Congratulations on your purchase of Mosquito Magnet ® . Now you can begin to
enjoy your outdoor living space again. Mosquito Magnet ® is the #1 mosquito
trap in North America. Backed by 18 years of research and independent
testing, Mosquito Magnet ® is scientifically proven to effectively reduce
mosquitoes & other biting insects from your yard. Mosquito Magnet ® is easy
to use. The link
www.mosquitomagnet.com/videos provides
key information for getting started. In this manual, you’ll learn everything
you need to know about how it works, optimal trap placement, maintenance,
storage and warranty information. The keys to success are trap placement,
utilization of the correct attractant for your area and routine maintenance.
For optimal catch rate, you’ll need to change the propane tank and attractant
every 21 days.
Our Customer Care line is available to answer all your questions regarding
your new purchase. Please feel free to contact us…
Customer Care: 1-800-953-5737
Visit us online at www.mosquitomagnet.com for
additional information regarding Mosquito Magnet® tips, testimonials, and
additional product offerings.
Woodstream® Corporation
69 North Locust Street
Lititz, PA 17543
1-800-953-5737
www.mosquitomagnet.com
The Mosquito Magnet® traps are covered by one or more of the following
patents:
USA Nos. 5,813,166; 6,145,243; 6,286,249; 6,817,140;6,840,005; 6,848,466;
6,892,492; 7,074,830; 7,243,458; 7,281,351; 7,293,387; 7,536,824; 7,614,180;
7,752,803; 7,987,631; 8,067,469; 8,051,601 and 8,141,291
Other patents pending
Made in China
FOR YOUR SAFETY
If you smell gas:
- Shut off the gas to the appliance.
- Extinguish any open flame.
- Open lid.
- If odor continues, immediately call your gas supplier or your fire department.
FOR YOUR SAFETY
1. Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity
of this or any other appliance.
Questions or Comments
Please contact Woodstream ® Corporation if you have any questions or
experience any problems with your Mosquito Magnet ®:
1-800-953-5737
Woodstream ® Corporation 69 North Locust Street Lititz, PA 17543
www.mosquitomagnet.com
Model No.:
Serial No.:| Patriot Plus
---|---
Type of Gas:| Propane
Manifold Pressure:| 100 – 110 psi
Minimum Gas
Supply Pressure:| 11.0 in. WC
Input Rating:| 650 Btu/Hr.
Minimum Clearances:| 20 – 24”
How the Mosquito Magnet ® Works
Mosquitoes and other biting insects use the long-range attractant carbon
dioxide (CO2) to locate people. Once in close proximity, mosquitoes use short-
range attractants such as scents emitted from the skin, to determine which
person they are going to bite. The Mosquito Magnet ® mimics a human by
converting propane to CO2, with its patented catalytic conversion technology,
in combination with a short-range attractant.
Attracted by the CO2 and short-range attractant, mosquitoes, and other biting
insects are drawn to the Mosquito Magnet ® . When they reach the trap, the
insects are vacuumed into a bug bag by our patented Counterflow Technology™,
where they dehydrate and die within 24 hours. The Mosquito Magnet ® is silent,
odorless, and runs 24/7.
When properly placed in your yard, the trap begins working immediately.
Noticeable results can be achieved in 7 to 10 days. To greatly reduce your
biting insect population, allow 4 weeks. Leave the Mosquito Magnet ® out all
summer long, to control the mosquito population in your yard.
Only biting insects are targeted including mosquitoes, no-see-ums, black
flies, and midges. Beneficial insects such as butterflies, bees or moths are
not targeted.
Safety Instructions
Please read and follow all safety instructions and warnings.
Children and adults should be alerted to the hazards of high surface
temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of
the trap. Keep out of reach of children.
Clothing or other flammable materials should not be hung from the heater or
placed on or near the trap.
Note: Some or all of the following required safety instructions for propane-
powered devices may apply to your trap. Allow trap to cool for 5 minutes
before re-starting. Warning: **Warning: Improper installation,
adjustment, alteration, service or maintenance can cause injury or property
damage. Read the installation, operating, and maintenance instructions
thoroughly before installing or servicing the trap.
