PENTAIR CC 50 Cartridge Filter User Guide
- June 5, 2024
- Pentair
Table of Contents
- PENTAIR CC 50 Cartridge Filter
- CUSTOMER SERVICE / TECHNICAL SUPPORT
- IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS
- GENERAL INFORMATION
- INSTALLATION
- Startup Instructions
- MAINTENANCE
- Cleaning the Filter
- TROUBLESHOOTING
- Pressure Loss Chart
- Flow Rates
- REPLACEMENT PARTS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PENTAIR CC 50 Cartridge Filter
CUSTOMER SERVICE / TECHNICAL SUPPORT
If you have questions about ordering Pentair replacement parts, and pool products, please contact:
Customer Service and Technical Support, USA (8 A.M. to 4:30 P.M. — Eastern/Pacific Times)
- Phone: 800-831-7133
- Fax: 800-284-4151
- Web site Visit www.pentair.com for information about Pentair products.
Sanford, North Carolina (8 A.M. to 4:30 P.M. ET)
Phone: 919-566-8000
Fax: 919-566-8920
Moorpark, California (8 A.M. to 4:30 P.M. PT)
Phone: 805-553-5000 (Ext. 5591)
Fax: 805-553-5515
IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS
IMPORTANT NOTICE:
This guide provides installation and operation instructions for the this
filter. Consult Pentair Water Pool and Spa, Inc. with any questions regarding
this equipment.
Attention Installer: This guide contains important information about the
installation, operation and safe usage of this product. This information
should be given to the owner and/or operator of this equipment after
installation.
Attention User: This manual contains important information that will help
you in operating and maintaining this filter. Please retain it for future
reference.
- This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
- Warns about hazards that can cause death, serious personal injury, or major property damage if ignored.
- Warns about hazards that may cause death, serious personal injury, or major property damage if ignored.
- Warns about hazards that may or can cause minor personal injury or property damage if ignored.
- Indicates special instructions not related to hazards.
Note: Carefully read and follow all safety instructions in this manual and on equipment. Keep safety labels in good condition; replace if missing or damaged.
Consumer Information and Safety
This filter is designed and manufactured to provide many years of safe and
reliable service when installed, operated and maintained according to the
information in this manual and the installation codes referred to in later
sections. Throughout the manual, safety warnings and cautions are identified
by the “ “ symbol. Be sure to read and comply with all of the warnings and
cautions.
Before installing this product, read and follow all warning notices and
instructions which are included. Failure to follow safety warnings and
instructions can result in severe injury, death, or property damage. Call
800-831-7133 for additional free copies
of these instructions or replacement safety labels.
Do not operate the filter until you have read and understand clearly all the
operating instructions and warning messages for all equipment that is a part
of the pool circulating system. The following instructions are intended as a
guide for initially operating the filter in a general pool installation.
Failure to follow all operating instructions and warning messages can result
in property damage or severe personal injury or death.
- Due to the potential risk that can be involved it is recommended that the pressure test be kept to the minimum time required by the local code. Do not allow people to work around the system when the circulation system is under pressure test. Post appropriate warning signs and establish a barrier around the pressurized equipment. If the equipment is located in an equipment room, lock the door and post a warning sign.
- Never attempt to adjust any closures or lids or attempt to remove or tighten bolts when the system is pressurized. These actions can cause the filter to separate and could cause severe personal injury or death if they were to strike a person.
- This filter must be installed by a qualified pool serviceman in accordance with all applicable local codes and ordinances. Improper installation could result in death or serious injury to pool users, installers, or others and may also cause damage to property.
- Always disconnect power to the pool circulating system at the circuit breaker before servicing the filter. Ensure that the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the filter. Failure to do so could result in serious injury or death to serviceman, pool users or others due to electric shock.
- DO NOT permit children to use this product.
THIS SYSTEM OPERATES UNDER HIGH PRESSURE
When any part of the circulating system, (e.g., closure, pump, filter,
valve(s), etc.), is serviced, air can enter the system and become pressurized.
Pressurized air can cause the top closure to separate which can result in
severe injury, death, or property damage. To avoid this potential hazard,
follow these instructions:
-
Let air and pressure out of system before and after servicing.
a. Shut off pump and RELIEVE PRESSURE by opening the manual air/pressure relief valve before servicing.
b. Follow Startup Instructions exactly after completing service (page 3). The air/pressure relief valve must remain open until water comes out, allowing all air out of the system. -
Install lock ring properly.
a. Follow Lock Ring Installation Instructions exactly (page 3). -
Maintain circulation system properly to help prevent air entering the system.
a. Replace worn or damaged parts immediately, (e.g., closure, pressure gauge, valve(s), O-rings, etc.).
b. Maintain proper water level in the pool or spa. -
Verify that the return line to the pool is unobstructed. Ensure return valves are open and any winterizing plugs are removed.
