MFFIRE Nova Series Reduced Clearance Kit Owner’s Manual
- June 14, 2024
- MFFIRE
Table of Contents
MFFIRE Nova Series Reduced Clearance Kit
Product Information
Specifications
- Nova Series Reduced Clearance Kit (RCK)
- Manufacturer: MF Fire, Inc.
- Model Options:
- Nova Reduced Clearance Kit (MF02-RCK)
- Nova 2 Reduced Clearance Kit (MF03-RCK)
- Includes:
- Nova Series Pipe Shield (0364-000-C)
- Reduced Clearance Air Duct:
- Nova Reduced Clearance Air Duct (N92)
- Nova 2 Reduced Clearance Air Duct (N93)
Product Usage Instructions
Installation
- Refer to the respective product Owner’s Manual for installation instructions.
- Place the pipe shield atop the stove, centred behind the double wall connector pipe, set back by 1/2 off the back of the double wall pipe.
- No additional securement is needed for the pipe shield.
- The reduced clearance air duct should be hung from the two rear air duct bolts already installed on the rear of the stove.
Safety Precautions
- Always follow clearance to combustible requirements specified in the manual.
- Do not operate the stove if any parts of the Reduced Clearance Kit are damaged or removed.
- Consult local building or fire officials for installation restrictions and inspection requirements in your area.
FAQ
-
Q: What should I do if the pipe shield is damaged or removed?
A: If the pipe shield is damaged or removed, the stove cannot be operated unless clearance to combustibles is re-evaluated based on guidance in the respective product Owner’s Manual. -
Q: How should I install the reduced clearance air duct?
A: The reduced clearance air duct should be hung from the two rear air duct bolts already installed on the rear of the stove.
Safety Notice
Please save these instructions for future reference. Please check our website for the most up-to-date version of this manual. Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Do not install Nova Series™ in a mobile home!
The Nova Series Reduced Clearance Kit is installed to receive lower back wall clearance to combustibles. This Owner’s Manual is intended for use as a supplement to:
- Nova™ and Nova Tower Owner’s Manual
- Nova 2™ and Nova 2 Tower Owner’s Manual
- Nova Bench and Nova 2 Bench Owner’s Manual
OVERVIEW
If any portions of the Nova Series Reduced Clearance Kit are damaged or removed, the stove cannot be operated unless clearance to combustibles is re- evaluated based on guidance in the respective product Owner’s Manual. Failure to follow all clearance to combustible requirements may result in property damage, bodily injury, or even death.
| | Nova, Nova Tower, Nova Bench Double Wall Connector Pipe with
Reduced Clearance Kit| Nova 2, Nova 2 Tower, Nova
2 Bench Double Wall Connector Pipe with Reduced Clearance Kit
---|---|---|---
A| Sidewall to unit| 20” (508 mm)| 22” (559 mm)
B| Backwall to unit| 7.5” (191 mm)| 9” (229 mm)
C| Sidewall to connector| 28” (711 mm)| 31” (787 mm)
D| Backwall to connector| 11” (280 mm)| 12.5” (318 mm)
Your Reduced Clearance Kit is comprised of two parts, depending on your model:
Nova Reduced Clearance Kit (MF02-RCK) | Nova 2 Reduced Clearance Kit (MF03-RCK) |
---|---|
Nova Series Pipe Shield (0364-000-C) | Nova Series Pipe Shield (0364-000-C) |
Nova Reduced Clearance Air Duct (N92) | Nova 2 Reduced Clearance Air Duct (N93) |
USING
The pipe shield should be placed atop the stove, centred behind the double wall connector pipe. It must be set back by 1/2” off the back of the double wall pipe. No additional securement is needed. If the pipe shield is damaged or removed, the stove cannot be operated unless clearance to combustibles are re-evaluated based on guidance in the respective product Owner’s Manual. Failure to follow all clearance to combustible requirements may result in property damage, bodily injury, or even death.
The reduced clearance air duct should be hung from the two rear air duct bolts already installed on the rear of the stove.
Manufactured by:
MF Fire, Inc.
3031 Washington Blvd STE G
Baltimore, MD, USA
Confidential and Proprietary. 2023 Copyright © by MF Fire, Inc. All Rights
Reserved.