will flash twice and the UP
Button will begin to flash.
1.6 Press and release the UP Button. When the door travels to the
programmed UP position, the DOWN Button will begin to fl ash.
1.7 Press and release the DOWN Button. The door will travel to the programmed DOWN position. Programming is complete.
***** If the garage door opener lights are flashing 5 times during the steps for Program the Travel, the programming has timed out. If the garage door opener lights are fl ashing 10 times during the steps for Program the Travel, the safety reversing sensors are misaligned or obstructed. When the sensors are aligned and unobstructed, cycle the door through a complete up and down cycle using the remote control or the UP and DOWN buttons. Programming is complete. If you are unable to operate the door up and down, repeat the steps for Programming the Travel.
2. Test the Safety Reversal System
WARNING
Without a properly installed safety reversal system, persons (particularly
small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
• Safety reversal system MUST be tested every month.
• After ANY adjustments are made, the safety reversal system MUST be tested.
Door MUST reverse on contact with 1-1/2″ high (3.8 cm) object (or 2×4 laid fl
at) on the floor.
2.1 With the door fully open, place a 1-1/2 inch (3.8 cm) board (or a 2×4
laid fl at) on the fl oor, centered under the garage door.
2.2 Press the remote control push button to close the door. The door MUST
reverse when it makes contact with the board.
If the door stops and does not reverse on the obstruction, increase the down
travel (refer to Adjustment Step 1).
Repeat the test. When the door reverses upon contact with the 1-1/2 inch
board, remove the board and open/close the door 3 or 4 times to test the
adjustment.
If the test continues to fail, call a trained door systems technician.
3. Test the Protector System ®
WARNING
Without a properly installed safety reversing sensor, persons (particularly
small children) could be SERIOUSLY INJURED or KILLED by a closing garage door.
3.1 Open the door. Place the garage door opener carton in the path of the
door.
3.2 Press the remote control push button to close the door. The door will
not move more than an inch (2.5 cm), and the garage door opener lights will
flash 10 times.
The garage door opener will not close from a remote control if the LED in
either safety reversing sensor is off (alerting you to the fact that the
sensor is misaligned or obstructed).
If the garage door opener closes the door when the safety reversing sensor is
obstructed (and the sensors are no more than 6 inches [15 cm] above the fl
oor), call for a trained door systems technician.
Maintenance
EVERY MONTH
- Manually operate door. If it is unbalanced or binding, call a trained door systems technician.
- Check to be sure door opens and closes fully. Adjust if necessary.
- Test the safety reversal system. Adjust if necessary.
EVERY YEAR
- Oil door rollers, bearings and hinges. The garage door opener does not require additional lubrication. Do not grease the door tracks.
- (If applicable) Test the battery backup and consider replacing the battery to ensure the garage door opener will operate during an electrical power outage.
Testing the Battery Backup:
-
Unplug the garage door opener. The battery status LED will either glow solid orange indicating opener is operating on battery power or will fl ash indicating low battery power.
-
Open and close the door using the remote control or door control.
NOTE: The garage door opener may run slower if the battery is not fully charged. The battery will take 24 hours to fully charge. -
Plug in the garage door opener. Verify the battery status LED is fl ashing green, indicating the battery is charging.
EVERY TWO TO THREE YEARS
- Use a rag to wipe away the existing grease from the garage door opener rail. Reapply a small layer of white lithium grease to the top and underside of the rail surface where the trolley slides.
The Remote Control Battery
WARNING:
To prevent possible SERIOUS INJURY or DEATH:
- NEVER allow small children near batteries.
- If battery is swallowed, immediately notify doctor.
To reduce risk of fi re, explosion or chemical burn:
- Replace ONLY with 3V2032 coin batteries.
- DO NOT recharge, disassemble, heat above 212°F (100°C) or incinerate.
The lithium batteries should produce power for up to 5 years. If the battery
is low, the remote control’s LED will not flash when the button is pressed. To
replace battery, pry open the case fi rst in the middle (1), then at each side
(2 and 3) with the visor clip. Insert battery positive side up.
Replace the batteries with only 3V2032 coin cell batteries. Dispose of old
batteries properly.
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment
or modifications of this transceiver are prohibited. THERE ARE NO USER
SERVICEABLE PARTS. Any changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment.
This device complies with Part 15 of the FCC rules and IC RSS-210. Operation
is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
Troubleshooting
Diagnostic Chart
Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage door opener will fl ash the diagnostic codes.