Caution:** The gas pressure regulator
provided with this appliance must be used.
This regulator is set for an outlet pressure of 11.0 in. Water Column.
The minimum inlet gas supply pressure is 11.0 in. Water Column from the
regulator.
- This unit is not intended to be installed in or on recreational vehicles and/or boats.
- The gas supply must be turned off at the LP-Gas supply cylinder when this appliance is not in use.
- The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223. 1-1998 for US and with the CAN1-B149 for Canada.
- To test for a gas leak, place soapy water around the connector, regulator, and gas hose assembly. If bubbles appear, there is a gas leak.
- Inspect the hose before each use of the unit. If it is evident there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the unit being put into operation. The replacement hose shall be that specified by the manufacturer.
- The trap is equipped with an internal spark ignition device. Failure to follow starting procedure will result in the trap not starting.
- Installation and repair should be done by a qualified service person (find service centers on www.mosquitomagnet.com). The trap should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that the control compartment, burners, and circulating air passageways of the heater be kept clean.
- Maintain adequate clearances of 20”–24” around air openings into the combustion chamber, clearances from combustible material, provisions for accessibility, and for combustion and ventilating air supply. Keep the trap area clear and free from combustible materials, gasoline, and other flammable vapors, and liquids. The appliance is not to be used in locations where flammable vapor or explosive dust is likely to exist.
- Do not obstruct the flow of combustion and ventilation air.
- Keep the ventilating openings of the cylinder enclosure free and clear from debris.
- Clean the trap with water and a damp cloth if necessary.
- A maximum of 20 lb. LP-Gas cylinder shall be used.
- The LP-Gas cylinder must be provided with a shut-off valve terminating in an LP-Gas supply cylinder valve outlet specified for Connection No. 510 in the Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections, ANSI/CGA-V-1-1977.
- The LP-Gas cylinder supply system must be arranged for vapor withdrawal and the cylinder must include a collar to protect the cylinder valve.
- The LP-Gas cylinder used shall be constructed and marked in accordance with the specifications for LP-Gas cylinders of the U.S. Department of Transportation (DOT) or The National Standard of Canada CAN/CSA-B339.
- The trap shall be used outdoors only in a well-ventilated space and shall not be used in a building, garage, or any other enclosed area.
- The LP-Gas cylinder must be disconnected and removed from the appliance if the appliance is stored indoors.
- LP-Gas cylinders must be stored outdoors in a well-ventilated area out of reach of children.
- Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building, garage, or any other enclosed area.
- The pressure regulator and hose assembly supplied with this appliance must be used for connection to the LP-Gas cylinder. Replacement pressure regulators and hose assemblies must be specified by the manufacturer.
- Avoid improper use of extension cords. Keep connections away from moisture and avoid damage to the cord.
- If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid hazard.
Please contact Customer Care if you have any questions at:
1-800-953-5737
or visit www.mosquitomagnet.com
Warning: SHOCK! An electric shock hazard may exist if water from a garden
hose is directed at the Mosquito Magnet ® . Route the power cord in the safest
possible manner to avoid personal injury.
Principle Parts
Assembly Instructions
Step 1
Place base upside down on a flat surface, slide U-shaped support legs into
slots on base until they lock in place.
Step 2
Turn base and leg assembly right-side-up and place support pole into cavity on
base.
Step 3
Place trap powerhead onto pole. Press down firmly with two hands to secure.
Step 4
Completed assembly should have the front of the powerhead in the same
direction as base U-shaped legs.
Step 5
Insert attractant as directed in attractant packaging.
Step 6
Place the base of the propane tank into the molded cradle supplied.
Step 7
Making sure the propane tank is fully closed, attach propane regulator hose to
a propane tank. Secure tightly by hand. Do not use tools.
Step 8
Plug power connector into the trap power slot located on the back of the power
head.
Step 9
Plug Adapter into a properly grounded electrical outlet.
Step 10
Turn the propane valve on slowly. See page 8 for propane tank installation.
