Intranav IN5000 NODE with Wi-Fi User Manual

June 5, 2024
Intranav

User Manual
INTRANAV RTL

INTRANAV NODE (IN5000) INTRANAV NODE with Wi-Fi (IN5200)

Legal information

Warnings
This manual contains instructions that you must follow for your personal safety and avoid damage to property. The notes are highlighted by a warning triangle and are for your personal safety. Notes on sole property damage are without a warning triangle. Depending on the hazard level, the warning notes are shown in decreasing order as follows

DANGER: means that death or serious injury will occur if the appropriate precautions are not taken

WARNING: means that death or serious injury may occur if the appropriate precautions are not taken

CAUTION: means that slight physical injury may occur if the appropriate precautions are not taken

CAUTION: means that damage to property may occur if the appropriate precautions are not taken
If several hazard levels occur, the warning note for the highest level is always used. If a warning notice with a warning triangle warns against personal injury,  the same warning notice may also contain a warning against damage to property
Qualified personnel
The product/system associated with this documentation may only be handled by personnel qualified for the respective task, observing the documentation associated with the respective task, in particular, the safety and warning instructions contained therein. Due to their training and experience, qualified  personnel are capable of identifying risks and avoiding possible hazards when handling these products/systems

Intended use of INTRANAV products
Note the following

WARNING: INTRANAV products may only be used for the applications specified in the catalog and in the associated technical documentation. If third-party products and components are used, they must be recommended or approved by INTRANAV. The proper and safe operation of the products requires proper transport, storage, assembly, installation, commissioning, operation, and maintenance. The permissible ambient conditions must be observed. Instructions in the associated documentation must be observed

Brands
All designations marked with the property right note ® are registered trademarks of IntraNav GmbH. The other designations in this document may be trademarks whose use by third parties for their own purposes may infringe the rights of the owners

Overview

General
The INTRANAV NODE (IN5200), is a permanently installed antenna system for real-time indoor positioning. The NODE also called anchor, receives the ultra-wideband (UWB) signals of the TAGs and transmits them to the INTRANAV backend where they are processed to position signals

Scope of delivery and accessories

1  unit

INTRANAV RTLS NODE

Model: IN5X00

Accessories

1 unit

Universal holder for INTRANAV NODE

Power supply
The device can be operated with a voltage of 9 to 36 volts of direct current (DC) or via Power-Over-Ethernet (PoE).
The device complies with PoE class 802.3a

CAUTION: The supply voltage of the device must not exceed the following values: U <36V; I < 1.5A; P < 2

Fields of application
The device is designed to operate in an environment of 10°C to +50°C. For this reason, it is essential to ensure that the INTRANAV NODE (IN5200) is never used outdoors, as moisture or water can cause a short circuit. If you want to use INTRANAV RTLS NODEs outdoors, there is a special outdoor version available
Product dimension
Dimensions approx. 150 x 150 x 30 (mm) & weight approx. 180 (gr. )

Intranav IN5000 NODE with Wi Fi - Product dimension

Installation, commissioning, maintenance, and safety

General notes

  • Before installing the units, read carefully all the points listed in “3.
    Installation, commissioning, maintenance, and safety” to ensure proper installation and operation.

  • The devices can only be used in connection with the INTRANAV RTLS solution.

  • The correct structure, installation, and use of the localization system tools and clients are described in the corresponding manuals

Installation and operation

  • To achieve an optimal indoor location, the device should be mounted in such a way that there is a direct line of sight to the mobile location sensors (INTRANAV TAGs).
  • Before using the device, make sure that the device is not damaged and cannot be damaged during use.
  • Never cover the antenna with metallic or shielding objects.
  • The specified ambient temperatures of the devices must be maintained.
  • Do not power on the device until completely installed.
  • Ensure that all screws are securely and firmly screwed into the wall or bracket and can support the weight of the unit and wiring.
  • The housing of the device must never be crushed, pierced, or exposed to other mechanical forces.
  • The ambient temperature of the device must not exceed 50 °C. Avoid mounting locations with direct sunlight
  • The devices must be installed in accordance with the currently prevailing BG regulations “Electrical installations and equipment” (BGV A3). The devices must be mounted in such a way that they can be accessed at any time (opening the housing cover) to enable maintenance work to be carried out later.

