Whynter ARC-14SH Eco-Friendly 14000 BTU Portable Air Conditioner with Heater Instruction Manual
- June 7, 2024
- Whynter
Table of Contents
- DISPOSAL
- SAFETY PRECAUTIONS
- OPERATING CONDITION
- IDENTIFICATION OF ACCESSORIES
- IDENTIFICATION OF PARTS
- OPERATING YOUR AIR CONDITIONER
- INSTALLATION INSTRUCTIONS
- AIR FILTERS INSTALLATION
- OPERATION INSTRUCTIONS
- CARE AND MAINTENANCE
- TECHNICAL DATA
- TROUBLESHOOTING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER
MODEL#: ARC-14SH
Instruction Manual
Congratulations on your new WHYNTER product. To ensure proper operation,
please read this Instruction
Manual carefully before using this product. Keep this manual in a safe place
for future reference.
Thank you for choosing the Whynter portable air conditioner. Please follow the
instructions provided in this user guide to obtain the very best performance
from your portable air conditioner and take full advantage of the many
features your portable air conditioner offers you. We trust that your Whynter
air conditioner will provide the performance and reliability that we stand
for.
Please keep this user manual in a safe place for future reference.
DISPOSAL
This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment. Further information about the recycling of this product can be obtained from your local municipal authority.
Your safety and the safety of others are very important to us.
To reduce the risk of fire, electrical shock, or injury when using your
appliance, follow these basic precautions.
SAFETY PRECAUTIONS
Before the portable air conditioner is used, it must be properly positioned
and installed as detailed in this manual.
-
Do not under any circumstances cut or remove the third (ground) prong from the power cord.
-
Make sure this unit is connected to a correctly grounded power supply outlet. Do not use an extension cord or power strip.
-
The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to a power source.
-
It is recommended to use a separate circuit that size should be 15 Amps for the air conditioner.
-
Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air conditioner.
-
To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas.
-
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances.
-
Do not repair, disassemble and/or modify the unit by yourself.
-
Always turn off the portable air conditioner when cleaning the air filter, and transporting.
-
Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch.
-
Transport the unit in an upright position only, or leave it in an upright position for a minimum of 4 hours before first use.
-
Ensure curtains or other objects are not obstructing the air inlet filters.
-
Do not bend or crush the exhaust hose while in use.
-
Always allow at least 20″ of clearance around the unit for ventilation. Do not use this unit inside closets, cabinets, and/or cramped spaces between furniture.
-
This unit is optimized to operate at an ambient temperature of 64 F.
-
This unit must be installed in an area protected from the element, such as wind, rain, water spray, or drips.
-
The unit should not be located next to ovens, grills, or other sources of high heat.
-
Always place the unit on an even and hard and level surface.
-
Do not sit or place objects on the unit.
-
Do not allow children to climb, stand or hang on the unit. The air conditioner could tip over and get damaged and/or seriously injure somebody.
-
Keep fingers out of the air intakes and air outlets.
-
A unit is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface, or while standing in water. Do not use it in outdoors or in wet conditions.
-
When positioning or moving the unit, ensure it is not turned upside down or greater than 45°or more off level.
-
This unit is designed for household, non-commercial use only. Any other use will void the warranty.
-
Do not plug into the power outlet before set up is completed.
-
Do not operate this unit without the air filter(s).
-
Do not use harsh chemicals to clean the filter(s). Dry thoroughly before inserting the filter(s) into the unit.
-
Do not add extra length to the exhaust hose by more than a total length of 9′. This will reduce the cooling efficiency of the portable air conditioner.
-
At the end of each season, all water must be drained from the unit, and filter(s) must be cleaned before storage.
-
Only install and operate this appliance as outlined in this instruction manual. At all times, use care when using this appliance.
-
Do not modify this appliance in any way to avoid danger.
Electrical equipment and installations regulated by national legislation must be followed. -
Children must not use this appliance unsupervised.
-
For safety reasons, anyone with psychological, physical, or any medical condition that may impair judgment should only use this appliance when under the supervision of a responsible adult.