Set-Up
Trap Placement
-
Determine the direction of the prevailing wind.
Check local weather patterns if you are unsure. -
Stand in the center of the area you are trying to protect and look toward the prevailing wind.
-
Proper placement of the trap will be 30 – 40 feet in front of you, within 5-6 feet of ground cover (i.e. bushes, flowerbeds, tree line, marsh bed). Ensure that trap is not
directed against any blockades such as buildings, fences, etc. -
It is recommended that the trap be placed in the shade.
-
Do not place trap directly above a water source (sprinklers, hose, etc.).
-
Trap must be placed on level ground to avoid tipping or uneven propane distribution.
-
For optimal trap placement in your yard, refer to the instructional video at www.mosquitomagnet.com/videos to build your own yard diagram for correct trap placement.
Burying the Power Cord
Make sure unit is unplugged and in the proper position. Use the Cord Burying
Clips supplied. Place clips approximately 3 feet apart, press into ground by
hand making sure not to damage power cord. For alternate placement, follow
steps illustrated below.
1. Use a straightedge shovel or garden spade and dig a trench about 3”- 4”
deep from power source to trap.
2. Place cord into trench carefully stretching as you go to remove any twists
in cord.
3. Use cedar shingle or folded cardboard to place cord into the bottom of the
trench. Recover the trench with the removed soil.
| |
---|---|---
Propane Tank Installation
- After the trap is placed in its ideal location, place the propane tank onto the molded cradle.
- Make sure the propane tank is fully closed. Attach propane regulator hose to a propane tank. Secure tightly by hand. Do not use tools.
- Turn propane on by slowly turning the valve counter-clockwise. Take care not to turn too quickly to avoid engagement of the safety valve.
DO NOT MOVE TRAP WITH TANK ATTACHED!
TANK MUST BE DISCONNECTED FROM REGULATOR BEFORE TRAP IS RELOCATED TO AVOID
DAMAGE TO REGULATOR AND/OR TRAP. BE ADVISED, DAMAGE CAUSED BY FAILURE TO
COMPLY WITH THIS INSTRUCTION IS NOT COVERED UNDER WARRANTY.
| |
---|---|---
Step 1 – Propane Tank Placement| Step 2 – Attach Regulator|
Step 3 – Slowly Open Valve
USING THE CORRECT ATTRACTANT OPTIMIZES THE CATCH RATE OF YOUR TRAP.
Mosquito Magnet®Octenol
-
If you live in the northern half of the U.S., or along with any coastal areas in the U.S., use a fresh Mosquito Magnet ® Octenol cartridge every time you change the propane tank.
Lurex3™ -
If you live in the southern half of the U.S., the Asian Tiger a mosquito may be the predominant species in your area.
-
Lurex3 TM is an attractant specially designed to capture hard-to-catch and aggressive, day-biting species such as the Asian Tiger mosquito.
-
To find out if Lurex3 TM is right for you, go to www.mosquitomagnet.com/lurex.
Use a fresh Lurex3 TM cartridge every time you change the propane tank.
- Octenol Attractant Installation
1. Locate Mosquito Magnet® Octenol Biting Insect Attractant. Remove mosquito attractant packet from bag. Carefully peel back foil cover
2. Locate the Octenol carrier compartment inside the plume tube.
Turn cap counter-clockwise about 1/8 turn. Remove end cap.
3. Place the open packet of mosquito attractants into the carrier compartment.
4. Replace end cap on carrier compartment. Be sure to align the cap’s “feet” with grooves inside carrier compartment. Secure cap by turning clockwise until it clicks (about 1/8 turn).
Precautionary Statements
Hazards to Humans and Domestic Animals.
Caution: Harmful if swallowed. Avoid contact of skin, eyes or mouth with the evaporation holes. Wash hands before eating, drinking, chewing gum, using tobacco or using bathroom facilities.
First Aid
If swallowed
- Call the poison control center or doctor immediately for treatment advice.
- Have person sip a glass of water if able to swallow.
- Do not induce vomiting unless told to do so by the poison control center or doctor.
- Do not give anything by mouth to an unconscious person.
