Tommee Tippee closer to nature Double Electric Breast Pump Instruction Manual
- June 8, 2024
- Tommee Tippee
Table of Contents
- PARTS GUIDE (See Image A)
- MOTOR FUNCTION (See Image D)
- DISASSEMBLING THE ELECTRIC BREAST PUMP
- CLEANING, STERILIZING, AND MAINTENANCE
- ASSEMBLING THE DOUBLE ELECTRIC BREAST PUMP
- USING THE DOUBLE ELECTRIC BREAST PUMP
- ELECTRO MAGNETIC COMPATIBILITY
- HELPFUL ADVICE
- TROUBLESHOOTING
- SING THE MILK PROTECTION PODS AND TRAY
- STORAGE OF BREAST MILK
- STERILIZING
- **STORAGE AND USE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
closer to nature®
Double electric breast pump
INSTRUCTIONS
Please read and retain this important information for future reference.
www.tommeetippee.com
*See pack for detailed explanations of system
closer to nature®
Double electric breast pump
*For hygiene reasons this product cannot be returned once opened unless faulty.
IMPORTANT SAFEGUARDS, SAVE THESE INSTRUCTIONS. FOR HOUSEHOLD USE ONLY.
The intended use of the Tommee Tippee Electric Breast Pump is to express milk from the breast of lactating women. Researched and developed by specialists and breastfeeding experts to express milk for storage and later use.
PARTS GUIDE (See Image A)
1. Silicone insert
2. Horn
3. Upper pump body
4. Lower pump body
5. Release tabs
6. Diaphragm
7. Diaphragm cap
8. Valve
9. Air tube
10. Single to double connector
11. Motor unit
12. 5 oz bottle
13. 9 oz bottle
14. Horn hygiene cover (combines as bottle stand for 5 oz bottle only)
15. Air tube socket
16. Electric adapter socket (from mains)
17. Milk storage lid
18. 2oz & 4oz milk storage pods and tray
19. Bottle bag (holds 4x 9oz bottles with milk storage lids)
20. Breast pads
21. Battery
22. Adapter
MOTOR FUNCTION (See Image D)
1a. Expressing time
1b. Expressing level
1c. Battery charge indicator (displayed when operating from batteries)
2. Slide open digital display panel to power on – level one
3. Slide close to power off (Automatic shut off after 45 minutes)
4. Slide open to restart
5. Level two touch pad
6. Level three touch pad
7. Level four touch pad
8. Level five touch pad
DISASSEMBLING THE ELECTRIC BREAST PUMP
1. Unscrew bottle from lower pump body.
2. Pull off valve.
3. Pull air tube from upper pump body and motor unit.
4. Press release tabs to release upper pump body and pull apart.
5. Pull out diaphragm cap and diaphragm.
6. Pull horn from lower pump body.
IT IS NOT ESSENTIAL TO TAKE THE SILICONE INSERT OUT OF THE HORN FOR CLEANING unless milk or dirt has become trapped inside. If so, unclip lip from horn and pull apart.
CLEANING, STERILIZING, AND MAINTENANCE
-
Before use ensure the breast pump has been disassembled, washed and sterilized.
The parts to be sterilized are silicone insert, horn, upper pump body, lower pump body, diaphragm, diaphragm cap, valve, bottle, horn hygiene cover, and milk storage lid or milk storage pods if required (as shown in image B). These components are suitable for sterilization by steam (electric and microwave), boiling, or cold water tablet/ liquid solution. Follow the sterilizer manufacturer’s instructions. -
Do not sterilize: single to double connector, air tube, motor unit, and adapter. Wipe clean only with a damp cloth (as shown in image C).
-
Always wash the product immediately after use to remove milk residue.
-
Wash all products to be sterilized in warm soapy water and rinse in clean water or use a dishwasher.
-
Do not clean with solvents or harsh chemicals.
-
Do not allow product to come into contact with oil-based foods (e.g. oil/tomato-based sauces) as staining will occur.
-
Inspect the air tube before and after each use for condensation. Allow to air dry before next use.
-
To clean the valve, rub gently between your fingers in warm soapy water – do not insert objects as damage could result.
-
Routine maintenance includes cleaning. No other servicing is required.
ASSEMBLING THE DOUBLE ELECTRIC BREAST PUMP
Wash your hands thoroughly before handling the pump.
Wash and sterilize your breast pump before using. Follow instructions in
section for CLEANING, STERILIZING AND MAINTENANCE.
-
Make sure the silicone inserts are securely attached to both horns. Clip lip over end of cup first, then push tube through funnel, ensuring lip is fully clipped over the other side also.
-
Push both horns onto the lower pump body as far as they will go.
-
Push diaphragm down into lower pump body as far as it will go and push diaphragm cap over the top as far as it will go until it is sealed.
