Spellman MXP8PN24 High Performance Low Ripple Power Supply User Guide

June 6, 2024
spellman

Spellman MXP8PN24 High Performance Low Ripple Power Supply User Guide

SAFETY

DANGER
HIGH VOLTAGE
RISK OF ELECTROCUTION

Observe extreme caution when working with this equipment

  • High voltage power supplies must always be connected to protective earth
  • Do not touch connections unless equipment is turned off and the capacitance of both the load and power supply are grounded
  • Allow adequate time for discharge of internal capacitance of the power supply
  • Do not ground yourself or work under wet or damp conditions.

Servicing Safety

  • Maintenance may require removing the Instrument cover with the power on
  • Servicing should only be done by qualified personnel aware of the hazards
  • Return to supplier for servicing

Unit Description

Spellman’s MX8 Plus is a well-regulated high performance fast reversible supply featuring a 25ms “hot switchable” polarity reversing capability. This unit consist of one chassis containing the HV output and control circuits for building into the final system.

The current return paths are to the chassis, which is grounded to the system earth by fixings.

Control and monitoring is via a hard-wired interface connector.

Unit Ratings

Power Input

  • Voltage: 24 Vdc ± 10%
  • Current: <500mA nominal continuous
    <1200mA peak during reversing

HV Output

  • Voltage: ± 8 kVdc
  • Current: 100µA maximum
Environmental conditions
  • Operating Temperature : 5°C to +45°C
  • Storage Temperature : -35°C to +85°C. A conditioning period of three hours minimum is required after exposure to Storage Temperatures.
  • Humidity: 0% to 80% RH (non-condensing)
  • Altitude: 2000m ASL at full power

Safety

The HV outputs of the unit are hazardous and the conditions of this manual must be complied with to maintain safety. Operating the unit in a manner not specified in this manual may impair the protection against electric shock provided by the unit.

The unit is contained in an earthed case. The unit shall be properly bonded to the main protective earth termination in the end product via the case.

The unit has been evaluated for use in a Pollution Degree 2, Installation Category II environment.

Consideration should be given to conducting the following tests with the unit installed in the end product:

  • Dielectric Voltage Withstand Test, between live parts of the unit and the end product chassis.
  • Permissible Limits Tests with the unit installed in the end product.
  • Temperatures on power electronic components, transformer windings and accessible surfaces.

Meaning of Symbols

Symbols 

Unit Grounding

The unit is contained in an earthed case. The case of the unit shall be properly bonded to the main protective earth termination in the end product.

Installing the Unit

Initial Inspection

Inspect the package exterior for evidence of damage due to handling in transit. Notify the carrier and Spellman immediately if damage is evident. Do not destroy or remove any of the packing material used in a damaged shipment.

After unpacking, inspect the panel and chassis for visible damage.

Note: Failure to comply with the above could compromise the safe operation of the unit and invalidate the warranty

Electrical Installation

The unit is designed for indoor use and is to be supplied from a double insulated, UL recognized, 24V dc supply.

The units must be terminated safely before operation. Hazardous voltages will be exposed if the connector is removed whilst the unit is enabled.

The unit must be switched off for at least one minute before disconnecting any of the connectors.

The unit shall be properly bonded to the main protective earthing termination in the end product using the bolt down point.

The input and output connectors are not intended for field connections and should only be connected to internal wiring in the end use equipment.

The unit is intended for use as a component and no surface of the unit should be accessible in the end product.

The unit is contained in an enclosed case and can be mounted in any orientation. A cooling air flow is recommended.

Connections and Unit Operation

Input / Output Molex Mini-Fit Jr connector

pin# Signal I/O Description
1 +24VDC I DC in
2 +24VDC Return I Ground return for DC in
3 Enable I enable/inhibit input. TTL high is enabled, TTL low is disabled*
4 Vmon O output voltage monitor. 0 to +8V for OV to ±8kV output (accuracy

±1% of max output, always positive) Output impedance 10k0
5| Vprog| I| voltage control input. 0 to +8V for OV to ±8kV output (accuracy ±1% of max output, always positive)
6| lmon| O| current monitor output. 0 – 10V for OA to 100pA (accuracy ±2% of max output, always positive). Output impedance 10k0.
7| Iprog| I| current control input. 0 to +10V for OA to 100pA (accuracy ±1% of max output, always positive)
8| Polarity control| I| polarity control input. TTL high is positive, TTL low is negative*
9| Analog Ground| –| analogue ground
10| V/I Indicator| O| current/voltage control indicator. TTL compatible output (3.3V max). TTL high when in current mode. TTL low when in voltage mode. Output impedance 1k0.
11-14| | | Pins not used

Note: TTL input. The threshold is set to 1.65V for use with 3.3V or 5V input levels although the input will tolerate up to 15V being applied.

Receptacle: Molex Mini-Fit Jr., Dual Row, 14 Circuits. Series: 5557 Part number : 39-01-2140 Mating connector is not provided.

Please see Molex product page for range of mating connectors (for example Molex part number 39- 01-2141) and crimps (for example Molex part number 39-00-0040): (https://www.molex.com/molex/products/part detail/crimp_housings/0039012140)

Cable: FS cables 12 core braid screen 7-2-12C Part number: 39300212 Length: 508 mm

Receptacle pinout:

Receptacle pinout

HV Output Connector

Manufacturer: Alden
Series: F-SERIES
Part number: F303RX

HV Output Connector

Mating connector is not provided.

Please see Amphenol Alden High Voltage Catalogue for range of mating cables (from Catalogue: all F Series plug will mate with the F303RX receptacle) for example F602RX”L”. https://www.amphenolalden.com/products-solutions /technical-resources

The mating cables are not shielded so the load return must be provided through adequate low impedance and shortest possible connection to the power supply chassis.

Mechanical Installation

The unit shall be fixed in place in the end user system using screws on the hold down points provided.
The units should only be used in a Pollution Degree 2 Installation Category II environment.

The units are intended for use as a component and no surface of the unit should be accessible in the end product.

Unit weight: 1.1 kg
Mechanical Dimensions – see drawing in Appendix A

Appendix A – Mechanical layout

Mechanical layout

Tel : +44 (0)1798 877000
[email protected]