-
For safety sake, never use a damaged power cable; always refer to the manufacturer or an authorized technical service center if the appliance requires repair.
-
It is essential that the appliance is connected to an efficient earth system checked by a qualified electrician.
-
The use of extension cables is not recommended.
-
The Air filter should be cleaned a minimum of once every two weeks.
-
Do not place the air conditioner near any heating appliance.
-
The appliance should be transported upright or on its side. Any internal circuit water should be emptied before moving. Do not turn on the appliance for at least one hour before starting it.
-
Flammable substances or pressurized containers (eg aerosol cans) should be kept a minimum of 50cms away.
-
The appliance should not be installed in rooms containing sulfur, gas, or oil.
-
Do not disconnect the appliance by pulling on the power cable; always disconnect the appliance before any cleaning or maintenance is undertaken.
-
Do not store anything on top of the appliance, especially heavy or hot objects.
-
Repairs must only be undertaken by authorized service centers of the manufacturer.
Failure to comply may be dangerous. -
Do not store the appliance covered with plastic bags.
-
Remember the environment when disposing of packaging around the appliance and when the appliance has reached its used by date.
-
A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
-
A warning to keep ventilation openings clear of obstruction.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
-
Children shall not play with the appliance.
-
Cleaning and user maintenance shall not be made by children without supervision.
-
If the power cord on this unit is damaged it must be replaced by the manufacturer, its service agent, or qualified persons in order to avoid a hazard.
-
This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely.
Children should be supervised to ensure that they do not play with the appliance. -
This appliance is intended for domestic use only, any other use may invalidate the warranty and might be dangerous.
-
Do not pierce or burn.
-
Use only implements recommended by the manufacturer for defrosting or cleaning.
-
Do not use the appliance in a room with continuously operating sources of ignition (eg. Open flames, an operating gas appliance, or operating electrical heaters.
-
Do not perforate any of the components in the refrigerant circuit.
-
Refrigerant gas may be odorless.
-
Stagnation of possible leaks of refrigerant gas in unventilated rooms could lead to fire or an explosion hazard should the refrigerant come in contact with electric heaters, stoves, or other sources of ignition.
-
Use care when storing the appliance to prevent mechanical faults.
-
Only persons authorized by an accredited agency certifying their competence to handle refrigerants in compliance with sector legislation should work on refrigerant circuits.
-
Maintenance and repairs requiring the assistance of other qualified personnel must be carried out under the supervision of specialists in the use of inflammable refrigerants.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.
WARNING
Do not use means to accelerate the defrosting process or to clean,other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating
ignition sources (for example open flames, and operating
gas appliance or an operating electric heater.)
Do not pierce or bum.
Be aware that refrigerants may not contain an odor.
NOTE: The manufacturer may provide other suitable examples or may provide
additional information about the refrigerant odor.
Warning: Risk of fire/Flammable materials
DANGER – Risk Of Fire Or Explosion. Flammable Refrigerant
Used. To Be Repaired Only By Trained Service Personnel. Do Not Puncture
Refrigerant Tubing. CAUTION – Risk Of Fire Or
Explosion. Dispose Of Properly In Accordance With Federal Or Local
Regulations. Flammable Refrigerant Used.
OPERATING CONDITION
MODE | ROOM TEMPERATURE |
---|---|
COOL | Higher than 64°F |
DRY | Higher than 60°F |
HEAT | Higher than 45°F |
Your portable air conditioner is supplied with a Leakage-Current
Detection and Interruption (LCDI) plug. This plug reduces the risk of fire due
to arcing faults in the power supply cord. Please follow the instructions
below to ensure that the LCDI plug works properly.
-
Plug the power cord into a grounded wall outlet. Do not plug into a power strip or extension cord.
-
Press the TEST button on the plug. This should trip the plug and cut the power to the air conditioner. If the plug does not
trip and the unit comes on, please contact technical support. -
Press the RESET button to start the air conditioner.
-
Do NOT use the TEST and RESET buttons to turn the air conditioner on and off.