DIAGNOSTIC CODE:
SYMPTOM:
SOLUTION
Up arrow Flash(es); Down arrow Flash(es)
1; 1: The garage door opener will not close and the light bulbs flash.:
Safety sensors are not installed, connected, or wires may be cut. Inspect
sensor wires for a disconnected or cut wire.
1; 2:
The garage door opener will not close and the light bulbs flash.
There is a short or reversed wire for the safety sensors. Inspect safety
sensor wire at all staple and connection points, replace wire or correct
as needed.
1; 3:
The door control will not function.:
The wires for the door control are shorted or the door control is faulty.
Inspect door control wires at all staple and connection points, replace wire
or correct as needed.
1; 4:
The garage door opener will not close and the light bulbs flash.:
Safety sensors are misaligned or were momentarily obstructed. Realign both
sensors to ensure both LEDs are steady and not fl ickering. Make sure nothing
is hanging or mounted on the door that would interrupt the sensor’s path while
closing;.
1; 5:
Door moves 6-8″ stops or reverses.:
Manually open and close the door. Check for binding or obstructions, such
as a broken spring or door lock, correct as needed. Check wiring connections
at travel module and at the logic board. Replace travel module if necessary.
No movement, only a single click.:
Manually open and close the door. Check for binding or obstructions, such
as a broken spring or door lock, correct as needed. Replace logic board if
necessary.:
Opener hums for 1-2 seconds no movement.:
Manually open and close the door. Check for binding or obstructions, such
as a broken spring or door lock, correct as needed. Replace motor if
necessary.
1; 6:
Door coasts after it has come to a complete stop.:
Program travel to coasting position or have door balanced by a trained door
systems technician.
2; 1-5:
No movement, or sound.:
Replace logic board.
3; 2:
Unable to set the travel or retain position.
Check travel module for proper assembly, replace if necessary.
3; 3:
The battery status LED* is constantly fl ashing green.:
Battery backup* charging circuit error, replace the logic board.*
If applicable.
4; 1-4:
Door is moving stops or reverses.:
Manually open and close the door. Check for binding or obstructions, such
as a broken spring or door lock, correct as needed. If the door is binding or
sticking contact a trained door systems technician. If door is not binding or
sticking attempt to reprogram travel.
4; 5:
Opener runs approximately 6-8″, stops and reverses.:
Communication error to travel module. Check travel module connections, replace
travel module if necessary.
4; 6:
The garage door opener will not close and the light bulbs flash.:
Safety sensors are misaligned or were momentarily obstructed. Realign both
sensors to ensure both LEDs are steady and not fl ickering. Make sure nothing
is hanging or mounted on the door that would interrupt the sensor’s path while
closing.**
My garage door opener beeps:
The garage door opener can beep for several reasons:
- Garage door opener has been activated through a device or feature such as Timer-to-Close, garage door monitor or LiftMaster Internet Gateway.
- Operating on battery power or the 12Vdc battery needs to be replaced (if applicable).
My remote control will not activate the garage door:
- Verify the lock feature is not activated on the door control.
- Reprogram the remote control.
- If the remote control will still not activate the door check the diagnostic codes to ensure the garage door opener is working properly.
My door will not close and the light bulbs blink on my motor unit:
The safety reversing sensor must be connected and aligned correctly before the
garage door opener will move in the down direction.
- Verify the safety sensors are properly installed, aligned and free of any obstructions.
My garage door opener light(s) will not turn off when the door is open:
The garage door opener is equipped with a feature that turns the light on when
the safety reversing sensors have been obstructed or when the motion sensor on
the door control detects movement in the garage. These features can be
disabled using the door control.
My neighbor’s remote control opens my garage door:
Erase the memory from your garage door opener and reprogram the remote
control(s).
My vehicle’s Homelink® is not programming to my garage door opener:
Depending on the make, model, and year of your vehicle an external adapter may
be required. Visit www.homelink.com for
additional information.
Repair Parts
NOTE: For additional parts not shown, visit www.liftmaster.com to download or print the full owner’s manual.
