LumiCleanse LC-UVC-AIR-350 Ultraviolet Germicidal Air Purifier User Manual

June 5, 2024
LumiCleanse

LumiCleanse LC-UVC-AIR-350 Ultraviolet Germicidal Air Purifier User Manual

LumiCleanse LC-UVC-AIR-350 Ultraviolet Germicidal Air
Purifier.jpg

LC-UVC-AIR-350

FIG 1 Feature.JPG

FIG 2 Light efficient design.jpg

Thank you for purchasing a LUMICLEANSE product. You have acquired a powerful and versatile product. We are confident that you will be satisfied with our excellent product and service. For your own safety, please read this user manual carefully before operating the product.

Voltage Input: AC120V~, 60Hz; Power: 350W; Product Size: 457x429x1075mm
This product is for commercial use, such as in conference rooms, offices, hotels, schools, theaters, waiting rooms, restaurants, etc.

IMPORTANT!
When using electrical equipment, basic safety precautions should always be followed. READ AND FOLLOW ALL SAFETY INSTRUCTIONS carefully before using this product, save it for future reference.

  • Check and make sure the voltage indicated on this product corresponds to the localpower voltage before connecting this product to the power socket.
  • Do not use this product if the plug, power cable, or the product itself is damaged. If anything is damaged, it must be replaced or repaired before using, to avoid a hazard.
  • Always place and use the product on a dry, stable, level and horizontal surface. Do not use the product in wet surroundings or in surroundings with high ambient temperatures, or near gas products, heating devices or fireplaces.
  • Do not use the product in a room with major temperature changes, as this may cause condensation inside the product.
  • If you need to move the product, disconnect the product from the power supply first. Do not move the product by pulling its power cable.
  • Always engaged the wheels brakes during use or storage, to avoid accidentally moving by itself.
  • Do not block the air inlet and outlet by placing any items on the air inlet and outlet.
  • Do not use this product for other than intended use.
  • Make sure that foreign objects do not fall into the product through the air outlet.
  • Do not let water, other liquid or flammable detergent enter this product, to avoid risk of electric shock or fire hazard.
  • Do not sit or stand on the product. Sitting or standing on the product may lead to potential damage or injury.
  • Do not clean this product with water, chemicals, or flammable solvents, to avoid risk of electric shock or fire hazard.
  • Always unplug the product after use and before cleaning, or carrying out other maintenance or replacing any accessory.
  • Only use the original accessory specially intended for this product. Do not use any other accessory. The use of accessory not recommended by the manufacturer may cause an unsafe condition.

1. Product Overview

FIG 3 Product Overview.jpg

2. Control Panel Overview

Display Panel:

FIG 4 Display Panel.JPG

Control Buttons:

FIG 5 Control Buttons.JPG

FIG 6 Control Buttons.JPG

Indicator Lights & Audio Alarm:

FIG 7 Indicator Lights & Audio Alarm.JPG

3. Using The Product

3.1 Before Use

  • Always place the product on a stable and flat surface with the universal wheels brakes engaged before and during use.
  • For best purification and disinfection performance, close all the doors and windows.
  • Keep curtains, clothes, papers, etc… away from the air inlet or outlet.

For air purification, this product can detect and provide the current PM2.5 feedback. Most of the indoor air pollutants fall under PM2.5, such as tobacco smoke, some bacteria, mold spores, dust, allergen, etc…. Air quality indications for reference:

FIG 8 Using The Product.JPG

This product is designed with UV lamps inside, the UVC can do high efficient disinfection to the air which going through this product during the air purification process.
The suggestion on disinfection area and time for reference:

FIG 9 Using The Product.JPG

Note: time could be different depending on the actual height and structure of the room.

3.2 Operation
Control Panel Operation:

FIG 10 Control Panel Operation.JPG

*If need to change the time mode after operation started, need to stop operation first.

Remote Control Operation:

FIG 11 Remote Control Operation.JPG

WIFI APP Operation

  • Connect your mobile phone to the LAN network.
  • Make sure the LAN network you connected is 2.4G WIFI, not 5G WIFI.
  • One LAN network is only for one user to bind device, not for multi-user.

Download “GOLDENSEA UV” APP from App store or Android market and install into your mobile phone. Steps to Connect your device to the LAN network and Bind:

FIG 12 WIFI APP Operation.JPG

FIG 13 WIFI APP Operation.JPG

FIG 14 WIFI APP Operation.JPG

7. Now you can control the device from the APP.

4. Moving The Unit

This product has been integrated with 3 universal wheels for fast and easy relocation.

Before moving the product, make sure the power cable is disconnected from power socket.

Simply push the brake lever down to engage the brake; or lift the lever to release the brake.

*Always place the product on a stable and flat surface with the universal wheels brakes engaged during use or storage.

5. Fall Protection

When a working product detects a movement of more than 45°, it will automatically shut off for safety.

There will be audio alarm and flashing green indicator light to alert the operator.

To re-start the unit after fall protection, put the product back to the normal upright position, make sure the power plug is still well-connected to power socket, re-start the operation again from the beginning.

