Halco CLW08C LED HID Retrofit Lamp User Manual

June 6, 2024
Halco

Halco CLW08C LED HID Retrofit Lamp logo

Halco CLW08C LED HID Retrofit Lamp

Halco CLW08C LED HID Retrofit Lamp
prod

Can not use the electric generator to test the LED lamp. Please avoid using the led fixture in environments where there is smoke, sulfur, and corrosive substances. If used in such an environment, make sure the led fixture is well protected by an enclosed lampshade whose dimension is no less than below size, and whose material is either glass or semi-glass, semi-metallic. The surface of the lampshade shall not have any covering which prevents heat dissipation.

LED HID Retrofit Lamp Instructions

Product features

  • 12W -120W Wattage Options.
  • 3 CCT Selectable 3000K / 4000K / 5000K.
  • 36W -120W Wattage selectable (Ships at the highest output which is in the ordering logic).
  • Lumen output from 1680 to 18600 (SOW to 400W Replacement).
  • LineConnect Type B Wiring with AC 100-277V.
  • Motion Sensor option available on BOW, 100W, and 120W lamps.
  • Clear Durable Polycarbonate lens.
  • Aluminum housing with efficient heat sink design for heat dissipation.

Application

Halco CLW08C LED HID Retrofit Lamp
fig1

Supermarket, warehouse, garage, home, office, hotel, hospital, school, street, garden and many more.

Installation Instructions

Warning: Please make sure the power is off before installation

Halco CLW08C LED HID Retrofit Lamp fig2 Halco
CLW08C LED HID Retrofit Lamp fig3

  1.  Turn off the power switch.
  2. Screw off the CFL, MHL, HPS or another existing lamp.
  3. Disconnect ballast before installing LED HID Retrofit which has an AC Internal driver.Halco CLW08C LED HID Retrofit Lamp fig4 Halco CLW08C LED HID Retrofit Lamp fig5
  4. Wireline voltage as shown in Figures 1 & 2.
  5. Adjust lamp CCT and/or dimming by removing the top plastic cover with a tool or screwdriver. (See figure 3 and CCT adjustable, wattage selectable mode diagram on page 4).
  6. LF Security rope is provided, fix the rope to the lamp using the hook. Then, attach the other end to the luminaire. (See figure 5).
  7. Screw the LED HID Retrofit lamp into the socket (Figure 6-9).
  8. Turn on Power.

CCT adjustable and wattage selectable mode diagram: Wattage selection options

Halco CLW08C LED HID Retrofit Lamp fig5

installation of motion sensor or PIR sensor

To install a motion sensor, remove top plastic cover with a tool or screwdriver as shown below. Once you have CCT and wattage selected, install the motion sensor as shown in Figure 3 and tighten. Use the remote control to commission (one remote needed per job.)

Note: the motion sensor has no dialing code, and remote control is needed for adjustment. Please refer to the instruction for remote control adjustment.Halco CLW08C LED HID Retrofit Lamp fig6

MIN. LAMP COMPARTMENT DIMENSIONS(L x W x H)

Model Number

| Minimum Lamp Compartment Dimension(m m)( H) x(L) x(W)
---|---

HID12-CS-E26-LED

|

300 X 180 X 180

HID18-CS-E26-LED

|

320 X 190 X 190

HID27-CS-E26-LED

|

340 X 200 X 200

HID36-CS-E26-LED HID36-CS-EX39-LED|

380 X 200 X 200

HID45-CS-E26-LED HID45-CS-EX39-LED|

420 X 210 X 210

HID54-CS-E26-LED HID54-CS-EX39-LED|

420 X 210 X 210

HID80-CS-EX39-LED

|

420 X 230 X 230

HID100-CS-EX39-LED

|

440 X 240 X 240

HID1 20-CS-EX39-LED

|

440 X 260 X 260

WARNING

WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaries’ electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS. SUITABLE FOR DAMP LOCATIONS. ADDED WEIGHT OF THE DEVICE MAY CAUSE INSTABILITY OF
A FREE-STANDING PORTABLE LUMINAIRE. USE ONLY WITH A PORTABLE TABLE LAMP THAT IS PROVIDED WITH A SHADE. USE IN PORTABLE TABLE LAMPS IN WHICH THE DISTANCE FROM THE BOTTOM OF THE BASE TO THE TOP OF THE LAMP HOLDER DOES NOT EXCEED THREE (3) TIMES THE MINIMUM BASE DIAMETER. THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS” or “NOT FOR EMERGENCY LIGHTING.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>