If on skin or clothing
- Take off contaminated clothing.
- Rinse skin immediately with plenty of water for 15-20 minutes.
- Call a poison control center or doctor for treatment advice.
If in eyes
- Hold eye open and rinse slowly and gently with water for 15-20 minutes.
- Remove contact lenses, if present, after the first 5 minutes, then continue rinsing eye.
- Call a poison control center or doctor for treatment advice.
If inhaled
- Move person to fresh air.
- If a person is not breathing, call 911 or an ambulance, then give artificial respiration, preferably by mouth-to-mouth, if possible.
- Call a poison control center or doctor for treatment advice.
Have the product container or label with you when calling a poison control center or doctor, or going for treatment.
Environmental Hazards: Do not apply directly to water. Do not contaminate
water when disposing of equipment wash waters or rinsate.
Directions for Use
It is a violation of federal law to use this product in a manner inconsistent
with its labeling.
**Replace cartridge every 21 days** (Note: After 21 days of use, cartridge
appears the same; however, it will no longer be effective as the Octenol will
have been released.)
Based on release rate studies conducted at a constant ambient air temperature of 80˚ F for 21 days. Octenol release from this product will be more rapid at higher ambient air temperature.
Storage & Disposal
Do not contaminate water, food or feed by storage or disposal.
Storage: Store unopened attractant cartridge in a cool, dry place.
Discard the outer plastic bag in the trash.
Disposal: Do not reuse attractant cartridges.
Dispose of used attractant cartridges in the trash.
| | |
---|---|---|---
Instructions
READ MANUAL BEFORE STARTING
Starting Instructions
It is recommended that you read the entire manual before starting the Mosquito
Magnet ®trap.
1. Insert attractant in compartment per instructions in attractant packaging.
2. Connect the regulator to propane tank (see page 8).
3. Plug power connector into the trap.
4. Plug AC adapter into an electrical socket. (To avoid the risk of
electrical shock, connect only to properly grounded outlets.) The adapter unit
is not intended to be mounted.
5. Slowly turn the propane tank valve on.
6. Turn rocker switch to “on” position.
7. The red light on the switch will flash for up to 20 minutes (warm-up
phase).
8. Once the light stops flashing and is solid, the Mosquito Magnet ® is fully
operational.
NOTE: Should you experience an interruption of power, be sure to restart the
trap.
Shut Down Instructions
To shut down the Mosquito Magnet ® simply close the valve on the propane tank
and switch to the “off” position.
When Not In Use
If the unit is not in use, the gas must be turned off at the supply cylinder.
Storage of this unit indoors is permissible only if the cylinder is
disconnected and removed. Cylinders must be stored outdoors, out of reach of
children and must not be stored in a building, garage or any other enclosed
area.
End of Season Storage
Push ON/OFF switch to OFF position to shut down the trap.
The LED light will go out and the fan will continue running until trap is
cool. Close the propane tank valve and disconnect regulator.
Any open Mosquito Magnet ® attractant should be removed and discarded. See
attractant label for disposal instructions.
The bug bag should also be discarded prior to storing the trap.
STORAGE: The trap should be stored indoors in a garage or shed in the
off-season. Cover trumpet to prohibit insects from nesting. Cover unit with a
tarp and secure tightly at the bottom to keep out dust, spider webs and other
debris.
For Best Results (unit must run for 24 hours/day)
- Your trap will begin capturing immediately with a significant reduction in the mosquito population in 7-10 days. Allow 4 weeks to significantly reduce the mosquito population in your yard.
- Allow trap to cool for 5 minutes before restart.
- Never spray insecticide in or around the trap.
- Trap can be left running in the rain.
- If using lime or fertilizer compounds, be sure to shut down the trap first to prevent dust or fine mist from being drawn into trap and clogging bug bag.
Warning: Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Read the installation,
operating, and maintenance instructions thoroughly before installing or
servicing this equipment.
Caution: The gas pressure regulator provided with this
appliance must be used. This regulator is set for an outlet pressure of 11.0
in. water column.
The gas supply must be turned off at the LP-Gas supply cylinder when this
appliance is not in use.
