HTZSAFE MFR+T001Q3 Wireless Driveway Alarm System User Manual

June 6, 2024
HTZSAFE

HTZSAFE MFR+T001Q3 Wireless Driveway Alarm System

Configuration List

Alarm Receiver 1 piece (includes 1 set installation accessories)

Solar&Wireless Photoelectric

Beam Sensor

| 1 pairs (includes 1 set installation accessories)
English Manual| 1 piece

Note: The alarm system has been programmed already,please operate the system according to the part 3 of the manual;
If you want to add additional beam sensor to the system or connect our system to other alarm system,please operate the system according to the part 4 of the manual or contact us directly;
After-sale Service: E-mail:contact@saferhomee.com

System Components And Usage

HTZSAFE MFR+T001Q3 -Wireless- Driveway-
Alarm -System -FIG 2

Power: Power indicator(will be red if powered on)
Reminder beep: The indicator of “Reminder beep” will be red if you press the “Beep” button once(the alarm receiver has a bleep reminder every 3 minutes if the detector was triggered)
Zone1-Zone4: Total 4 wireless zones(each zone has special alarm tone) Select: Used to select zone number and connect the detector to the alarm receiver
Delete : Used to delete the detectors of the alarm receiver
Pause: Used to enable the “disarming” function(will not alarm if the detectors be triggered)
Beep: Used to enable or disable the “Reminder beep” functionHTZSAFE
MFR+T001Q3 -Wireless- Driveway- Alarm -System -FIG 3

ON/OFF: power switch(turn on/off the alarm receiver)
POWER : power jack(DC12V-15V)
VOLUME : adjust the alarm volume of the alarm receiver HTZSAFE
MFR+T001Q3 -Wireless- Driveway- Alarm -System -FIG 4

14V DC: used to connect extra siren CH1-CH4: relay outputs(normally open or normally close optional); used to connect to other alarm system(CH1-CH4 corresponding to Zone1-Zone4;relay output rating is DC24V or exchange
120V2A current)

Solar & Wireless Photoelectric Beam Sensor HTZSAFE MFR+T001Q3
-Wireless- Driveway- Alarm -System -FIG 5

Horizontal Pipe: easy to know the beams be installed vertically Infrared Beam: used to detect the intruder
Calibration Hole: easy to align with another beam sensor if the beams apart far away
Solar Panel : charge the battery of the beam sensor even in cloudy or rainy days
LCD Display: easy to know how well the beam sensor be aligned with each other
ON/OFF: turn on/off the solar beam sensor
Charge Jack: pull out the red plug to charge the solar beam sensor by DC5V-12V power adapter if the battery of the beam sensor go flat Screw Hole: used to fix the installation accessories

Operation Instructions

Step 1
Charge the solar beam sensors before use

Method 1 : charge the solar beam sensors by the sunlight for a whole dayHTZSAFE MFR+T001Q3 -Wireless- Driveway- Alarm -System -FIG
7

Method 2 : pull out the red plug to charge the solar beam sensors for 4 hours by the DC5V-12Vpower adapter(the power adapter of the alarm receiver is available)please insert the red plug back to the charge jack after charging. HTZSAFE MFR+T001Q3 -Wireless- Driveway- Alarm -System -FIG
8

Step2:
Turn on the Solar&Wireless Photoelectric Beams:
Press the ON/OFF button 3 times(Both the transmitter and receiver)HTZSAFE
MFR+T001Q3 -Wireless- Driveway- Alarm -System -FIG 9
(more than 3 short beeps mean the built-in batteries of the sensor have enough power)

Step 3
Make sure the beams aligned with each other

(bleep prompt and LCD display more than “100” means the beam sensors work properly,
Please note: “100” is a reference value, different weather will get different value
and bigger value means better alignment)

Step 4
Power on the alarm receiver by the power adapter and turn on the alarm receiver

Step 5
Trigger The Solar&Wireless Photoelectric Beam Sensor (Completely block all the 3 infrared beams by thick materials,such as books)HTZSAFE MFR+T001Q3
-Wireless- Driveway- Alarm -System -FIG 12

LCD display “000” means the beam sensor be triggered and alarm receiver alarms–Zone 4 light up)

**Installations

HTZSAFE MFR+T001Q3 -Wireless- Driveway- Alarm -System
-FIG 13**

Solar&Wireless Photoelectric Beam Sensor s1 It installation method HTZSAFE
MFR+T001Q3 -Wireless- Driveway- Alarm -System -FIG 14

Calibration

  1. Place the beam sensor on the same height.

  2. Ensure the beam sensor is vertical (the bubble of the horizontal pipe should be in the middle).

  3. Adjust the direction of the beam sensor to make them align with each other.
    Calibration Hole:used to find another device.
    LCD Display:used to know how well the beam sensor be aligned with each other (the LCD Display will shut down in an hour).

  4. sensors work properly,Please note: “100” is a reference value, different weather will get different value and bigger value means better alignment

  5. Tighten the screws to ensure the position and direction will not be moved easily.

Installation method(with iron brackets)
Please note:the package not includes the iron bracketsHTZSAFE MFR+T001Q3
-Wireless- Driveway- Alarm -System -FIG 14

  1. Place the beam sensor on the same height.

  2. Ensure the beam sensor is vertical (the bubble of the horizontal pipe should be in the middle).

  3.  Adjust the direction of the beam sensor to make them align with each other.
    Calibration Hole:used to find another device.
    LCD Display:used to know how well the beam sensor be aligned with each other (the LCD Display will shut down in an hour).

