iPolar 3339R-SGP SkyGuider Pro Installation Guide
- June 7, 2024
- ipolar
Table of Contents
iPolar 3339R-SGP SkyGuider Pro Installation Guide
Tool needed:
A set of metric hex key wrench
-
Loosen two screws at the front of the mount and two others on the top of a SkyGuider Pro main board cover and remove the black cover.
-
Unplug the 6-wire motor driver cable and DC power cable. Remember how wires wrapped.
-
Remove two mounting screws.
-
Gently pull the circuit board with sockets end up and slide the circuit board out. If the board is stuck by the motor, loosen two Phillips screws hold the motor.
-
Unscrew and remove the polar scope LED board and disconnect wire harness from the main board.
-
Remove polar scope cover and base.
-
Rotate the RA axis to find TWO set screws 90 degree apart next to the LED board, which are used to secure the polar scope in place. Use a 1.5mm hex key to release the set screws.
-
Pull the polar scope out of the RA axis.
-
Insert the iPolar into the RA axis. Rotate it to align the USB port to the DEC bracket. Lock the set screw gently to secure the iPolar.
-
Replace the Polar Scope base plate with a new one with larger opening, if your SkyGudier Pro is an earlier version.
-
Sliding the front end of the control board in.
-
Gently push the board in when the power cable goes through the small cut on the board.
-
If you release the motor to gain more space while remove the board, tighten motor locking screws while push the motor against worm assembly to tension the belt properly.
-
When securing the board with two screws, make sure that the battery and wires underneath are properly seated. Fully tighten the screws.
-
. Plug in the battery wire and motor cable. Refer to step 2 to wrap the wire properly. Put the cover and screws on.
-
Follow iPolar Operation Manual to perform the polar alignment. Use quick slew button to rotate the SkyGuider Pro RA axis during camera center calibration.