IMPORTANT
It is critical in all installations to ensure monitors’ antenna is positioned
vertically. This will achieve optimal signal strength, ensuring that you
receive data in a timely manner and prolong the battery life of the monitor.
PLEASE TAKE A MOMENT TO CAREFULLY READ THE INSTALLATION INSTRUCTIONS INCLUDED WITH YOUR MONITORS, AND ENSURE YOU UNDERSTAND AND RESPECT LOCAL REGULATIONS.
WARNING
Changes or modifications to the unit must only be performed by an authorized
technician. For outdoor use only. Explosion Hazard Do not open when an
explosive atmosphere is present. Potential electrostatic charging hazard –
wipe only with a damp cloth.
INSTALLATION
Always follow your local regulations and standards. If locally required,
consult with certified personnel to ensure your installation is compliant.
BATTERY REPLACEMENT
Please contact Otodata Support or your representative for battery replacement programs.
Specifications
Bluetooth Elite scale to weigh small-size industrial tanks up to 300kg
FCC Statement
This device complies with part 15 of the FCC Rules. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Operation is subject to the following two conditions: This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. This device is compliant with Industry Canada’s RSS standards for license-exempt radio apparatuses. Authorized use depends on the following two conditions: the device must not create radio interference, and the device user must accept all radio interference, even if this interference could potentially impair its functioning. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- increase the separation between the equipment and receiver.
- connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- consult the dealer or an experienced radio/TV technician for help.
Label on Device
ISED Non-interference Disclaimer
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s license-exempt
RSS(s).
Operation is subject to the following two conditions:
- This device may not cause interference
- This device must accept any interference, including interference that may cause undesired operation of the device.
RF Exposure Statement for ISED
This equipment complies with ISED RSS-102 radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed and
operated with minimum distance 20 cm (7.6 inches) between the radiator and any
part of your body. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
RF Exposure Statement for FCC
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter. In order to avoid the
possibility of exceeding the FCC radio frequency exposure limits, this
equipment should be installed and operated with minimum distance 20 cm (7.8
inches) between the antenna and your body during normal operation. Users must
follow the specific operating instructions for satisfying RF exposure
compliance.
Installation Instructions
Instructions are applicable to models ES3022 and ES3026
Step 1 Verify All Parts are in Good Condition
Before you begin, take a moment to verify if all parts are in good
condition, and all 4 legs are in place.
- Model ES3022, Small Elite Scale 650lb (300kg)
- Model ES3026, Large Elite Scale 2,200lb (1,000kg)
- If any parts are missing, contact your sales representative.
Step 2 Ensure the Scale is Perfectly Level
Place the scale on the floor where you intend it to be installed, and rotate
the legs up or down untill it is perfectly level. We strongly suggest using a
Bubble Level to verify if the scale is perfectly straight. Once done, tighten
the counter nuts to lock them in place.
Step 3 Install Wireless Bluetooth Monitor Within 25ft of the Elite Scale
Once your scale is leveled, it is time to install the Otodata Monitor. This
monitor has a powerful antenna that will intercept the signal from the Scale
and transmit the tank weight to the cloud.
- Install on roof, or
- exterior wall (affix with mounting bracket ACWMB1)
IMPORTANT
For correct operation, the Otodata Wireless Bluetooth Monitor should be installed as high up as possible in an area clear of major obstructions and should be no more than 25 feet (7.5m) from the Elite Scale.
Step 4 Mount Tank onto Scale
Exercising extreme caution, gently mount your tank onto the scale. Position
as perfectly centered as possible.
IMPORTANT DO NOT
let the tank hit/fall onto the scale as it can cause irreparable damage.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>