IDENTIFICATION OF ACCESSORIES
Note: Please visit whynter.com for optional accessories information
IMAGE | ACCESSORY NAME | QUANTITY |
---|---|---|
Intake and Exhaust hose | 2 pieces | |
Fixtures | ||
attached to the covers upon unboxing | 2 pieces | |
Screws | 8 pieces | |
Hose connectors | 4 pieces | |
Window slider kit | 1 set | |
Covers | ||
attached to the fixtures upon unboxing | 2 pieces | |
Remote control | 1 piece | |
Optional Intake filter (sold separately) | 1 piece | |
Optional 3M™filter (sold separately) | 1 piece | |
Carbon Filter | 1 piece | |
Storage Cover | 1 piece |
** The fixture pieces may come attached to the cover pieces. To remove, twist the cover pieces to allow the tab from the fixtures to disengage from the covers, and twist the covers to remove from the fixtures.
IDENTIFICATION OF PARTS
Front
1. Air vent
2. Control panel
Rear
3. Evaporator air intake/air filter
4. Air intake hose
5. Air exhaust hose| 6. Casters
7. Drain plug
8. Power cord
---|---
OPERATING YOUR AIR CONDITIONER
Before you begin, thoroughly familiarize yourself with the control panel, remote control, and all of the functions. Follow the symbol for the desired function. The unit can be controlled by the unit control panel alone or with the remote control.
CONTROL PANEL
| Cooling mode
---|---
| Dehumidify mode
| Fan only mode
| Heating mode
| Display set temperature
| Warning light
the machine will stop running
|
Display timer setting of auto switch on/off
| High fan speed
| Med fan speed
| Low fan speed
Power Control
Turns the unit on and off.| Timer
Turns the timer function on and off.
---|---
Warning Light
Condensation water may accumulate in the unit. If the internal reservoir
becomes full, the warning light and the STOP light will come on and the unit
will stop until the water is drained.| Timer/ Temperature Set Control
Adjusts set thermostat temperature and timer.
The displayed temperature is the set temperature.
NOTE: This unit is capable of displaying the set temperatures in Fahrenheit or
in Celsius. To convert from one to the other, press and hold the Up and Down
buttons for 3seconds.
Mode Control
Controls the 4 function modes: COOL, DEHUMIDIFY
FAN and HEAT.
Fan Speed Control
Controls the 3 fan speeds: High, Medium & Low.
NOTE: Unit does not need to be vented in Fan mode
INSTALLATION INSTRUCTIONS
Location
The air conditioner should be placed on a hard and level surface strong enough
to support its weight.
The unit is equipped with caster wheels for portability. It should only be
rolled on smooth, flat surfaces.
Use caution when rolling on carpet surfaces. Do not attempt to roll the unit
over objects.
The air inlet and outlet should be free of any obstructions and be placed with
at least 20″ of clearance for efficient air-conditioning and circulation.
Exhaust hose Installation
When using the air conditioner, the hot air from the exhaust hose must be
exhausted out of the room to complete the air exchange of the condenser. The
intake hose is optional. When the unit is operating in dehumidifying or fan-
only mode, installation of the exhaust hose is optional.
-
Fully expand each end of the exhaust hose about 6”.
-
Install the hose connectors onto the exhaust and intake hoses by threading counterclockwise.
-
Align the tab cut-outs of each of the hose connectors to the tabs on the air exhaust and air intake at the rear of the unit and snap in place.
If installing the optional air intake hose in an area with poor air quality,
we recommend purchasing the intake hose pre-filter accessory.
Only extend the hose to the necessary length, keeping it as short and as
straight as possible.
We do not recommend extending the hose more than 9′ long.
If you are interested in purchasing an additional exhaust hose, please contact
support@whynter.com
for retail sales information or visit
www.whynter.com for a list of optional accessories.
Window kit Installation
The window kit has been designed to fit most standard vertical and horizontal
windows. However, it may be necessary to modify the installation procedures to
accommodate your window.
NOTE:
-
If your window opening is smaller than the minimum length of the window slider kit, the window slider kit can be cut to fit the window opening. Never cut into the exhaust and intake hose cut-outs on the window slider kit.
-
If your window opening is larger than the maximum length of the window slider kit, additional material will be needed to cover the open space such as Plexiglas, PVC plastic, plywood, etc.