-
Push upper pump body and lower pump body together. They will click into place.
-
Push valve onto lower pump body.
-
Screw bottle onto lower pump body.
-
Connect air tube onto upper pump body and the air tube socket of the motor unit. This is on the LEFT of the two sockets on the motor unit.
-
Plug the electric adapter into the electric adapter socket of the motor unit. This is on the RIGHT.
-
Plug the electric adapter into the mains power supply.
INSTALLING THE BATTERY FOR THE FIRST TIME
- Before first use, the battery must be charged for at least 3 hours.
- To install, remove screw, slide open the battery cover to remove.
- Insert the battery as indicated inside the battery compartment and push the cover back into place until it clicks shut.
- Secure with screw.
- Battery will recharge when plugged in at the mains and the digital display panel is closed.
Help the environment by disposing of your product responsibly. The product and
batteries must not be disposed of in the domestic waste as they contain
substances which can be damaging to the environment and health. Please use
designated collection points or recycling facilities
when disposing of the item or batteries.
CAUTION :
Don’t immerse in water.
Don’t discard or leave the battery near heat source. May explode if disposed
into fire.
Don’t connect the positive and negative terminal directly.
Don’t strike, throw or trample the battery.
Never disassemble the cell.
Battery pack Model: 455068P (2S1P) can only use on the double Breast Pump
For replacement Lithium Ion Polymer batteries 455068P (2SIP), contact www.tommeetippee.com, or use the recommended Mains Adapter (PSU) S01563C DEBP (522663) conforms to the requirements of IEC 60601-1-2 (EMC). Adapter (501513A) conforms to the requirement of UL 60601-1
USING THE DOUBLE ELECTRIC BREAST PUMP
-
Ensure that the breast pump parts that come into contact with the breast or milk have been cleaned and sterilized. Wash your hands before touching the breast pump or your breasts and avoid touching inside the breast pump or the milk protection pod. Find a comfortable chair where you can relax.
-
Ensure the connector switch is in the central position for double expressing.
-
BEFORE placing the breast pump on the breast, switch on to level 1 by sliding the digital display panel up on the motor. The time will commence on the digital display panel.
-
Place both horns over the breast.
-
Ensure the horn has a good seal to the breast. IF AIR CAN GET IN THERE WILL BELOW OR NO SUCTION.
-
Once your milk starts to flow freely after approximately one minute, we recommend you press the level 2 touchpad. The pad LED will light up green to show you are on level 2.
-
To increase the expression level, press level 3 touchpad. If expressing is uncomfortable at this level, switch back to the lower level by touching the level 2 touchpad.
-
If you would like to express faster than level 3, press level 4 or 5 touchpads until you find the expression level that suits you to achieve maximum comfort.
-
Do not fill higher than the maximum level indicated on the bottle.
-
To switch off slide the digital display panel down.
-
Once you have completely finished pumping, unplug the breast pump.
-
You do not need to sterilize your pump parts until you are ready to use it again, but it is recommended to clean immediately after use to remove milk residue.
-
Cover and store the expressed milk for later use.
USING THE DOUBLE ELECTRIC BREAST PUMP AS A SINGLE ELECTRIC BREAST PUMP
- To use the breast pump for single pumping, slide the connector switch to the left for expressing from the left breast, or to the right for expressing from the right breast.
- The second horn does not need to be connected for single pumping.
WARNING!
- The battery must be removed from the appliance before it is scrapped.
- The appliance must be disconnected from the supply mains when removing the battery.
- The battery is to be disposed of safely.
- If the supply cord is damaged, it must be replaced by the manufacturer, in order to avoid a hazard.
- Do not immerse motor unit, single to double connector, and air tube in water or clean with wet sponge or cloth.
- Keep all components out of reach of children.
- Children should be supervised to ensure that they do not play with the appliance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- The use of accessories, transducers, and cables other than those specified with the exception of transducers and cables sold by the manufacturer of the MODEL 1092 as replacement parts for internal components may result in increased EMISSIONS or decreased IMMUNITY of the MODEL 1092.
- MODEL 1092 should not be used adjacent to or stacked with other equipment.
ELECTRO MAGNETIC COMPATIBILITY
The Tommee Tippee Double Electric Breast Pump (DEBP) complies with the
requirements of applicable EMC standards. Other electronic equipment exceeding
the limits defined in such EMC standards such as mobile telephones & wireless
devices, could affect the operation of the device. MODEL 1092 needs special
precautions regarding EMC and needs to be installed and put into service
according to the EMC information provided in the ACCOMPANYING DOCUMENTS.
Portable and mobile RF communications equipment can affect MODEL 1092.