DESCRIPTION: PART NUMBER
1 Light Lens: 41A7562
2 Receiver Logic Board – Model 8350 & 8360: 45DCT
Receiver Logic Board – Model 8355 & 8365: 45ACT
3A Travel Module – Model 8350 & 8360: 41A7114-7
3B Travel Module – Model 8355 & 8365: 41D7742-7
4A Motor w/Travel Module – Model 8350 & 8360: 41D1739-1
4B Motor w/Travel Module – Model 8355: 41D7442
4C Motor w/Travel Module – Model 8365: 41D7440
5 3V2032 Lithium Battery (Remote Control): 10A20
6 Backup Battery (if applicable): 485LM
7 Safety Sensor Kit with receiving and sending sensors with 3 feet (.9
m) 2-conductor wire: 41A5034
Warranty
LIFTMASTER® ONE YEAR LIMITED WARRANTY
LIFETIME MOTOR AND BELT LIMITED WARRANTY
ONE YEAR LIMITED WARRANTY FOR THE BATTERY BACKUP SYSTEM
The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser
of this product, for the residence in which this product is originally
installed, that it is free from defects in materials and/or workmanship for a
period of one year from the date of purchase, except that the motor and belt
are warranted to be free from defects in materials and/or workmanship for the
lifetime of the product while you own your residence, and the Battery Backup
System is warranted to be free from defects in materials and/or workmanship
for a period of one year from the date of purchase. The proper operation of
this product is dependent on your compliance with the instructions regarding
installation, operation, and maintenance and testing. Failure to comply
strictly with those instructions will void this limited warranty in its
entirety.
If, during the limited warranty period, this product appears to contain a
defect covered by this limited warranty, call
1-800-528-9131, toll free, before
dismantling this product. You will be advised of disassembly and shipping
instructions when you call. Then send the product or component, pre-paid and
insured, as directed to our service center for warranty repair. Please include
a brief description of the problem and a dated proof-of purchase receipt with
any product returned for warranty repair. Products returned to Seller for
warranty repair, which upon receipt by Seller are confirmed to be defective
and covered by this limited warranty, will be repaired or replaced (at
Seller’s sole option) at no cost to you and returned pre- paid. Defective
parts will be repaired or replaced with new or factory-rebuilt parts at
Seller’s sole option. [You are responsible for any costs incurred in removing
and/or reinstalling the product or any component.] ALL IMPLIED WARRANTIES
FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION
TO THE APPLICABLE LIMITED WARRANTY PERIOD SET FORTH ABOVE FOR THE RELATED
COMPONENT(S), AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD.
Some states do not allow limitations on how long an implied warranty lasts, so
the above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT
COVER NON DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR
CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE
REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS
TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT,
REPLACEMENT OF CONSUMABLE ITEMS (E.G., BATTERIES IN REMOTE CONTROL
TRANSMITTERS AND LIGHT BULBS), OR UNITS INSTALLED FOR NON RESIDENTIAL USE.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE
GARAGE DOOR OR GARAGE DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR
SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS LIMITED WARRANTY ALSO
DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. UNDER NO CIRCUMSTANCES
SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES
ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT
SHALL SELLER’S LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT,
NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY.
NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION
WITH THE SALE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of consequential,
incidental or special damages, so the above limitation or exclusion may not
apply to you. This limited warranty gives you specific legal rights, and you
may also have other rights, which vary from state to state.
LiftMaster 7675 User Manual Orignal-PDF
LiftMaster 7675 User Manual Optimize-PDF
SPECIFICATION
PRODUCT SPECIFICATION
|
Description
---|---
Compatibility
|
ONLY compatible with MyQ™ and Security✚ 2.0™ accessories
Required Safety Feature
|
The Protector System® must be connected and properly aligned for the door to close
Timer-to-Close Feature
|
Can only be enabled with sectional doors, not one-piece or swinging doors
Accessories Memory Capacity
|
Up to 24 remote controls, up to 2 door controls for Smart Control Panels or up to 4 of any other Security+ 2.0™ door controls, and up to 2 keyless entries
Energy Conservation
|
Garage door opener will enter sleep mode when the door is fully closed
Lights
|
Incandescent A19 light bulb (100 watt maximum) or 26W (100W equivalent) compact fluorescent light (CFL) bulb may be used
Using the Door Control
|
Can be activated through a wall-mounted door control, remote control, wireless keyless entry or MyQ™ accessory
Maintenance Alert System (MAS)
|
Service LED will flash the status; Active is 2 flashes and deactivated is 3 flashes
FAQS
Is this compatible with the 8165???
Yes
how do you open to replace batteries?
There is a slit on the side of the device that allows you to pop open the back with a screwdriver.
**Is this compat w/ Craftsman mfg 1996 1/2 hp 139.53535srt1 hope I remembered
right?**
The remote that will work with your opener will be the LiftMaster 893MAX. it’s compatible with all LiftMaster® garage door openers manufactured since 1993.
Is this compatible with chamberlain liftmaster professional 1/2 hp model 3255 (2013)?
No it’s for 2016 and news
Will this work for a Lifemaster 857 motor?
You mean Liftmaster,it says on my Garage opener Liftmaster P3 Motors Security +2.0 and in the back is the part number 41D7675 and works great.
Does his work with a “yellow button” receiver. We have a gate.