Alternately, an additional window slider kit can be purchased to be used in combination with the included kit. -
When using the window slider kit on a window or sliding door, additional security measures may be needed.
-
Open the window approximately 5″.
-
Adjust the length of the window slider to the same length and width of the opening of the window. Cut the window slider if
necessary to fit the length of your window. -
Insert the fixture through the back grooved side of the window slider hose-cutout, aligning the screw holes on the fixture with
the screw holes on the unit. Place the screws in the holes from the front of the window slider kit and tighten. (Fig. 1)
-
Adjust the slider kit to fit your window. The slider kit comes with screws installed on the main window piece. The long and short
extension pieces can be adjusted to fit your window, and the screws can be tightened to keep the extension pieces from sliding. Additional holes can be drilled in the window kit to allow for a further range of adjustment. -
Fit the window slider kit into the window opening and close the window to secure the window slider kit. For long term
installation, you may screw the window kit into your window frame. -
Move the air conditioner close to the window, extend the hose to the necessary length, keeping it as short and as straight as possible and attach the other end of the hose to the window slider kit.
-
Align the tab cut-outs of the hose connector to the tabs on the fixture and snap the hose connector to the window slider kit.
AIR FILTERS INSTALLATION
Your Whynter portable air conditioner is equipped with a washable Pre-Filter
and an Activated Carbon Filter.
The washable Pre-Filter removes large particles such as dust, pet hair, and
dander.
The Activated Carbon filter is designed to remove smoke and other odors. It is
recommended you replace the Activated Carbon filter every 2-3 months or as
needed. Follow the steps below to install the filters.
WARNING: NEVER OPERATE THE AIR CONDITIONER WITHOUT THE PRE-FILTER
-
Pull up the pre-filter frame
-
Remove the Pre-Filter from the filter frame.
-
Place the Activated Carbon filter on the Pre-Filter.
-
Reattach the filter frame.
-
Insert the assembled filter frame into the unit.
An optional 3M™Filter can also be purchased to replace the activated carbon
filter. The3M™
The filter has an agent that helps inhibit the growth of mold and mildew on
the filter. This filter is electrostatically charged for enhanced particle
capture and retention.
If you are interested in purchasing optional accessories, please contact
support@whynter.com for retail sales information.
Note:** The optional 3M™Filter is not washable and should be replaced every
3 months.
OPERATION INSTRUCTIONS
- BEFORE USING YOUR PORTABLE AIR CONDITIONER
- Remove the exterior and interior packaging
- Before connecting the appliance to a power source and operating, let the unit stand upright for a minimum of 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation
SWITCHING ON/OFF THE AIR CONDITIONER
- The unit can be switched ON or OFF by pressing the Power button on the control panel or the Power button on the remote control.
COOLING MODE
- In this mode, the air conditioner cools and dehumidifies the room. To activate the cooling function, press the Mode Control button until the indicator illuminates. When a cooling mode is set, the compressor will start in approximately 3 minutes.
- NOTE: In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the hot air.
- The temperature setting range of this air conditioner is from 61F. To set the temperature, press the+ or – buttons. This air conditioner has a 5°°F to 89F temperature cushion; if the set temperature is within 5°°F of the ambient temperature, the unit runs in fan only mode. This saves energy and prolongs the life of the compressor of the air conditioner. Once the set temperature is achieved, the compressor will turn off and the fan runs continuously to circulate the air within the room.
- To set the fan speed, press the Fan Speed button.
- Note: When the compressor is running, the sound difference between each fan speed is not very noticeable.
DEHUMIDIFYING MODE
-
In this mode, the air conditioner dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to Low.
-
To activate the dehumidifying mode, press the Mode Control button until the a:J indicator illuminates.
When switching between functions, there will be an approximate 3 minute transition time. -
In dehumidifying mode, the exhaust hose does not need to be vented. If the exhaust hose is vented, the room will be cooled as it dehumidifies. To prevent cooling, remove the exhaust hose from the window kit and allow the warm air from the rear to be re-circulated into the room. If the room temperature is higher than 77F, the fan speed is set at Low.°F, the fan speed can be adjusted. If room temperature is lower than 77°
-
Note:
-
When using the dehumidifying mode, venting the exhaust hose to the outside is not required. If vented, the warm air is exhausted to the outside, and cooling within the room may occur. Additionally, if the exhaust hose is not vented, the unit may require more frequent draining.
