Lifemaster LMPAC8 Portable Air Conditioner User Manual
- June 15, 2024
- LifeMaster
Table of Contents
Lifemaster LMPAC8 Portable Air Conditioner
USER TIPS
Read all instructions carefully before setting up and operating the unit.
Please keep this instruction manual for future reference. This manual is
designed to provide you with important information needed to set up, operate,
maintain and troubleshoot your portable air conditioner. Failure to follow
these instructions may damage and/or impair operation and void the warranty.
USER TIPS
- Please avoid such operations, in case of any safety and health risks.
- Such instructions are to be followed. for safety and health concerns.
PRECAUTION
- For household use only.
- For indoor use only: please place the A/C in a dry environment.
- In case of a blocked air exchange, never stack any items around the machine.
- To avoid damage, never place any heavy items on the machine.
- Do not operate the machine with wet hands or in a humid environment.
- Please wipe the machine with a soft cloth, instead of wax, diluent or irritant detergent.
- Clean the filter once every two weeks.
- For your health, never drink condensed water discharged from the machine.
- Please unplug the power cord, if the machine will not be used for a long time.
- Non-professionals are not allowed to dismantle or repair the machine.
SAFETY WARNINGS
- A damaged power cord or plug shall not be used. Never plug to a loose socket.
- Never damage the power cord, or use an unlicensed power cord. Make sure the voltage is right.
- Do not modify or extend the power cord.
- A grounded outlet is suggested for the machine.
- In case of electric shock, never plug/unplug with wet hands.
- To unplug, pull the plug end instead of the wires.
- Never control the on/off status by directly plugging/unplugging.
- Please turn off the machine before unplugging.
- Never overload the socket
- Keep away from heat sources or direct sunlight exposure.
- If there is any acute noise. smell or smoke, turn off and unplug for diagnosis.
- In case of electric shock. never damage the power cord by placing heavy objects on it.
- Never insert fingers or any hard objects into the Louvre.
- Keep electrical parts away from water.
- If water enters, turn off and unplug in time; and call for check and repair from a professional.
- Please turn off and unplug before wiping, cleaning or replacing components.
- If gas leakage happens, open the window for ventilation before plugging the machine.
- The appliance can be used by children of or above 8 years old and persons with reduced physical, sensory or psychological capabilities if they have been given supervision and instruction concerning proper use and hazards of the appliance.
TIPS
- For a proper work of compressor. place the machine vertically on even ground.
- For proper ventilation. keep the machine at least 50cm from objects nearby.
- Never use the appliance near gasoline or other flammable objects.
- Keep the appliance from spraying agent or any solvent, or plastics may deform and electrical parts may even be damaged.
PRODUCT OVERVIEW
Main Components
- Handle
- Air Inlet Grille (Up)
- Control Panel
- Casters
- Louver
- Air Outlet Grille
- Drainage Hole
- Air Inlet Grille (Down)
- Air Exhaust Duct Assembly
- Window Sealing Kit
- Drain Hose
CONTROL PANEL AND REMOTE CONTROL
-
Power Button
Press the button for ON/OFF -
Fan Speed Button
Press the key to choose high/low speed. -
UP/Down Button for Temperature and Timer
Under cooling mode, press the keys could increase or decrease the setting temperature: In timer mode, press the keys could set the time to turn on. By pressing the keys together, a switch between °C and °F can be made. -
Temperature and Timer Display
The window will indicate temperature and time. -
Timer Button
- Press the key at standby mode would set ON time
- Press the key at ON mode would set OFF time
-
Mode Button
Press the key to choose cooling, fan, and dry. -
Temperature Switch Button
The button is to switch between °C and °F -
Sleep button
The button is to choose sleep mode.
OPERATION
Place & Installation
- Place
- Place the machine on the horizontal floor near the window.
- For proper ventilation and the best machine performance, keep the appliance at least: 50cm from objects nearby.
- Install
Air Exhaust Duct Assembly
STEP 1: Clip-fixture Type
- Measure window size;
- Adjust Length of the plate according to window size;
- Lock the plate
STEP 2: Fix the plate to the window.
STEP 3: Swirl the exhaust pipe assembly (exhaust fitting end) into the rear panel outlet (counterclockwise).
STEP 4: Insert the exhaust pipe assembly (exhaust port end) into the window seal panel assembly and screw it up.
Incorrect installation
- It’s important to keep the exhaust duct smooth. Incorrect installation will affect the work of the A/C.
- Prevent the exhaust duct from sharp bending.
- Ensure air can flow smoothly in the duct.
Warning
The exhaust duct is designed especially for this model. Don’t replace or
lengthen it; otherwise, it will fail.
NOTICE: The air exhaust duct can stretch up to 1500mm. To avoid bending, stretch it as short as possible
REMOTE CONTROL
Please install the battery correctly before using the remote control. The
specific steps are as follows:
- Slide to open the battery cover on the back;
- Insert 2* AAA (DCl .5V) new batteries and install electrodes correctly when inserted:
- Fit the batteries in place.
WARNINGS:
- Only AAA DC 1 .5V batteries are allowed, never use chargeable batteries or other types of batteries.
- Replace both batteries: never mix new battery with old one.
- Please remove batteries if the appliance is not to be used for a long time.
WARNINGS:
- Never use leaked batteries;
- Chemicals in batteries could result in such health hazards as burns. If the liquid in batteries splashes to skin or clothes, please wash with clean water in time. If batteries are swallowed, please rinse your mouth immediately with clean water and then go to the doctor.