AVOID DAMAGING SYSTEM
Never Exceed Maximum Pressure of Components. The maximum working pressure of
this filter is 50 psi. Never
subject this filter to higher pressure, even when conducting hydrostatic
pressure tests. Pressures above 50 psi can damage your filter.
Be sure the maximum pressure of the filter system does not exceed the maximum
pressure of any components within the system
(typically stated on each component), including during hydrostatic or external
leak tests. Exceeding the maximum pressure of a component can result in that
component failing. If you do not know the pool or spa system operating
pressure, install an ASME approved automatic Pressure Relief or Pressure
Regulator in the circulation system set to the lowest working pressure of any
of the components in the system.
Certain codes may require pressure testing the system. Performing pressure tests increases the risk of component failure. Due to the potential risk that can be involved, keep the pressure test to the minimum time required by the local code and take precautions. If pressure testing is necessary, follow these precautions:
-
Keep people away.
a. Do not allow people to work around the system when the circulation system is under pressure test. Post appropriate warning signs and establish a barrier around the pressurized equipment. If the equipment is located in an equipment room, lock the door and post a warning sign. -
Never exceed maximum operating pressure.
a. When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing system, ensure that the Maximum Pressure that the filtration system will be subjected to does not exceed the maximum working pressure of any of the components contained within the system.
GENERAL INFORMATION
THIS SYSTEM OPERATES UNDER HIGH PRESSURE.
When any part of the circulating system (e.g., Lock Ring, Pump, Filter,
Valves, etc.) is serviced, air can enter the system and become pressurized.
Pressurized air can cause the lid to separate which can result in serious
injury, death, or property damage. To avoid this potential hazard, follow the
instructions below.
General Operation Information
Read and follow all instructions and warnings before installing or servicing
your filter. Proper installation and operation can prevent unnecessary repairs
and maintenance.
Warning: Your filter is a piece of machinery, do not tamper with it,
attempt to disassemble it or otherwise adjust it unless you fully understand
it’s operation. Serious injury or death can occur if the equipment is
improperly handled. Consult a pool service professional for maintenance and
service assistance.
- The Clean and Clear® RP Cartridge Filter operates under pressure. When the lock ring is installed properly and operated without air in the water system, this filter will operate in a safe manner.
- The maximum working pressure of this filter is 50 psi. Never subject this filter to pressure in excess of this amount, even when conducting hydrostatic pressure tests.
- Be sure the maximum pressure of the filter system does not exceed the maximum pressure of any components within the system during hydrostatic or external leak tests. Consult the maximum pressure stated on each component of the system.
- The pressure gauge is the primary indicator of how the filter is operating. Maintain your pressure gauge in good working order.
- Clean your filter when pressure reads between 8- 10 psi higher than the “Original Starting Pressure”, or when significant reduction in flow is noticed. The pressure reading increases as it filters dirt from your pool. This build up of pressure will vary due to different bathing loads, temperature, environmental conditions, etc.
Note: When using a variable speed pump the “Original Starting Pressure” will be dependent on the pump speed (RPM) when recording the original operating pressure. Record the “Original Pump RPM” in Table 1.
Note: When the cartridge element filter is used on new pools and after cleaning the elements, introduce into the system 0.5 pounds of diatomaceous earth per every 100 square feet of filter area, (a one-pound coffee can equals 0.5 pounds of diatomaceous earth). Mix the diatomite with water and pour it into the skimmer after the pump is primed and the system is operating. This will enhance the filtration of your water.
Pressure Tests
When performing hydrostatic pressure tests or when testing for external leaks
of the completed filtration and plumbing system, ensure that the Maximum
Pressure that the filtration system will be subjected to DOES NOT EXCEED THE
MAXIMUM WORKING PRESSURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM.
In most cases, the maximum pressure will be stated on each component of the
system.
If you do not know the pool or spa system operating pressure, install an ASME
approved automatic Pressure Relief or Pressure Regulator in the circulation
system set to the lowest working pressure of any of the components in the
system.
TABLE 1
ORIGINAL STARTING PRESSURE IS: ____ psi. (pounds per square inch)
SERVICE THE CARTRIDGES AT: __ psi.
ORIGINAL PUMP RPM: __ rpm. (for Variable Speed Pumps Only)
INSTALLATION
Warning: This filter must be installed by a qualified pool technician in
accordance with all applicable local codes and ordinances. Improper
installation could result in death or serious injury to pool users,
installers, service persons, or others and may also cause damage to property.