-
The air conditioner does not have a humidistat in which a specific humidity level can be set.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air
within the room. To activate the fan-only mode, press the Mode Control button
until the indicator illuminates. In this mode, the temperature cannot be set.
Subsequently, set the desired fan speed by pressing the Fan Speed button.
Note: When using the fan-only mode, venting the exhaust hose to the
outside is not required.
HEATING MODE
-
In this mode, the air conditioner heats the room. To activate heating mode, press the Mode
Control button until the RED indicator comes on. When the heating mode is set, the rear fan will start first, followed by the compressor then the air output fan into the room.
Note: The compressor will start in approximately 3-5 minutes and it will take approximately 3-5additional minutes for the heat to blow from the front air output vent. -
The temperature setting range of this air conditioner is from 61°°F to 77F. To set the temperature, press the+ or – buttons. Once the set temperature is achieved, the compressor and the fan will stop.
Note: This unit uses a heat pump for heating and heating mode will not work when the temperature is below45F. -
In heating mode, cold air is exhausted from the outdoor exhaust port and the exhaust hose must
be connected to exhaust the cold air produced by the unit. -
If outside temperature is lower than room temperature, the air intake hose should be removed and the included cover placed onto the air intake fixture. The unit will take in air from the room air filter.
Note: When the compressor is running, the sound difference between each fan speed is not very noticeable.
TIMER (DELAYED SWITCH ON / OFF) FUNCTION
- This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner.
The time (hours) delay can be set, enabled, and disabled. The timer is adjustable between 1-24 hours.
SETTING SWITCH-OFF TIMER
With the air conditioner operating in any function mode, press the Timer
Control button. Then set the desired time delay OFF hours by pressing the + or
– buttons. When the delay time set has elapsed, the air conditioner switches
off.
SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off press the Timer Control button. Then set the
desired time delay ON hours by pressing the + or – buttons. When the delay
time set has elapsed, the air conditioner switches on.
AUTO-RESTART
In the event of a power outage, the air conditioner restarts at the previously
set function mode and settings when power is restored.
NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The
sounds listed below are normal. Noise reflecting off hard surfaces such as a
floor or wall can make the sounds seem louder than they actually are.
- The compressor may make a pulsating or high-pitched sound.
- Water running from the evaporator to the water tank may make a splashing sound.
- Refrigerant flowing may make a gurgling sound.
- Fan sound may come from front and back air vents.
COMPRESSOR LOCKOUT
This portable air conditioner is optimized to operate in an ambient
temperature of 64°°F – 90F. The compressor circuit has an automatic 3 minute
time delayed start if the unit is turned off and on quickly.
WATER DRAINAGE
The air conditioner has the capacity to dehumidify up to 71 pints per day. The
patented self evaporating function of the unit fully exhausts all
condensation automatically in most environments when humidity is less than
70%. In areas with more than 70% humidity, the self-evaporating function can
still exhaust about 98% of the moisture and the remaining 2% of moisture will
be collected in the water tank of the air conditioner. When there is excess
water condensation inside the unit, the air conditioner stops running and the
RED Stoplight illuminates. The Stoplight indicates that the water condensation
needs to be drained manually:
Manual Drainage:
- Turn off the unit.
- Carefully roll the unit to a drain location or position a flat container, dish, or optional drain bucket accessory (sold separately) under the drain area of the lower drain port.
- Remove the drain cover and rubber plug and the condensed water will drain out automatically.
- Once all the condensed water is drained, replace the drain rubber plug and cover into the drain firmly.
Note: Please contact support@whynter.com for retail sales information or visit whynter.com for a list of optional accessories
REMOTE CONTROL
The portable air conditioner can be switched on by the remote control.
NOTE:
- Other appliances in the same room controlled by remote control (TV, radio, stereo, etc.), may cause interferences.
- Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner.
- Remove the batteries if the remote control is not used for long periods.
INSTALLING BATTERIES
- Only use two AAA 1.5V Batteries in the remote control.
- Always change both batteries at the same time.
To insert the batteries, open the flap on the back of the remote control by sliding if off. Strictly adhere to the polarity signs on the bottom of the battery housing, close the flap once the batteries have been inserted.
Notes
– Do not drop the remote control.
– Do not place the remote control in a location exposed to direct sunlight.
– The remote control should be placed about 1 meter or more away from the TV,
or any electrical appliances.
CARE AND MAINTENANCE
IMPORTANT:
- Switch off the air conditioner and disconnect the plug from the power outlet
- Drain al collected condensation from the upper and lower drain ports.
- Only transport the air conditioner in an upright position.
CLEANING THE PRE-FILTER
-
This unit includes two air filters; a washable pre-filter and an activated carbon filter.
-
To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended that the pre-filter is washed at least once every two weeks depending on use.
1. Switch off the air conditioner.
2. Pull the pre-filter frame from the unit.
3. Remove the activated carbon filter from the pre-filter.
4. Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the pre-filter.
5. Rinse the pre-filter thoroughly under warm running water (no hotter than 100F.)
6. Dry thoroughly before re-inserting the filters. -
NOTE: The activated carbon filter and 3M™
Antimicrobial Filter (sold separately) is not washable.
They are optional filters and should be replaced every 2-3 months or as needed if used. -
Please contact support@whynter.com for retail sales information or visit whynter.com for a list of optional accessories
WARNING! Never operate the air conditioner without the pre-filter in place
CLEANING THE AIR CONDITIONER
- Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner.
- Use a soft damp cloth to wipe the body of the unit.
- Never use harsh chemicals, oil-based products, detergents, chemically treated cloths, or other cleaning solutions. These could possibly damage the body of the air conditioner.
END OF SEASON STORAG E
This portable air conditioner comes with one end-of-season storage cover. We
highly recommend that a storage cover bag is utilized when the unit is not
going to be used for a period of time.
WARNING: To avoid the danger of suffocation, keep this bag away from
babies and children.
- Switch off the air conditioner and disconnect the power plug from the power supply outlet before cleaning the air conditioner.
- Clean the pre-filter.
- Drain the condensed water completely.
- On a warm day, set the unit to Fan only mode for half a day to dry the unit internally.
- Gather the power cord and bundle it.
- Remove the batteries from the remote.
- If leaving the window kit in place, disconnect the exhaust and intake hose from the window slider kit and place the included covers on the fixtures. Otherwise, remove the window kit from the window opening. To remove the hose connectors from the fixtures on the window kit, slightly turn, push and gently pull the connector to release.
- Place the storage cover over the air conditioner.
Note: Depending on use, it is recommended that the air conditioner be
cleaned internally annually.
Please contact Whynter at support@whynter.com for
internal maintenance cleaning instructions.
TIPS:
-
Keep the exhaust hose as short and straight as possible
The exhaust hose removes heat from the room. It should remain as short and straight as possible without sharp bends or twists to maximize efficiency. If the exhaust hose must be extended, do not exceed 9′. -
Turn the air conditioner on early
Turning the air conditioner on early instead of waiting until the hottest point of the day will allow the
unit to be more effective. The air conditioner will not have to work as hard to cool the room down and maintain the set temperature. -
Reduce heat sources
Direct sunlight, televisions, computers, and other heat-generating appliances work against the air conditioner by introducing heat into the space.
• Close window curtains and blinds to keep direct sunlight out
• Close doors and windows
• Keep ovens and stoves off
• Turn off unused lights
• Add weather stripping around windows and doors -
Keep the air filter clean
Regular cleaning will help keep your air conditioner working properly. Dusty filters and vents greatly reduce the airflow and efficiency of the unit.
