OFITE 171-49 Single Unit 115 Volt Temperature Control Unit Instruction Manual
- June 5, 2024
- OFITE
Table of Contents
171-49 Single Unit 115 Volt Temperature Control Unit
Instruction Manual #171-49: Single Unit, 115 Volt
171-49-4: Four Unit, 115 Volt
OFI Testing Equipment, Inc.
11302 Steeplecrest Dr. · Houston, Texas · 77065 · U.S.A.
Tele: 832.320.7300 · Fax: 713.880.9886 · www.ofite.com
© Copyright OFITE 2013
Intro
The OFITE Temperature Control Unit is a convenient tool for precisely
controlling the temperature of an electrical heating device. Simply plug the
heating device into the Temperature Control Unit and the built-in Eurotherm
2123 controller will regulate the power output to the heater.
The controller can be set with either a simple temperature setpoint or an
advanced timer.
The Temperature Control Unit is ideal for use with thermocouples, hot plates,
and heating jackets for filter presses.
Components
120-70-1-003| Fuse Holder
---|---
130-76-03| Thermocouple
#152-37| Power Cord
174-03| Electronic Controller, Eurotherm Model 2132
172-09| Fuse, 10 Amp, Box of 5
Specifications
- Maximum Temperature: 450°F (232.2°C)
- Maximum Power: 10 amps
- Temperature Controller: Eurotherm 2132 – Detailed instructions available from Eurotherm: http://www.eurotherm.com/support/manuals/2132.htm
Photos
Operation
| 1. Plug the Temperature Control Unit into an appropriate power source. The
power inlet is on the back of the unit.
The four-unit model (#171-49-4) has two power inlets on the back. The one on
the left provides power to units 3 and 4. The one on the right provides power
to units 1 and 2.
---|---
| 2. Plug the heating device into the Temperature Control Unit. The unit has
a power outlet on the front and one on the back.
Do not use both power outlets at the same time. Doing this could cause the
unit to draw too much power and blow the fuse.
| 3. Plug the thermocouple into the thermocouple port. The unit has a
thermocouple port on the front and one on the back.
Do not use both thermocouple ports at the same time. Doing this could result
in incorrect readings.
| 4. Turn the “Main” power switch on. The Eurotherm controller will run
through a short series of self-tests. At the end of the tests, the display
will show the current ambient temperature. This is the home screen.
The four-unit model has two “Main” power switches. The one on the left
controls units 1 and 2. The one on the right controls units 3 and 4.
| 5. Use the “Up” and “Down” arrows to select a temperature setpoint. The
“OP1” light in the upper left-hand corner of the display will illuminate when
the controller is sending power to the heating device.
| 6. Turn the “Heat” switch on.
The “Heat” switch controls power to the power outlet. If the “Heat” switch is
off, the heating device will not receive any power from the Temperature
Control Unit, regardless of the reading on the display.
Timer
-
Use the “Up” and “Down” arrows to select a temperature setpoint.
-
Press the “Page” button until the display reads “SP”.
-
Press the “Scroll” button until the display reads “tm.OP”.
-
Use the “Up” and “Down” arrows to select one of the five-timer programs:
Opt. 1 – The controller will engage the heater up to the temperature setpoint before the timer starts. When the timer times out, the controller will turn off the heater. The display will flash “END” to signal that the timed program is complete.
Opt. 2 – The controller will engage the heater up to the temperature setpoint before the timer starts. When the timer times out, the display will flash “END” and leave the heat on indefinitely.
Opt. 3 – The controller will engage the heater up to the temperature setpoint while the timer is running. When the timer times out, the controller will turn off the heater. The display will flash “END” to signal that the timed program is complete.
Opt. 4 – The controller will engage the heater up to the temperature setpoint while the timer is running. When the timer times out, the display will flash “END” and leave the heat on indefinitely.
Opt. 5 – The controller will engage the heater up to the temperature setpoint after the timer times out. The heater will remain on indefinitely and the controller will return to normal operation. -
Press the “Scroll” button until the display reads “tmr”. Use the “Up” and “Down” arrows to set the time (in minutes) that you want the timer program to run.
-
Press the “Page” and “Scroll” buttons simultaneously to return to the home screen. The timer program will now begin to run.