Leader in 360º Customer Support
-
Customer Care Hotline: 1-800-953-5737
-
Online Product Registration Available
-
Visit www.mosquitomagnet.com for
Troubleshooting Tips/Trap Placement -
Certified Service Locations – Information Available at www.mosquitomagnet.com
Maintenance
-
21 Day Maintenance Cycle
– Refill propane. (Propane lasts approximately 21 days with 24-hour/7-days operation.)
– Replace short-range attractant cartridge.
See Mosquito Magnet ® attractant label for instructions.
– Empty or replace bug bag. -
Periodically wipe down the outside of the trap with clean water and a damp cloth.
Propane Tank Changing Time
When attaching the regulator knob to a tank after a tank change, be sure to
fully tighten the regulator knob onto the tank. No need to use tools, but do
turn the knob as far as possible by hand. When this is done, loosen the knob
1/4 turn,then re-tighten to maximize seal.
The purpose for this is to fully engage the regulator onto the tank. If the
regulator is not fully engaged, the flow of gas may be restricted to the point
where the trap will show a gas empty code. If this occurs, press the off
button, close the tank valve, and remove the regulator from the tank. Re-
attach the regulator and try again.
Troubleshooting
Problem | Possible Cause | Solutions |
---|---|---|
Your Mosquito Magnet ® won’t tart | 1. Is the propane tank empty? |
2. If the propane tank is new, it may have air blockage, has it been purged?
3. If tank has been opened too quickly, security check valve may have
triggered.
4. Is the power cord plugged in?
5. Is there a loose connection?
6. The outdoor temperature is below 50˚F (10˚C).
7. The tank regulator isn’t fully engaged.
8. Propane tank may be empty or need to be purged.
9. Regulator is not fully engaged.| 1. Weigh tank and check against “empty”
weight
written on tank.
2. Bring tank to filling location. Air may be in
fuel line. Ask for tank to be purged.
Hint: If you have another propane powereddevice operating on a standard, 20 lb
propane
tank, try hooking that tank up to the trap toverify that the issue is with
your tank.
3. Disconnect the regulator from the tank and
reconnect. Then open the regulator valve slowly.
4. Verify all electrical connections. Make sure you are
using the correct power requirements for your unit.
5. Make sure regulator is fully engaged, and propane
tank valve is fully open.
6. Mosquitoes are not active at this climate; wait
until the temperature is consistently above 50° F
(10˚C) before starting your trip.
7. Make sure the regulator is fully engaged, and
The propane tank valve is fully open.
8. Go through above steps 1, 2, and 3.
9. See tank changing tips on page 12. Hand
tighten the propane tank regulator until
slightly snug.
Low or no catch| 11. Insects may not be out yet.
12. Trap improperly placed.
13. Biting insect’s reproductive cycles have not
yet been broken.| 11. Verify temperature is consistently above 50˚F (10˚C).
12. Follow steps in the “Trap Placement” section of
your owner’s manual or go to
www.mosquitomagnet.com “Placement” section.
13. Keep trap in constant operation 24 hours/day,
7 days/week for 4 weeks to interrupt the breeding cycle.
Customer Care Please have your serial number, date of purchase & model type
available
All of us at Woodstream®
Corporations want you to get complete satisfaction from your trap. Should you
have any problems you cannot
resolve, simply call one of our trained Customer Service Representatives at
1-800-953-5737 or visit
www.mosquitomagnet.com.
We will help you get up and running.
Limited Warranty
Limited Warranty
This warranty, (1) year from the purchase of the unit, is extended only to the
original purchaser/user of products. This limited warranty begins on the
original date of purchase, and is valid only on products purchased and used
in the United States.
Woodstream® Corporation warrants its products to be free from defects in
materials and workmanship for the warranty period by the original
purchaser/user.
For warranty service, please contact our Customer Care
800-953-5737. Please indicate the
nature of the defect. Warranty service can only be performed by a Mosquito
Magnet ® Certified Service Center.