• Clean the washable pre-filter regularly
• Replace the activated carbon filter every 2-3 weeks depending on use
• Vacuum any accumulated dust from around all vents
TECHNICAL DATA
Model: | ARC-14SH |
---|---|
Cooling capacity : | 14,000 BTU (ASHRAE-128 Standard) |
9,200 BTU (DOE+ 2017 Standard) 13,000
Heating capacity :| BTU (ASHRAE-128 Standard) 8,200 BTU
(DOE+ 2017 Standard) 115v/ 60Hz
Power supply :| 1300 Watts Cooling | 1000 Watts Heating
Maximum power input :| 11.6 Amps Cooling | 11.6 Amps Heating
Maximum input :| 71 Pts / Day
Dehumidifying capacity :| 61 ° F to 89° F
Thermostat: Refrigerant :| R32/16.5oz(468g)
Airflow (max.) :| 430 m3/ Hour
Fan speeds :| 3 (H, M, L)
Unit Dimensions :| 19″ W x 16″ D x 35.5″ H
Unit Weight :| 76 Ibs
Exhaust/ Intake Hose:| 5.9″ diameter
Hose Connectors:| 5.9″ diameter with 5.0″ diameter reducer
Fixture and Window Kit:| 5.0″ diameter
Window Kit:| 6.5″ W x 20″ (min)/ 46″ (max) L
TROUBLESHOOTING
Problem
| Possible Causes|
Solutions
---|---|---
The portable air
conditioner does not turn on| ·Power failure/outage.
·The automatic switch, line fuse, or breaker has been tripped.
·The power supply voltage is too low.
·The power cord is damaged.
· The L.C.D.1. power plug for the unit is tripped.
·The internal water reservoir is full.
·Possible loose connection
·Internal fuse has blown| ·Restore the power supply.
·Flip the switch / change the fuse / turn the breaker back on. Also note that
you may have too many appliances drawing power on one circuit, you may need to
move the other appliances to another circuit.
·Move the unit onto another circuit with the correct voltage.
·Contact Whynter Service Department. Only authorized personnel should replace
the damaged power cord or power plug.
· Press the Reset button on the L.C.D.1. power plug.
· Drain water from the air conditioner.
· Contact Whynter Service Department
The unit turns on but the compressor does not turn on (the fan runs but the
unit is not cooling)| ·The room temperature is outside of the operational
tolerances of the unit.
·The Cooling mode is not on.
·The compressor has not turned on yet because of its time delay.
·The set temperature is too high.
·The internal water reservoir is full.| · This unit is designed to work in
ambient temperatures of 64°F to 95°F.
·Press the MODE button until the COOL light is shown on the display.
·Give the compressor 3 minutes to turn on after the Cooling mode has been
selected.
·Set the air conditioner to a lower temperature. It is recommended to set the
temperature to at least 5°F of the ambient temperature.
·Either manually drains the water by removing the drain plug or allow the unit
to exhaust the water itself by running the fan-only mode. Then cooling will
resume.
The air coming out of the unit is not very cold, or the airflow volume is
weak| ·The filters are dirty or obstructed.
·The air intake or exhaust is obstructed.
·The unit is set in DRY or FAN mode.
·The unit is set to low fan speed.| ·Clean the air filters.
·Make sure there is at least 20″ of clearance from the air intake. Make the
length of the exhaust hose is as short as possible.
·Set the unit to the cooling mode.
·Set the unit to a higher fan speed.
The unit has worked for a long time, but the room is not cold enough| .
Windows or doors are open.
·There are too many people in the room.
· There is direct sunshine into the room.
·The room is a kitchen or with many heat-producing appliances
·There is a server in the room.
· The room is too large.| ·Close all windows and doors.
·You may need additional cooling or another air conditioner.
·Close curtains or blinds and try to minimize the amount of direct sunlight
into the room.
·You may need additional cooling or another air conditioner.
·You may need additional cooling or another air conditioner.
·You may need additional cooling or another air conditioner.
---|---|---
The unit is very noisy| · The unit is not level.
· The surface underneath the unit is uneven.
·Low power voltage.| ·Make sure the unit is on hard, level, and stable
surface.
·Move the unit to a location with a level and hard floor.
·Make sure the wall outlet and support the required power consumption of the
air conditioner and does not use an extension cord.
