CFP HUBBELL Lighting Instruction Manual
- June 7, 2024
- CFP
Table of Contents
CFP HUBBELL Lighting Instruction Manual
Instruction
NOTE:
Components shown in images are representative only and may vary based on the
configuration ordered.
CAUTION:
Read instructions carefully and turn electricity off at main circuit breaker
panel before beginning installation.
WARNING:
If any special control devices are used with this luminaire, follow the
instructions carefully to assure full compliance with NEC requirements. If
there are any questions, contact a qualified electrical contractor.
WARNING:
This product contains chemicals known to the State of California to cause
cancer, birth defects and/or other reproductive harm. Thoroughly wash hands
after installing, handling, cleaning, or otherwise touching this product.
INSTALLATION METHOD
1: RECESSED MOUNTING
-
STEP 1
Raise unit into ceiling
-
STEP 2
Bend T-bar clips into position.
2: LUMINAIRE FITTING
-
STEP 1
Snap corner bracket to extruded rails, making sure that mounting flanges are on opposite sides.
-
STEP 2
Attach frame to ceiling structure.
-
STEP 3
Remove one non-mounting frame side and slide in flat-panel. Make all electrical connections using appropriate fittings.
-
STEP 4
Reinstall frame side to complete.
WIRING CONNECTION
***** Wiring connection of both installation methods are the same
-
STEP 1
Open access plate. Use knockouts to connect power access using appropriately- sized electrical fittings.
-
STEP 2
Make wiring connections.
LUMEN SELECTABLE INSTRUCTIONS
Different lumen levels can be achieved by setting the switch on the driver cover to different positions
For 38W Product
2800/3300/4000 Lumens
For 52W Product
3400/4100/5500 Lumens