For Installation of Electrical Controls at Equipment Pad (ON/OFF Switches,
Timers, Control Systems and Automation) Install all electrical controls at the
equipment pad, such as ON/OFF switches, timers, control systems, etc. to allow
the operation (startup, shutdown or servicing) of any pump or filter so the
user does not place any portion of his/her body over or near the pump strainer
lid, filter lid or valve closures. This installation should allow the user
enough space to stand clear of the filter and pump strainer lid during system
startup, shutdown or servicing of the system filter.
Filter Location
-
The Clean and Clear® RP Cartridge Filter should be mounted on a level concrete slab. Position the filter so that instructions, warnings and the pressure gauge are visible to the operator and readable. It also should be positioned so that the piping connections, control valve and waste drain plug are convenient and accessible for servicing and winterizing.
-
Be certain to install electrical controls (e.g., on/off switches, timers, control systems, etc.) so that the user is allowed enough space to stand clear of the filter and pump during startup, shutdown or servicing.
-
Allow sufficient clearance around the filter to permit visual verification that the lock ring is properly installed around the tank flanges, see Figure 1.
-
Allow sufficient space above the filter to remove the filter lid for cleaning and servicing. This distance will vary with the model of filter you are using. See Table 2 for the required vertical clearance.
-
Position the filter to safely direct water drainage away from electrical equipment or anything that might be damaged.
-
Position the High Flow™ Manual Air Relief Valve to safely direct purged air or water.
Warning: RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. Water discharged from an improperly positioned filter or valve can create an electrical hazard that can cause severe personal injury as well as damage property.
Filter Plumbing
Make all plumbing connections in accordance with local plumbing and building
codes. Do not use pipe joint compound, glue or solvent on the bulkhead
connections. The provided filter plumbing connections include an O-ring seal.
Caution: Use PTFE or silicone based lubricants when lubricating the
O-rings on the union and bulkhead couplings. Use of petroleum based products
will damage the equipment.
Lock Ring Installation Instructions
THIS SYSTEM OPERATES UNDER HIGH PRESSURE.
When any part of the circulating system (e.g., Lock Ring, Pump, Filter,
Valves, etc.) is serviced, air can enter the sys-tem and become pressurized.
Pressurized air can cause the lid to separate which can result in serious
injury, death, or property damage. To avoid this potential hazard, follow the
instructions below.
These instructions MUST BE FOLLOWED EXACTLY to prevent the lid from separating
during system restart or later operation.
-
Perform the following steps before working on any part of the circulating system (e.g., lock ring, pump, filter, valves, etc.).
a. Turn the pump off and shut off any automatic controls to ensure that the system is not inadvertently started during servicing.
b. Open the High Flow™ manual air relief valve.
c. Wait until all pressure is relieved. Never attempt to assemble, disassemble or adjust the filter lock ring while there is any pressure in the filter. -
Be certain the O-ring is in position in the lower tank half. Place the filter lid over the lower tank half, making sure it is fully and firmly seated on the tank half, see Figure 2.
-
Place lock ring over the tank lid, and centering the lock ring on the threads of the tank body. Turn the lock ring clockwise until the safety latches click and the lock ring hits the stops on the body. DO NOT ATTEMPT TO OVER-TIGHTEN THE LOCK RING AFTER LOCK RING HAS HIT THE STOPS ON THE BODY.
-
Follow the Startup Instructions below.
Startup Instructions
Warning: THIS SYSTEM OPERATES UNDER HIGH PRESSURE.
When any part of the circulating system (e.g., Lock Ring, Pump, Filter,
Valves, etc.) is serviced, air can enter the sys-tem and become pressurized.
Pressurized air can cause the lid to separate which can result in serious
injury, death, or property damage. To avoid this potential hazard, follow the
instructions below.
-
Open the High Flow™ manual air relief valve until it snaps
into the full open position (this only requires a quarter turn counterclockwise). Opening this valve rapidly releases air trapped in the filter. -
Stand clear of the filter tank, then start the pump.
-
Close the manual air relief valve after a steady stream of water appears.
-
The system is not working properly if either of the following conditions occur.
a. A solid stream of water does not appear within 30 seconds, after the pump’s inlet basket fills with water.
b. The pressure gauge indicates pressure before water outflow appears.
If either condition exists, shut off the pump immediately, open valves in the water return line to relieve pressure, and clean the air relief valve, see Cleaning the Manual Air Relief Valve on page 4. If the problem persists, call 800-831-7133 for assistance.
