Xi An Aerospace Automation ASAM-RFUH-EIC01 Edge Intelligent Controller User Manual
- June 6, 2024
- Xi An Aerospace Automation
Table of Contents
Xi An Aerospace
Automation ASAM-RFUH-EIC01 Edge Intelligent Controller
User Manual
Edge Intelligent Controller
ASAM-RFUH-EIC01
Xi’an Aerospace Automation Co., Ltd
Summary
The ASAM-RFUH-EIC01 Edge Intelligent Controller is a high-performance, wide- band, and scalable UHF RFID device that complies with the EPC global C1 Gen2 / ISO 18000-6C protocol standard. The device has edge computing capability, possesses the strong capability of single and multi-tag reading, RF output power is adjustable, the device supports RS232, RS485, Ethernet, and other communication interfaces, and it possesses multi-features such as relay output control, optocoupler input, power indication, read status indicator.
Application
The ASAM-RFUH-EIC01 Edge Intelligent Controller can be used in production process control, vehicle management, logistics management, warehouse management, access control and many other applications.
Product characteristics
- Agreement: Electronic tags conforming to EPC-CLASS1-G2 (ISO18000-6C) ISO18000-6B standards.
- Working frequency 902-928MHz/865-868MHz (adjustable according to different countries or regions)
- Supporting dynamic parameter adjustment (e.g. power adjustment, frequency adjustment, etc.)
- Supporting digital input/output control interface, directly expanding other equipment
- Read distance up to 10 meters (related to tag and RF output power)
- Antenna number1-8 external antennas
- Supporting Standard Ethernet Port Communication and Serial Port Communication
- Supporting multiple working modes (active mode, answer mode)
- Working in a broad-spectrum frequency hopping (FHSS) or fixed-frequency transmission mode
- Easily install and debug with special UHF configuration software
- Protection level: IP54.
Technical parameter
- Type: ASAM-RFUH-EIC01
- Transmission frequency: 902MHz-928MHz, 865-868MHz.
- Complying with EPC global UHF Class1 Gen2/ISO18000-6C standard
- Read-write distance: The maximum reading distance can be up to 10 meters. (related to antenna setting)
- Antenna number: 1-8 external antennas 8- channel relay control output, 8-channel optocoupler input function
- Communication interface: RS-232, RS-485, 10/100M
- Ethernet Power supply: AC100V-240V,50-60Hz, power supply
- Multi-label/batch function
- Support Working temperature:-20°C ~ +70°C
- Storage temperature: -30°C ~ +75°C
- Working humidity: 5 %~ 95% RH, no condensation
- Protection level: IP54
- Structure size: 330mm×240mm×53mm
Port and Size
- Terminals: Including 8 relay output control interfaces, 8 optocoupler input interfaces, RS485 interface.
- RS232 interface
- Reset button
- Read status indicator
- Output power interface
- Ethernet interfaces
- External antenna interface
- External antenna interface
- External antenna interface
- External antenna interface
- External antenna interface
- External antenna interface
- External antenna interface
- External antenna interface
- Input power interface
- Trademark
- Mounting holes
Packing list
Category | Number | Remarks |
---|---|---|
ASAM-RFUH-EIC01 | 1 | Main Engine |
Network Cable | 1 | Network Cable Length 1.5m |
RS232 Serial Cable | 1 | Serial Cable Length 1.5m |
AC100V-240V Power Cable | 1 | Power Cable Length 1.5m |
Optional Accessories
category | number | Remarks |
---|---|---|
DI/DO cable | 1 | Optional length of DI/DO cable: |
1.5m/3m/5m
RF cable| 1-3| Optional length RF cable: 3m/5m/9m
ASAM-RFUH-TX01| 1-8| High performance 8dB (circular
polarized antenna)
RS232 Serial Cable| 1| Serial Cable Length 1.5m
- The product is limited to end-user installation.
- End-user does not remove or install the product.
- The product is used for Fixed Applications.
- The product is professionally installed installer will be responsible for ensuring that the proper antenna is employed.
FCC Caution
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance 20cm between the radiator and your body. This transmitter
must not be co-located or operating in conjunction with any other antenna or
transmitter.