HOW TO OPERATE
- Cooling Mode
- Under cooling mode, the cooling indicator will light on.
- Temperature Setting is from l 6°C to 30°C ( 60°F to 86°F).
- Press Fan Speed Button to choose from low/high fan speed
- Fan Mod
- Under Fan mode, the indicator will be on.
- Press Fan Speed Button to choose from low /high fan speed.
- Temperature cannot be set under this mode.
- Dry Mode
- Dry indicator will be on under this mode.
- Remove water plug (see right), and insert one end of pipe to the drainage hose, the other end would be in water tank or water channel.
- If ambient Temp. -, 7°C or 62°F compressor starts and follows the below sequence: if ambient Temp. 015°C or 59°F compressor stops; when it reaches 17°Cor 62°F, compressor starts again. (There would be a 3-min delay for compress or protection)
- Fan runs with a fixed low speed.
- Temp. is fixed.
Notes: Under dry mode, please dismantle air exhaust duct, or performance will be affected and the water full alarm “FL” will buzz.
TIMER MODE
- In standby mode, press Timer button to set ON time. A range of l to 24 Hours could be set with UP/DOWN button. Timer indicator will light up in this mode.
- Under the running state, press Timer button to set OFF time. A range of l to 24 Hours could be set with UP/DOWN button. Timer indicator will light up in this mode.
CLEAN AND MAINTENANCE
With a self-evaporating system, the appliance could perform better and save
energy in a way of cooling down the condenser by reusing condensed water.
The appliance would display “FL” with a buzz sound if the built-in water
container is full. After the compressor stops, please drain the water as
follows:
- Unplug and dismantle the air exhaust duct;
- Move the appliance to the right place;
- Pull out the water plug, and drain all water;
- Re-insert the water plug;
- Re-install the air exhaust duct, and restart the appliance.
MAINTENANCE
WARNING: In case of electric shock, turn off and unplug before repair or maintenance.
Body Clean
- Unplug before cleaning.
- Clean with a soft and half-wet cloth. In case of damage to the appearance or the appliance, never use chemical reagents, such as benzene, alcohol and gasoline.
- Never let splash water enter the appliance.
The filter is to be cleaned once every two weeks. If the air quality indoors is poor, it has to be washed more often, or the performance of the appliance will be lowered due to a blocked filter screen. Please follow the below instructions for cleaning: Take off the air inlet grille as indicated in the photo; pull out the filters. Cleon the filter in 40°C or l 04°F warm water or water with neutral detergent; dry the filter in a cooling area. Re-install the filter and grille after drying is completed; restart the appliance .
WARNING: Do not wash with a filter in water above 40°C (l 04°F) or with irritating detergents such as alcohol, gasoline and benzene. In case of deformation, filter ore is to be kept away from heat sources and dried naturally in a cooling area. Never operate the appliance when the filter is not installed.
Seasonal Maintenance
If the appliance will not be in use for a long time. please maintain by the
below steps:
- Pull out the water plug for drainage.
- Run in Fan mode for at least 2 hours to dry internal parts.
- Turn off and unplug.
- Clean the filter and reinstall.
- Dismantle the air exhaust duct and keep it well.
- Take off batteries.
- Wrap the appliance in a plastic bag and keep it in a dry and cooling place
If the appliance hasn’t been used for a long time, please pay attention to the following when to be used again:
- Make sure the water plug and filter are installed.
- Never use a damaged power cord; Check before use.
- Insert batteries.
- Assemble other parts according to the instructions.
COMMON FAILURES AND DIAGNOSIS
Intelligent Error Detection
Error-detecting code | Multi-functional defection |
---|---|
E1 | Error of the coil’s temperature sensor |
E2 | Error of indoor temperature sensor |
E4 | Anti-freezing protection: temperature of the coil is too low and the |
whole A/C is off. When temperature excesses 8°C (46.4°F), the protection is released and the previous working state is recovered.
TROUBLESHOOTING
The following table lists the common faults and maintenance methods of this
series of portable A/C. When the machine is in abnormal operation. the
following table can be used for simple diagnosis and maintenance. If it still
can’t be solved. please contact professional maintenance personnel.
TROUBLE | CAUSE | SOLUTION |
---|---|---|
The A/C doesn’t work | No display | Reset the circuit breaker on the AC cord |
The display panel displays “FL” | Restart the A/C after powering off and |
draining. then it will become normal
The time OFF function is started| The A/C can be restarted 3 minutes after
being turning off
The A/C starts frequently| Direct sunlight| Drow the curtain
Doors and windows are kept open; there are lots of people or heat sources in
the room| Close doors and windows.
remove heat source
The filter screen is very dirty| Cleon or replace it
The air inlet or air outlet is blocked| Remove the stem
Loud noise on the A/C| The A/C is placed unevenly| Place it at even and
ground. ovoid shaking
The compressor doesn’t work| Its delay protection started| Wait for 3min, turn
on after temperature decreases
Additional warning for appliances with R32 refrigerant gas (refer to the rating plate for the type of refrigerant gas used)
CAUTION ON FIRE
READ THE MAUAL CAREFULLY BEFORE USING THE APPLIANCE R32 refrigerant. This
appliance contains approximately 5.82 Oz refrigerant gas. The appliance shall
be installed, operated and stored in a room with a floor area larger than 4m2.