MAINTENANCE
Maintaining the Pressure Gauge
The pressure gauge is the primary indicator of how the system is operating, so
correct functioning is critical. Replace the pressure gauge (Pentair P/N
190058) if it does not meet the requirements below:
- Pressure gauge should go to zero (0) when the system is turned off and pressure is relieved.
- Pressure gauge should indicate pressure when the system is operating.
- The pressure gauge should be readable and not damaged in anyway
Cleaning the Manual Air Relief Valve
RECOMMENDED EQUIPMENT:
- 5/16″ Drill Bit (to check air passage)
- Silicone-based Lubricant (if needed)
PROCEDURE:
-
Shut off pump and relieve pressure.
a. Turn the pump OFF and shut OFF any automatic controls (e.g., timers) and disconnect power to ensure that the system is not inadvertently started during maintenance.
b. Open the manual air relief valve by turning the valve cover assembly a quarter turn counter-clockwise until it snaps into the full open position.
c. Stand clear of the filter and wait until all pressure is relieved. Pressure gauge must read zero (0 psi). -
With the relief valve attached to the Clean and Clear® RP Cartridge
Filter tank, pull out the locking tabs and unlock the valve stem and cover assembly from the valve body with a counter-clockwise turn, see Figure 3. -
Pull the valve stem and cover assembly straight up and away from the valve body.
-
Clean and check the valve stem and body:
a. Clean off any debris.
b. Verify that the filter tank’s air passage is open by inserting a 5/16″ drill bit through the valve body.
c. Verify that the valve stem O-rings are in good condition, properly positioned, and lubricated with a silicone-base lubricant.
Caution: If needed, use only a PTFE or silicone-base lubricant on the O-rings. Use of petroleum-based products on O-rings will damage the equipment. -
Reinstall the valve stem and cover assembly with a downward and clockwise motion until it snaps into position.
Cleaning the Filter
Warning: The following information should be read carefully since it outlines the proper manner of care and operation for your filter system. As a result of following these instructions and taking the necessary preventative care, you can expect maximum efficiency and life from your filter system.
-
Turn the pump off, shut off any automatic controls to ensure that the system is not inadvertently started during servicing.
-
Open the filter High Flow™ manual air relief valve (and the waste drain valve, or cap, if your system has one).
-
Remove hair and lint strainer pot lid and clean basket. Replace basket and secure lid.
-
Disconnect air relief drain hose if installed.
-
Remove lock ring by depressing safety latches on both sides of ring and rotate counterclockwise, then remove tank lid.
-
Remove the element assembly by placing hands in lifting handles and pulling straight up on the element assembly.
-
Remove the cartridge element from the center support tube.
-
Using a garden hose with a nozzle, direct water spray at the cartridge element to dislodge and wash away accumulated foreign matter. Water may be sprayed at the outside as well as the inside of the cartridge element for thorough cleaning.
-
For cartridges used in pools or spas where high levels of perspiration, suntan lotions and other oils are present:
a. Soak the cartridge for at least one hour (overnight is most effective) in one of the following:-
A commercial filter cleaner
Warning: Heed all manufacturers’ instructions and warnings when using polyhexamethylene biguanide sanitizers or other cartridge filter cleaner solutions. -
One cup trisodium phosphate (TSP) to five gallons of water
-
One cup dishwasher detergent to five gallons of water
-
Rinse the cartridge to remove oils and cleaning solution.
Caution: Failure to remove all oils and cleaning solutions before acid soaking will result in permanent restriction of water flow through the filter and will cause premature cartridge failure.
-
-
Direct the water spray to wash out the inside of the tank body and bottom manifold. Water and debris will drain out through the open drain plug.
-
Check gasket around outer lip of bottom plate. Gasket must be firmly and evenly set around the entirety of the outer lip.
-
Turn the cartridge element over several times during the washing operation to clean the media thoroughly.
-
Clean and remove debris from inside the filter tank and from the O-ring and O-ring groove on the tank body.
-
Replace clean cartridge element on support tube and install assembly into the filter tank body, aligning the arrow on the support tube with the inlet port of the filter, making sure it is fully seated. Make sure the internal air relief screen is attached to the top of the element support tube.
-
Replace the tank lid onto the tank body making sure it is fully and firmly seated on the tank body.
-
Place lock ring over tank lid, and centering the lock ring on the threads of the tank body, turn the lock ring clockwise until the safety latches click and the lock ring hits the stops on the body. DO NOT ATTEMPT TO OVER-TIGHTEN THE LOCK RING AFTER LOCK RING HAS HIT THE STOPS ON THE BODY.