ADAPTER
Input: 100-240VAC 50/60Hz 400mA
Output: DC 9.5V 1.2A
KEEP AWAY FROM SUNLIGHT
HELPFUL ADVICE
-
There should be no pain using your breast pump. If you feel pain, try using the pump more gently. Then examine your breasts. If there are
any red or hot areas contact your breastfeeding advisor as soon as possible. -
Suction onto the breast can be broken by inserting your finger between the breast and the horn.
-
Do not continue to use the pump once your milk has stopped flowing.
-
Remember you are only trying to express milk from just behind the nipple – strong suction is not necessary.
-
The best time to use your breast pump is after the first feed of the day (unless otherwise advised by your breastfeeding advisor).
-
Be comfortable and relax, eg. Watch the TV or have your favorite music playing.
-
Wash all breastfeeding equipment after use and before sterilization.
-
Do not place furniture or other obstructions on the adapter cords and be sure to position them so that nobody can trip over them.
-
Keep adapter cords away from hot surfaces such as radiators and central heating pipes.
-
Always position the adapter and cord well out of reach of your baby and any young children. Be careful not to position the adapter where a child might try to step on it.
-
Never use the Tommee Tippee breast pump adapter with any other equipment. Nor should you use any other adapters with your Tommee Tippee breast pump.
-
The adapter converts your AC power to a safe low DC voltage.
TROUBLESHOOTING
IF THERE IS LOW OR NO SUCTION:
Make sure all connections are secure. Make sure the silicone inserts on the
horns form a complete seal around both breasts. Check the valve is clean and
not damaged. Make sure the air tube is securely fitted to the upper pump body
and the motor unit. Check there is no kink in the air tube. Make sure the
diaphragm is assembled correctly and the cap is firmly in place . Check the
connector is in the central position.
IF PUMP WILL NOT TURN ON:
Make sure the pump is plugged in correctly. Make sure it is switched on and
the display lights up. If using the battery, make sure it is installed
correctly and is fully charged.
WARRANTY
The adapter and motor unit have a warranty period of 12 months from date of
purchase. The battery has a warranty period of 6 months from date of purchase.
The manufacturer is not liable for any wear and tear or any damage caused by
incorrect or inappropriate usage or use by unauthorized persons. Use by more
than one person will invalidate the warranty and may present a health risk.
SING THE MILK PROTECTION PODS AND TRAY
For use with the Tommee Tippee® closer to nature® breast pumps
HOW TO USE
-
Ensure pod is clean and sterilized.
-
Remove lid and place milk protection pod inside the bottle.
-
Screw bottle onto bottle neck adapter and continue to follow assembly of breast pump instructions.
-
When the breast pump is fully assembled and in use, the smaller pod will hold up to 2 oz and the larger pot will hold up to 4 oz.
-
IF USING THE SMALLER POD : Once you have expressed 2 oz stop pumping, place lid on storage pod and remove from bottle.
IF USING THE LARGER POD : Once you have expressed 4 oz stop pumping, place lid on storage pod and remove from bottle. -
Place pod in the tray and transport to either refrigerator or freezer for storage. See STORAGE OF BREAST MILK guide below.
-
If you want to continue expressing, either insert another clean and sterilized pod or express directly into the bottle of the breast pump.
-
Thaw frozen milk placing the pod into the bottle filled with warm water.
QUICK START GUIDE
STORAGE OF BREAST MILK
a. Refrigerate expressed milk immediately. If you express more than once a
day, you can add the amounts so long as you put it back in the refrigerator
each time.
b. Store milk in the refrigerator for up to 24 hours, or in the freezer for 3
months.
c. You will notice that stored milk separates out into layers. Shake to remix
thoroughly before feeding.
d. When freezing milk, allow space at the top of the bottle for expansion. It
is easiest to freeze milk in individual feed quantities of 60-125ml (2-4ozs)
e. Thaw frozen milk in the refrigerator or by standing the bottle in warm
water until it has reached body temperature.
f. If you want to take expressed milk with you when you are out, make sure it
stays cold or frozen until needed.
USING MILK PROTECTION PODS AS A SIPPY CUP
- If milk has been chilled, remove lid and place in warm water to heat to temperature required. Always check food temperature before feeding. Sit baby upright.
- Hold cup up to baby’s mouth and gently tip to allow baby to sip from cup.
FOR YOUR CHILD’S SAFETY AND HEALTH WARNING!
Always use this product with adult supervision. Accidents have occurred when babies have been left alone with drinking equipment due to the baby falling or if the product has disassembled. Always check food temperature before feeding. Heating in a microwave oven may produce localized high temperatures. Take extra care when microwave heating. Always stir heated food to ensure eve heat distribution and test the temperature before serving.
CLEANING
• Before first use, clean the product.
• Clean before each use.
• Always wash the product immediately after use.