-
When the timer times out, the controller with entering standby mode (unless Opt. 5 is used).
a. If the display is flashing “End”, press the “Page” and “Scroll” buttons simultaneously to return to the home screen.
b. If the “MAN” light is on, press the “Scroll” button until the display reads “M-A”. Press the “Up” arrow until the display reads “AUTO”. Press the “Page” and “Scroll” buttons simultaneously to return to the home screen.
Fuse Replacement
If the Temperature Control Unit does not power up when the “Main” switch is turned on, replace the fuse on the back of the unit.
- Make sure the unit is unplugged from the power source.
- Press the fuse holder in and turn it counter-clockwise ¼ turn.
- Remove the fuse holder and replace the fuse.
- Push the fuse holder back into the receptacle and turn it clockwise ¼ turn to lock it in place.
- Plug the unit back into the power source and turn on the “Main” switch.
Warranty and Return Policy
Warranty:
OFI Testing Equipment, Inc. (OFITE) warrants that the Products shall be free
from liens and defects in title, and shall conform in all respects to the
terms of the sales order and the specifications applicable to the products.
All products shall be furnished subject to OFITE’s standard manufacturing
variations and practices. Unless the warranty period is otherwise extended in
writing, the following warranty shall apply: if, at any time prior to twelve
(12) months from the date of invoice, the products, or any part thereof, do
not conform to these warranties or to the specifications applicable thereto,
and OFITE is so notified in writing upon discovery, OFITE shall promptly
repair or replace the defective products. Notwithstanding the foregoing,
OFITE’s warranty obligations shall not extend to any use by the buyer of the
products in conditions more severe than OFITE’s recommendations, nor to any
defects which were visually observable by the buyer but which are not promptly
brought to OFITE’s attention.
In the event that the buyer has purchased installation and commissioning
services on applicable products, the above warranty shall extend for an
additional period of twelve (12) months from the date of the original
warranty expiration for such products.
In the event that OFITE is requested to provide customized research and
development for the buyer, OFITE shall use its best efforts but makes no
guarantees to the buyer that any products will be provided.
FITE makes no other warranties or guarantees to the buyer, either express or
implied, and the warranties provided in this clause shall be exclusive of any
other warranties including ANY IMPLIED OR STATUTORY WARRANTIES OF FITNESS FOR
PURPOSE, MERCHANTABILITY, AND OTHER STATUTORY REMEDIES WHICH ARE WAIVED.
This limited warranty does not cover any losses or damages that occur as a
result of:
- Improper installation or maintenance of the products
- Misuse
- Neglect
- Adjustment by non-authorized sources
- Improper environment
- Excessive or inadequate heating or air conditioning or electrical power failures, surges, or other irregularities
- Equipment, products, or material not manufactured by OFITE
- Firmware or hardware that has been modified or altered by a third party
- Consumable parts (bearings, accessories, etc.)
Returns and Repairs:
Items being returned must be carefully packaged to prevent damage in shipment
and insured against possible damage or loss. OFFICE will not be responsible
for equipment damaged due to insufficient packaging.
Any non-defective items returned to OFITE within ninety (90) days of the
invoice are subject to a 15% restocking fee. Items returned must be received
by OFITE in original condition for it to be accepted. Reagents and special
order items will not be accepted for return or refund.
OFFICE employs experienced personnel to service and repair equipment
manufactured by us, as well as other companies. To help expedite the repair
process, please include a repair form with all equipment sent to OFITE for
repair. Be sure to include your name, company name, phone number, email
address, detailed description of work to be done, purchase order number, and
a shipping address for returning the equipment.
All repairs performed as “repair as needed” are subject to the ninety (90) day
limited warranty.
All “Certified Repairs” are subject to the twelve (12) month limited warranty.
Returns and potential warranty repairs require a Return Material Authorization
(RMA) number. An RMA form is available from your sales or service
representative.
Please ship all equipment (with the RMA number for returns or warranty
repairs) to the following address:
OFI Testing Equipment, Inc.
Attn: Repair Department
11302 Steeplecrest Dr.
Houston, TX 77065
USA
OFFICE also offers competitive service contracts for repairing and/or
maintaining your lab equipment, including equipment from other manufacturers.
For more information about our technical support and repair services, please
contact techservice@ofite.com.
OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA /
Tel: 832-320-7300 / Fax:
713-880-9886 /
www.ofite.com