Note: Any time the filter tank is opened, and/or element assembly is removed, be sure to generously coat the O-ring with silicone lubricant before reassembling the unit. DO NOT USE PETROLEUM BASED LUBRICANTS BECAUSE THEY HAVE A DETERIORATING EFFECT ON RUBBER. -
Replace drain cap and reinstall manual air relief valve drain hose if used.
Replacing the Cartridge Element
Cartridge element life will vary with pool conditions such as bather load,
wind, dust, etc. You can expect an average media life of three (3) years under
normal conditions.
To replace cartridge element follow steps in Cleaning the Filter above.
TROUBLESHOOTING
-
Air entering your filter is dangerous and can cause the lid to separate. Correct any conditions in your filtration system that allow air to enter the system.
Some common ways to identify air entering the system:
a. Low water level in pool or spa – skimmer is starving for water with pump running. Add water to pool or spa.
b. Air bubbles or low water level in pump hair and lint pot are caused by; low water level, clogged skimmer basket, split suction cleaner hose, leak in pump hair and lint pot lid, or leak in pump suction line.
c. Air bubbles coming out of water return lines into pool or spa with pump running.
d. Air is discharged from the air relief valve on top of the filter when the valve is opened with the pump running. -
Until the water initially put into the pool has been completely filtered, short filter cycles in between cleanings are normal. In most cases pool owners are dismayed by the undesirable color and appearance of water in a newly filled pool. Plaster dust can be responsible for short filter cycles, requiring frequent cleaning.
-
If pressure drops on gauge, check skimmer basket and pump basket first for debris. If the baskets are clean, shut off power to pump and turn off any automatic controls. Then turn motor shaft with your fingers. If it turns freely then the pump must be disassembled and the impeller checked to see if it is clogged. If it is not frozen or clogged then there is an obstruction in the line between the pool and the pump.
-
The pressure gauge is an important part of the filter system. It is your primary indicator of
how the system is operating. Maintain your pressure gauge in good working order. Check the operation of your pressure gauge in the following manner:
a. The pressure gauge should go to zero (0) when the system is turned off and pressure is relieved.
b. The pressure gauge should indicate pressure when the system is operating.
c. The pressure gauge should be readable and not damaged in any way.
d. Replace the pressure gauge if it does not meet the requirements above.
Pressure Loss Chart
Flow Rates
- Recommended flow rate for residential is 0.5 GPM per sq. ft.
- Commercial flow rate is a maximum of 0.375 GPM per sq. ft. of filter area.
NOTE: Actual system flow will depend on plumbing size and other system components.
REPLACEMENT PARTS
Item Part# Description
1 | 98209800 | High Flow Manual Air Relief Calve |
---|---|---|
2 | 190058 | Pressure Gauge |
3 | 178548 | Lid, 100 sq. ft. Filter |
4 | 178546 | Lid, 150, 200 sq. ft. Filter |
5 | 59052900 | Lock Ring Assembly |
6 | 87300400 | Body O-Ring |
7 | 59016200 | Air Bleed Sock Kit |
8 | 59053700 | Center Core, 100 sq. ft. Filter |
9 | 59053800 | Center Core, 150, 200 sq. ft. Filter |
10 | R173215 | Cartridge Element, 100 sq. ft. Filter |
11 | R173216 | Cartridge Element, 150 sq. ft. Filter |
12 | R173217 | Cartridge Element, 200 sq. ft. Filter |
13 | 178731 | Tank Bottom |
14 | 154712Z | Drain Cap Assembly (before 10/17) |
14 | 190030Z | Drain Cap Assembly (after 10/17) |
15 | 178732 | Union Nut “C” Clip |
16 | U11-200PS | Union Nut |
17 | 178746 | Union Diamond Seal |
18 | 178733 | Union, Threaded Half |
1620 HAWKINS AVE., SANFORD, NC 27330 •
919-566-8000
10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 •
805-553-5000
WWW.PENTAIR.COM
All Pentair trademarks and logos are owned by Pentair or one of its global
affiliates. Clean & Clear® and High Flow™ are trademarks and/or registered
trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies
in the United States and/ or other countries. Unless expressly noted, names
and brands of third parties that may be used in this document are not used to
indicate an affiliation or endorsement between the owners of these names and
brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the
trademarks or registered trademarks of those third parties. Because we are
continuously improving our products and services, Pentair reserves the right
to change specifications without prior notice. Pentair is an equal opportunity
employer.
© 2018 Pentair Water Pool and Spa, Inc. All rights reserved. This document is
subject to change without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>