Should a qualified technician check for damage before re-starting the unit after a fall.

6. Open Door Protection

If the front door of the product is opened during use by accident or by misuse, the product will automatically turn off for protection purpose.

There will be audio alarm and flashing green+blue indicator lights to alert the operator.

Once the door is closed again, the operation process will continue.

The front door can be closed or opened by simply pushing in on the right side of the door.

The other two doors can be opened by pushing out from inside.
Do not open the doors unless there is need for service or maintenance.

7. Dimensional Drawings

FIG 18 Dimensional Drawings.jpg

8. Replacing and Cleaning The Filters

  • Always turn off the product and unplug from the socket before replacing the filters.
  • The HEPA and Active Carbon Filters are not washable or reusable.
  • Before carrying out any replacement and cleaning, wait about 15 minutes after switchingoff the product (to let the UV tubes cool down to avoid scalding).

8.1 Replacing the HEPA and Active Carbon Filters
Filter Replacement Indicator:
This product is equipped with a filter replacement indicator to make sure that the air purification filter is in optimal condition when operating. When the filters need to be replaced, the icon of “Filter Replacement Indicator” turn from white to red and stay flashing. If the filters are not replaced in time, the product will stop operating and automatically lock to protect the air quality in the room. Replace the filters as soon as possible. Remember, non professionals are not allowed to change the filter by themselves.

FIG 20 Filter Replacement Indicator.jpg

FIG 21 Filter Replacement Indicator.jpg

FIG 22 Filter Replacement Indicator.jpg

The product is now ready for use again.

FIG 23 Clean the Pre-filters.JPG

9. Replacing The UV Lamps

To maintain the sterilizing efficacy, the UV tubes need to be replaced after 9,000 hours of use. When the lamps need to be replaced, the icon of “Lamp Replacement Indicator” turn from white to red and stay flashing.

If the lamps are not replaced in time, the product will stop operating and automatically lock to protect the disinfection effect in the room. Replace the lamps as soon as possible.

FIG 24 Replacing The UV Lamps.jpg

  • Before carrying out any replacement, wait about 15 minutes after switching off the product (to let the UV tubes cool down to avoid scalding).

Steps:

FIG 25 Replacing The UV Lamps.jpg

FIG 26 Replacing The UV Lamps.jpg

FIG 27 Replacing The UV Lamps.jpg

FIG 28 Replacing The UV Lamps.jpg

10. Troubleshooting Tips

10.1 What to do if the product doesn’t work?

  1. Ensure the product is plugged into a working socket, plug is wired correctly and terminal well-connected.
  2. Ensure the power switch is switched to “on” < I >.
  3. Check if the door is opened by accident or misuse. Push the door in to close it.

10.2 How often should the UV tube be replaced?

  1. The UV tube is the core of the product, it should be replaced after 9000 hours of use to maintain the germicidal efficacy. If it needs to be replaced, the icon on display will turn from white to red.
  2. If the UV tube is defected or damaged, please contact your local dealer or our customer service to order a new UV tube. For replacing the UV tube, please refer to the instructions in this user manual.
  3. After use for a period of time, it is normal to find some black spots on the UV tube.

10.3 Why airflow coming out from the air outlet is significantly weaker than before?
1.Check if the pre-filter is dirty, if so, clean the pre-filter.

10.4 Why the display still show the alert icon of replacing filter/lamp even after it is just replaced?
1.Check if you have reset the filter/lamp in the display menu after replacement.

11. Features

Light Source

  • Lamp: TUV PL-L 36W/4P 1CT/25 (PHILIPS) or HNS L 36W 2G11 GFT36DL/2G11/SE/OF PURITEC UV-C Germicidal Low Pressure Lamp (OSRAM)
  • The UV-C wavelength is 253.7nm.
  • Extremely long Life: up to 9,000 H

Features

  • Disinfection time settings
  • Fan speed settings
  • Control panel with touch keys
  • Remote control
  • Control with APP
  • Visual indicator lights
  • Audio alarm
  • Power switch
  • Movable with wheels
  • Fall protection

Product Type

  • Commercial Air Purifier

Weight

  • Net weight: 26.73 kg

12. Cleaning and Maintenance

  1. To ensure the device remains in good condition and does not fail prematurely, regular maintenance, cleaning and checks are required.
  2. For cleaning of the device, please use a lint-free cloth.
  3. To avoid damage to the device, never use detergent or solvents.
  4. Never spray insecticide towards the device, it can discolor or damaged.
  5. Should you need any spare parts, please order genuine parts from your local dealer.

13. Recycling

To protect the environment and human health, do not throw away the product with the normal household waste at the end of its life, hand it to your local collection point for recycling. Follow local rules for the separate collection of electrical and electronic products.

14. Service

For all service needs, please contact your local authorized dealer or Light Efficient Design customer service. Our contact details are:

Light Efficient Design
188 S. Northwest Highway.Cary,IL 60013
TEL.(847)380-3540.FAX:(978)913-3317
E-mail:sales@led-llc.com
For more energy efficient products, visit us online: www. led-llc.com or
www.remphos.com

FIG 2 Light efficient design.jpg

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)