  4. sensors work properly,Please note: “100” is a reference value, different weather will get different value and bigger value means better alignment

  5. Tighten the screws to ensure the position and direction will not be moved easily.

Step 7
Test and verify the alignment
Block the infrared beams by thick materials(such as books)

  1. Block only top 2 beams—No Alarm
  2. Block only bottom 2 beams—No Alarm
  3. Block all 3 beams—Alarm
    The same way to test and verify another sensor

Other Settings

How to add/delete detectors to the receiver ADD

Step 1
Power on the alarm receiver and turn on the alarm receiver
Step 2
long time press the “Select” button and release the button when the “Zone” indicator light up(for example,
we selected the zone 2) ;
total 4 zones,and the “Zone” indicator will light up one
by one if you long time press the “select” button;HTZSAFE MFR+T001Q3
-Wireless- Driveway- Alarm -System -FIG 19

Step 3
Trigger the detector(for example,trigger the solar&wireless photoelectric beam sensor)

The indicator light of the the selected zone will blink and bleep prompt(that means the operation was successful)

Step 4
Long time press the “select” button and release the button when the“ Power”indicator light up

Step 5
Trigger the detector again to verify that the detector has been added to the receiver
DELETE
Step 1: Power on the alarm receiver and turn on the alarm receiver

Step 2: long time press the “Select” button and release the button when the “Zone” indicator
light up(which zone the detector will be deleted) ; total 4 zones, and the “Zone” indicator will light up one by one if you long time press the “select” button;
Step 3: Long time press the “Delete” button
Step 4: The indicator light of the the selected zone will blink (that means the operation was successful)
Step 5: Long time press the “select” button and release the button when the“ Power” indicator light up

How to enable or disable the “disarming” function

  • Enable
    Power on the alarm receiver and turn on the alarm receiver Long time press the “Pause” button and release the button when the “Power” indicator light blink(the alarm receiver will not alarm for 5 minutes even if the detector be triggered) ;

  • Disable
    Long time press the “Pause” button and release the button when the “Power” indicator light not blink Or the receiver will disable the “disarming“ function automatically after 5 minutes(3)How to enable or disable the reminder beep function

  • Enable
    Power on the alarm receiver and turn on the alarm receiver Press the “Beep” button once,and the “Reminder Beep” indicator light up means the operation was successful.(the alarm receiver has a bleep reminder every 3 minutes if the detector was triggered)

  • Disable
    Press the “Beep” button once again,and the “Reminder Beep” indicator light turned off means the operation was successful. (4)The output interface wiring method(Normally Close or Normally Open optional)

  1. press the corresponding button on the end. (Figure 1)
  2. .insert the cables to the interface. (Figure 2).HTZSAFE MFR+T001Q3 -Wireless- Driveway- Alarm -System -FIG 22

How to program the sensitivity of the solar beams

The sensitivity of the solar beams divided into 2 types: 200ms (factory default) and 100ms Please follow up the operation steps if you want to switch the sensitivity of the beams to be 100ms
Step 1: Turn on the solar beams by press the ON/OFF button 3 times (both the transmitter and receiver)
Step 2: Long time press the ON/OFF button for 10 seconds and release the button when you hear bleep prompt,and then press the ON/OFF button 6 times quickly(operate the transmitter first,and then operate the receiver)Note:if switch the sensitivity of the beams back to factory default (200ms),press the ON/OFF button 5 times
Step 3: Make sure the solar beams aligned with each other
Step 4: Long time press the ON/OFF button for 10 seconds and release the button when you hear bleep prompt(only the receiver)
Step 5 : Press the ON/OFF button 4 times(only the receiver)
Step 6: Program successfully when you heard 6 times bleep prompt

Technical Parameters

Technical parameters

Item Technical Parameters
Working Voltage DC12- 15V
Working Current Static Current 20mA;Alarming Current 180mA
Wireless Frequency 433MHz FSK+FHSS
DC14V Output Current Maximum 400mA
Relay Output Rating DC24V/ AC120V at 2A

Solar &Wireless Photoelectric Beam SensorHTZSAFE MFR+T001Q3 -Wireless-
Driveway- Alarm -System -FIG 24

Item Technical Parameters
Infrared Detection Range 100m(300 feet)
Wireless Transmission Range 1KM(3000 feet)
Beam Quantity 3
Wireless Frequency 433MHz FSK+FHSS
Maximum Trigger Number In 24 Hours ≤200 times
Working Voltage 3.3V
Battery Type Chargeable LiFePO4 Battery
Battery Capacity Transmitter:500mAh,Receiver:500mAh
Static working Current ≤0.5mA
Infrared Wavelength 940nm±20nm
Solar Panel Output Current 1800Lux illumination levl: ≥2mA

(Remarks:The outdoor illumination intensity on rainy days is about 2000Lux)

Working Temperature Range| -30℃~70℃

After-sale Service:
E-mail:contact@saferhomee.com

Read User Manual Online (PDF format)