• Wash in warm soapy water and rinse in clean water or use a dishwasher. Do
not clean with solvents or harsh chemicals.
• Do not allow product to come into contact with oil based foods (e.g.
oil/tomato based sauces) as staining will occur.
STERILIZING
• Suitable for sterilization by steam (electric and microwave), boiling or cold water tablet/liquid solution.
STORAGE AND USE
• Inspect before each use. Throw away at the first signs of damage or
weakness.
• Do not store or leave in direct sunlight or near a source of heat.
• Do not store with or allow to come into contact with solvents or harsh
chemicals.
• Not suitable for use in a conventional oven or a combination microwave oven
with the grill feature switched on.
• Keep all components not in use out of reach of children.
For best results make sure this valve can open
closer to nature® bottle & nipple
Before using your closer to nature bottles or nipples, please ensure that you
read these instructions thoroughly.
Please keep this instruction sheet for future reference as it includes
important information.
FOR YOUR CHILD’S SAFETY AND HEALTH
WARNING!
Always use this product with adult supervision. Do not leave baby alone with
drinking equipment due to the risk of choking, baby falling or if the product
has disassembled.
Never use feeding nipples as a pacifier. Continuous and prolonged sucking of
fluids will cause tooth decay.
Tooth decay in young children can occur even when non-sweetened fluids are
used. This can occur if the baby is allowed to use the bottle for long periods
through the day and particularly through the night, when saliva flow is
reduced or if it is used as a pacifier.
Always check food temperature before feeding. Do not heat in a microwave.
Always stir heated food to ensure even heat distribution and test the
temperature before serving. For your child’s safety – Always check food
temperature before feeding by testing on a sensitive part of your skin. For
example on the inside of your wrist.When making up a feed follow the formula
milk manufacturer’s instructions and allow the freshly boiled water to cool
before pouring it into the bottle.
CLEANING
- Before first use, clean the product.
- Clean before each use.
- Always was the product immediately after use.
- Wash in hot soapy water and rinse in clean water or use a sterilizer after washing.
- Do not clean with solvents or harsh chemicals.
- Top-rack dishwasher safe.
- Do not allow product to come into contact with oil based foods (e.g. oil/tomato based sauces) as staining will occur.
- Do not turn the nipple inside out for cleaning. Damage could result.
- Do not use a bottle brush. Only the nipple and spout cleaner of the closer nature Bottle & Nipple Brush is suitable.
TAKE EXTRA CARE WHEN CLEANING THE SENSITIVE ANTI-COLIC NIPPLE VALVE
In order to ensure optimum venting the nipple valve is manufactured using a thinner silicone than the nipple itself and therefore care needs to be taken during cleaning to ensure no damage is caused. Do not use a bottle brush or any other implement to clean the anti-colic valve as this may split and damage it. However, the performance of the nipple may be affected if the anti-colic valve is not cleaned thoroughly after each use. Ensure valve is flushed with warm water during cleaning.
STERILIZING
Before first use place in boiling water for 5 minutes. This is to ensure hygiene. Suitable for steam sterilization.
- After each use disassemble all parts of the bottle.
- Wash thoroughly with hot soapy water.
- Rinse all components using freshwater.
- After rinsing, re-assemble the nipple and screw ring.
- Place all components including the nipple and screw ring assembly in the sterilizer. The closer to nature microwave or electric sterilizer are suitable. After sterilization, the nipple can then be picked up using the screw ring as normal.
ASSEMBLY OF YOUR NIPPLE AND SCREW RING
- Due to the larger size of Tommee Tippee’s nipple and screw ring, care needs to be taken during assembly to ensure that the nipple is in the correct position (shown below).
- The best method of assembly of the nipple and screw ring is to carefully pull the nipple through the ring in different directions to ensure the silicone lip fully clips’ over the edge of the screw ring. The area where the nipple and screw ring meet should be flush.
**STORAGE AND USE
**
Inspect before each use and pull the feeding nipple in all directions. Throw
away at the first signs of damage or weakness. Do not leave a feeding nipple
in direct sunlight or heat, or leave in disinfectant (“sterilizing solution”)
for longer than recommended, as this may weaken the nipple. Do not store with
or allow to come into contact with solvents or harsh chemicals. Not suitable
for use in a grill or a microwave oven with the grill feature switched on.
Keep all components not in use out of reach of children. For safety and
hygiene reasons it is recommended the feeding nipple is replaced at least
every 2 months. Do not heat in a microwave. This product is for home use, and
is not suitable for use in the presence of a FLAMMABLE ANAESTHETIC MIXTURE
WITH AIR or WITH OXYGEN OR NITROUS OXIDE.
Tommee Tippee closer to nature Double Electric Breast Pump Instruction Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>