**** IMPORTANT ****

Damage can occur to A/D circuitry if the SENSE parameter is not correctly configured for the load cell cable used.
The SENSE parameter is set to 4-WIRE by default but must be changed to 6-WIRE for applications that use a 6-WIRE cable.

Configure the SENSE parameter using the front panel of the 680.

  1. Access setup mode by pressing the setup switch, and config displays.
  2. Press capacity displays.
  3. Press sense displays.
  4. Press to view the current wire setting for the SENSE parameter, displays.
  5. Press to change the setting and displays.
  6. Press to accept the SENSE parameter setting.
  7. Press to return to weigh mode.

Route the load cell cable to the J1 connector on the 680 CPU board and refer to the figures and table below for 4- and 6-wire cable wiring. For a 6-wire installation, the SENSE parameter must be set to 6-WIRE in the CONFIG menu.

SENSE Parameter set to 4-WIRE

Pin Function
1 + SIG
2 – SIG
3 + SENSE
4 – SENSE
5 + EXC
6 – EXC

SENSE Parameter set to 6-WIRE

Note For a 4-wire installation leave pins 3 and 4 empty on the J1 connector.
Please refer to the 680 Technical Manual (PN 192627) for complete installation instructions and for additional details on accessing setup mode and the CONFIG menu, if needed.

PN 209029

Documents / Resources

| ricelake 192627 SYNERGY PLUS DIGITAL WEIGHT INDICATOR TECHNICAL [pdf] User Manual
192627 SYNERGY PLUS DIGITAL WEIGHT INDICATOR TECHNICAL, SYNERGY PLUS DIGITAL WEIGHT INDICATOR TECHNICAL, DIGITAL WEIGHT INDICATOR TECHNICAL, INDICATOR TECHNICAL
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ricelake User Manuals

Related Manuals