The unit leaks water| ·The unit is tilted or not leveled
· The water tank is full.| ·Make use of the unit is leveled.
·Drain water from the drain plug at the back of the air conditioner.
The unit needs to be drained too often| ·The humidity in the area may be very
high
·Possible loose connection| ·Remove the intake hose if the outside humidity is
high or it is raining
·Contact Whynter Service Department
Fan speed cannot be changed| ·Fan speed differences are not very noticeable|
·The fan speed difference is not very noticeable when the compressor is on.
Try setting the unit to Fan only mode, you should be able to hear the
difference between high and low fan speed settings.
The unit does not heat| · The room temperature is too low.
·The heating mode is not on.
·The compressor has not
turned on yet because of its time delay.
·The set temperature is too low.
·The internal water reservoir is full.
·The humidity in the area may be very high
·There may be a loose connection| ·The heat pump of the air conditioner does
not operate when the temperature is below 45F.
·Press the MODE button until the HEAT light is shown on the display
·Give the compressor 3 minutes to turn on after the Heating mode has been
selected.
·Set the air conditioner to a higher temperature. It is recommended to set the
temperature to at least 5F of the ambient temperature.
· Either manually drains the water by removing the drain plug or allow the
unit to exhaust the water itself by running the fan-only mode. The cooling
will resume.
·Remove the intake hose if the outside humidity is high or it is raining
·Contact Whynter Service Department
ONE YEAR LIMITED WARRANTY & THREE YEAR WARRANTY ON COMPRESSOR
This WHYNTER product is warranted to the original owner, purchased from an
authorized Whynter dealer within the 48 U.S. continental states, for one year
from the original purchase date against defects in material and workmanship
under normal residential usage. Should your WHYNTER product prove defective
within one year from the date of purchase, contact Whynter’s Customer Support
team with the serial number and proof of purchase to make a warranty claim. A
Return Authorization number must be issued before returning any parts or
products. Parts or products received without a Whynter issued Return
Authorization number will be refused. Under this warranty, Whynter will repair
or replace any parts found defective with new or remanufactured parts or
exchange the defective product with a new, refurbished, or remanufactured
product at our discretion. All defective products and parts covered by this
warranty will be repaired or replaced on a mail-in basis to Whynter’s Service
Center. This warranty is not transferable. After the expiration of the
warranty, the cost of labor and parts will be the responsibility of the
original owner.
The compressor of portable air conditioners is warranted for an additional two
years after the one-year limited warranty
expires from the date of purchase.
Return freight is prepaid by Whynter within two months of purchase. After two
months to one year, the customer will be responsible for the return freight
cost to Whynter’s Service Center. Please package the product carefully in its
original packaging to avoid damage in transit. Whynter is not responsible for
damage resulting from shipper mishandling or improper packaging. Please retain
the original box and packaging materials.
THIS WARRANTY DOES NOT COVER:
- Acts of God, such as fire, flood, hurricanes, earthquakes, and tornadoes.
- Improper power supply such as power surge, low voltage, defective household wiring, or inadequate fuses.
- Use in commercial or industrial applications.
- Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a defect in material or workmanship.
- Damage caused by consumer misuse, tampering, lack of maintenance, or failure to follow the care and special handling provisions in the instructions.
- Damage to the finish of the case, or other appearance parts caused by wear.
- Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.
- Removal, Replacement Packaging, Freight, and Insurance cost for the warranty service.
- Products sold AS IS or from an unauthorized reseller.
- Products that have had their serial numbers removed or defaced.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE
PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED
WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY
LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL
OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES
RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED
WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF
IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.
THIS WRITTEN WARRANTY
GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM
STATE TO STATE.
The warranty, product contents, and specifications are subject to change at
any time without notice; please refer to
www.whynter.com for the most current information.
Please retain the original proof of purchase.
To register your warranty, please visit
www.whynter.com and fill out the online
Warranty Registration form. Please be sure to include a copy of your purchase
invoice.
To obtain service or information, contact Whynter LLC via email at
support@whynter.com or call 866-WHYNTER
(866-949-6837).
Copyright © 2020 Whynter LLC
www.whynter.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>