It work on my garage door which has a yellow light when you push the learn button.
Is this compatible with 8500?
Please note YES the Lift Master 891LM remote is compatible with the Lift Master 8500.
Does this model come with a built in light?
No, this model does not come with a light.
Can I install this myself?
This model is designed for DIY installation.
How much does the liftmaster garage door opener weigh?
The Liftmaster 8355 weighs about 40 pounds.
How far from the wall should I mount the garage door opener?
You should mount it at least 2 inches away from the wall.
What is the most dependable garage door opener?
BEST OVERALL: Genie StealthDrive Connect 7155 Garage Door Opener.
BEST BANG FOR THE BUCK: Genie Ultra-Quiet Belt Drive Garage Door Opener.
BEST SCREW-DRIVE: Genie Signature Series Screw Drive Garage Door Opener.
BEST WITH CAMERA: Chamberlain B4545T Smart Garage Door Opener.
Is LiftMaster a good garage door opener?
This LiftMaster model is our top choice for the best overall garage door opener in this review. You get a chain-drive system for affordability and reliability, with a 0.5-HP motor for fast opening and closing the garage door.
Can you replace a garage door opener?
There are several reasons you could find yourself needing overhead garage door opener replacement. Opener remotes typically last 10 to 15 years, so you should replace yours if it’s getting old or worn out.
How much horsepower do you need for a garage door?
Ratings ranging from 1/2 horsepower to 1-1/2 horsepower are typical for residential models. If you have a sectional double-car garage door, a 1/2-horsepower motor should be sufficient, but a higher-power model will operate with less effort and less wear and tear on the motor.
Should you grease garage door tracks?
It is important to lubricate all moving parts of your garage door every six months including the garage door track. Make sure you’re using an all- weather product, since low temperatures can cause lubricants to become thick and viscous. This makes it harder to open and close the door.
What kind of lubricant is best for garage door?
Silicone spray is the best option for lubricating garage door locks, since the thin spray nozzle is perfect for reaching into the locking mechanisms. A quick blast of lubricant in the key slot and the locking shafts should be enough. Wipe away any excess with a rag.
Does Lowe’s sell LiftMaster?
LiftMaster Wireless Rolling Code Garage Door Opener Keypad in the Garage Door Opener Keypads department at Lowes.com.
How hard is it to replace an existing garage door opener?
Installing a garage door opener is a moderately challenging task that can be accomplished in an afternoon using essential tools you probably already have in your home collection.
Can a garage door opener be too powerful?
Is it possible that your garage door opener’s power is too much and may not work properly? Yes! It might sound far-fetched, but if you choose a garage door opener with a higher horsepower than required, it can lift the garage door too high and can even break it! Especially if it’s lightweight.
How much does Lowes charge to install a garage door?
Installation of Garage Doors by Lowes ranges from $199 to $599 , and it depends on the size of the doors and its location. Installing a garage requires skill and time, and standard doors ranges from $600 to $1500. The labor costs are also added, and the new door costs around $300 to $1100.
Can the Timer-to-Close feature be enabled if the garage door opener is
installed on a one-piece door?
No, the Timer-to-Close feature is to be used ONLY with sectional doors.
What is the Protector System® and why is it important?
The Protector System® is a safety feature that detects obstructions in the path of the infrared beam. It is important because the door WILL NOT CLOSE unless the Protector System® is connected and properly aligned.
What accessories is the LiftMaster PREMIUM Series Garage Door Opener
compatible with?
The garage door opener is ONLY compatible with MyQ™ and Security✚ 2.0™ accessories.
What is the maximum number of remote controls that can be programmed with
the garage door opener?
Up to 24 remote controls can be programmed with the garage door opener.
How many MyQ™ accessories is the garage door opener compatible with?
Your garage door opener is compatible with up to 16 MyQ™ accessories.
What should be done before installing the garage door opener?
An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH. ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener. Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement.
How can the Maintenance Alert System (MAS) be activated or deactivated?
Press and hold the LEARN button. Then press the LIGHT button. The service LED will flash the status; Active is 2 flashes and deactivated is 3 flashes.
What should be done before using the garage door opener for the first time?
Upon completion of installation, test safety reversal system. Door MUST reverse on contact with a 1-1/2″ (3.8 cm) high object (or a 2×4 laid flat) on the floor.
How can the garage door opener be activated?
The garage door opener can be activated through a wall-mounted door control, remote control, wireless keyless entry or MyQ™ accessory.
How does the Energy Conservation feature work?
For energy efficiency, the garage door opener will enter sleep mode when the door is fully closed. The sleep mode shuts the garage door opener down until activated.