flowkey HY02TP Wi-Fi Plug In Thermostat User Manual

June 5, 2024
flowkey

Flowkey HY02TP Wi-Fi Plug-In Thermostat

flowkey-HY02TP-Wi-Fi-Plug-In-Thermostat-Product

Instruction

Many thanks for your selection of our products and services, and also for your trust and support of us.

  • Search for ” Smart RM ” or “Smart Life” Download the Wifi App with the following icon.
  • Turn on the thermostat, press and hold the key combination “ ” and “ ” Activate the WIFI distribution network icon.

Feature

  • EU,FR,AU,USA,IT etc socket for choice
  • 0.5°C accuracy keeps the temperature within the level you set.
  • Children lock to prevent misoperation by children
  • weekly programming mode includes: 5+2, 6+1, 7 days three modes, and can be DIY programming.
  • The classic holiday mode allows you to enjoy a comfortable temperature during your holiday.
  • Temporary manual mode: In the automatic mode, set the temperature, the thermostat will run for a period according to the set temperature, and then return to the automatic mode.

Product Specifications

  • Power:90-240VAC 50/60HZ
  • Probe Sensor: NTC(10k)1%
  • Current:16A
  • Limit temperature range:1~70°C
  • The default setting temperature range:5~50°C
  • Max. control accuracy:±0.5°C
  • Size: 1406740mm

Feature description of icons and buttons

  • Manual mode
  • Auto mode
  • Temporary manual mode and press to set the clock, short press, or adjust the value. After finishing all, press.

Timer on/offsetting

Open and set the timer on function: Long press for 3-5 seconds to enter the setting interface, short press to choose the ON icon, then short press to enter the timer on the setting, the default time ” ” means that the timer on function is off. Short press to set hours and minutes, short press or to adjust the value. After finishing all, press. Open and set the timer off function: Long press for 3-5 seconds to enter the setting interface, short press to choose the OFF icon, then short press to enter the timer on the setting, the default time ” ” means that the timer off function is off. Short press to set hours and minutes, short press or to adjust the value. After finishing all, press.

Weekly Programmable Setting

5+2 (factory default), 6+1, and 7 models 6 times period setting in the advanced options, power-on state, long press for 3-5 seconds enter into programming mode setting, then short press choose, then press to set: hour, minute, time period, short press or to adjust the value. After finishing all, press

flowkey-HY02TP-Wi-Fi-Plug-In-Thermostat-Fig2

The optimum comfort temperature is 18°C-22°C.

Holiday mode setting

Long press for 3-5 seconds to enter the setting interface, press to choose and press to set holiday mode, and short press or to adjust the value. After finishing all, press

Advanced options

  • Turn off the thermostat, and long press for 3-5 seconds to access the advanced options setting.
  • Holiday mode, Holiday days, and temperature can be set to run in countdown mode
  • Heating, the icon disappears means stop heating Clock
  • WIFI connection, flashing EZ distribution mode Wifi status: Disconnection
  • Cloud icon: flashing, add a thermostat to APP with AP mode Children lock
  • Open descaling function Open antifreeze function Flashing indicates the timer on/off function is open

flowkey-HY02TP-Wi-Fi-Plug-In-Thermostat-Fig1

Key Function

  • ON/OFF Turn on/off key
  • Short press SET to open or close descaling function
  • Turn on the thermostat, long press for 3-5 seconds to enter into setting interface
  • Turn off the thermostat, long press for 3-5 seconds to enter into the advanced options setting
  • Confirm key: use it with SET key + : Turn on thermostat, press and hold for pairing Wifi
  • Decrease key, long press to lock /unlock keys
  • Increase key
  • In the Auto mode, press or enter into temporary manual mode

Clock setting

Long press for 3-5 seconds to enter the setting interface, press to choose From A1 to A9, short press to choose the option, and adjust data by, short press to switch next option. Remain about 5 seconds after the setting is finished will save and quit setting.

NO| Setting Options| Data Setting Function| Factory

Default

---|---|---|---
A1| Working mode| 0 Manual mode        1  Auto mode| 0

A2

| Start/stop working

temperature difference setting

| 0.5-2.5°C| 1°C
A3| Setting temperature

maximum limit

| 20-70℃| 50℃

A4

| Setting temperature minimum limit| 1-10℃| 5℃

A5

| Measuring Temperature

Calibration

| -9-+9°C| -1°C

A6

| Low temperature protection setting| 1.  1-10°C

2. Exceed 10°C, screen display          , l ow temperature protection was canceled.

|

A7

| Turn on/off state memory after electricity cut| 0:Keep the same state(on/off) as electricity return

1:Turn off state after electricity return

2:Turn on state after electricity return

| 0

A8

| Run weekly

programming selection

| 0:(5+2)/1:(6+1)/2:(7days)| 0

A9

|

Reset factory setting

| Display A o, press         key till whole icons show|