If Woodstream ® Corporation determines there may be a defect, Woodstream ®
The corporation will issue a Return Goods Authorization (RGA) number. The
defective unit or parts must be returned for warranty inspection using the RGA
number, when applicable, as identification within (30) days of the return
authorization date. DO NOT return products to our factory without our prior
consent, as they, as well as C.O.D. shipments will be refused. Woodstream ®
Corporation or agent, at its option, shall replace the unit, replace the
defective part(s) and return such unit to you. Woodstream ® Corporation’s sole
obligation and your exclusive remedy under this warranty shall be limited to
such replacement.
Limitations and Exclusions:
The warranty shall not apply to problems arising from normal wear, or failure
to adhere to the enclosed instructions. In addition, the foregoing warranty
shall not apply to serial numbered products if the serial number has been
removed or defaced; products subject to negligence, accident, improper
operation, maintenance or storage; products damaged by circumstances beyond
Woodstream ® Corporation’s control; or products modified (including, but not
limited to modifications through the use of unauthorized parts or attachments)
or repaired by anyone other than Woodstream ® A corporation or its designee.
The foregoing warranty is exclusive and in lieu of all other warranties,
express or implied, including without limitation the implied warranties of
merchantability and fitness for a
particular purpose. It shall not extend beyond the duration of the express
warranty provided herein, and the remedy for violations of any warranty shall
be limited to repair or replacement of the defective product pursuant to the
terms contained herein. Woodstream ® Corporation shall not be liable for any
consequential or incidental damages whatsoever.
This warranty gives you specific legal rights and you may also have other
legal rights which may vary based on location.
Product Registration
Register on-line at www.mosquitomagnet.com or mail completed form today.
First Name …………………… Last ……………
Address
City………………………………State/Province………………….. Zip ………….. Country………..
Phone Number…………….Email Address ………….. Yes, I would like to receive product
updates via email
1. Where did you buy this product?
Website. Store Name Service Center
2. How did you find out about the Mosquito Magnet®? (check all that apply)
Radio Ad
Direct Mail
TV Ad
Friend/Family
Website Magazine Ad| Newspaper Ad
News Article (newspaper, magazine, TV, etc.)
Catalog
In-Store Display
Other
---|---
3. In your household who decided to purchase the Mosquito Magnet ® ?
Male Female Both
4. What is your marital status?
Married Single
5. Are there any children in your household?
Yes No
6. What are the two most important reasons influencing this purchase?
Protection from mosquitoes that may transmit disease Comfort
Science/technology behind product Received as gift
Recommendation of friend/family member Other
Recommendation of salesperson
7. What is your age?
25 – 35 36 – 45 46 – 55 56 – 65 66+
8. What is your level of education?
High School Diploma College Degree Graduate Degree Doctoral Degree
Technical/Professional
9. What is your annual household income?
$25,000 – 39,999 $40,000 – 59,999 $60,000 – 89,999 Over $90,000
10. What other brands of insect abatement have you tried?
Zappers Sprays Pesticides Other CO2 Traps, Name:
11. Would you consider giving a testimonial once you are thoroughly convinced
of the effectiveness of the Mosquito Magnet ® ?
Yes No
12. Were the assembly directions and operation instructions explained clearly
and simply?
Yes No
NECESSARY INFORMATION
In order to properly register your product with Woodstream® Corporation, the
following information is required.
Model: Circle One
Patriot Plus Independence Executive
Serial#:
Date of purchase…
Please visit www.mosquitomagnet.com
to find a local Certified Service Location.
Consumer Confidentiality: All of the information that has been gathered on
this reply card is solely for the internal sales and marketing efforts of
Woodstream® Corporation. None of the information that you may have provided
will be sold, rented or leased to any other company, organization or agency
for any purpose whatsoever. None of this information will be posted on our
company website or any other vehicle that can be obtained by the public
domain. If you wish to make additional comments or testimonials about our
product, please address them separately and send them to our Marketing
Department at the address listed inside the manual.
References
- Mosquito Magnet® | Mosquito Traps To Protect Your Home Or Business
- What Attracts Mosquitoes | How To Use Attractants
- Videos and Demos
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>