Connection of cables and wires

  • When connecting the cables, always ensure that they are in perfect condition and not damaged.
  • Before putting the device into operation, check whether the cabling has been carried out correctly and whether it is connected to the network.
  • Only the cabling described in the manual, enclosed with the device or specified accordingly is to be used. IntraNav GmbH assumes no liability for  damage or impairment of functionality resulting from the use of other cables

Supply voltage

  • When the supply voltage is connected to the mains plug, the status LED flashes for a moment. The status LED is active when voltage is applied.
  • The device can be supplied with power via the Ethernet cable.
  • Do not supply the device with voltage via the mains input and PoE at the same time.
  • Check that the nominal voltage of the power supply corresponds to the values in the “Technical Data” section

CAUTION: The supply voltage of the device must not exceed the following values: U <36V; I < 1.5A; P < 2

Ethernet

  • When installing and connecting the Ethernet connection, the respective valid general conditions and their legal basis must be observed.
  • The Ethernet connection is connected to the Ethernet socket of the device. The cable must be assembled into the RJ45 plug before connecting it to the socket.
  • Powering the device with PoE (Power over Ethernet) requires an appropriate infrastructure such as PoE-Injector or PoE-Switch

Operating the device

  • Due to its design, the device is not intended for use in EX zones.
  • The intended operation of the system according to EN 60950-1 is only guaranteed when the housing cover is mounted (cooling, fire protection, radio interference suppression).
  • In case of emergency (e.g. damaged housing, ingress of liquid or foreign objects) immediately disconnect the power supply to the device.
  • The INTRANAV NODE detects mounting and position changes and goes into fault as soon as a shock or an improper change of the antenna is  detected by the integrated accelerometer
  • You must configure the INTRANAV NODE accordingly before configuring it on the INTRANAV.IO platform.
  • An INTRANAV NODE is ready for operation when the status LED is permanently lit.
  • The LED behavior is described as follows
Display Status LED Description
Lights green Supply voltage OK
Flashing green Connection to network and INTRANAV.IO backend successfully

established and available
Flashing red| Error: Accelerometer alarm
Glows red| Error: See error code INTRANAV.IO platform for more information
Flashing yellow| Warning: No network connection
Lights yellow| Warning: See error code INTRANAV.IO platform for more information
Glows blue| NODE faultless in operation
Flashing blue| NODE (Here-I-Am) mode

The signal behavior of the status LED may vary slightly depending on the firmware release and configuration. Please always refer to the INTRANAV.IO platform or current manual for the exact LED code.

Cleaning and maintenance

  • The device may only be installed and opened by appropriately trained personnel.
  • Repairs to the device must only be carried out by an authorized service center or trained key users.
  • Unauthorized opening and improper repairs can cause considerable the danger for the user
  • Unauthorized opening of the devices will result in the exclusion of warranty and liability of IntraNav GmbH.
  • Never use liquids, abrasive cleaners, alkaline cleaning agents, or sharp or abrasive tools to clean the housing

Technical data

Property Description
Radio procedures IEEE 802.15.4-2011 UWB (Ultra Wideband)
Frequency range UWB Channel 5 (6.4GHz)
Transmission power -34 dBm
Antenna Omnidirectional integrated antenna (max. 70m range)
Sensors 3-axis acceleration sensor Integrated temperature sensor Integrated

air pressure sensor
Supply voltage| Supply voltage by means of
–  Power-Over-Ethernet
– 9-36V DC
– USB-C
Ethernet| RJ45 Ethernet 100Mbit/s (full-duplex) DHCP Yes IEEE 802.3af, Class 0 (<2W)
Wi-Fi Version (IN5200)| Wi-Fi: 2412~2472MHz (2,4GHz) 19.60dBm(802.11b), 19.40dBm(802.11g), 18.60dBm(802.11n-HT20) For EU Power WPA & WPA2 Enterprise
Status LED| RGB LED
Protection class| IP 54
Dimensions| Approx. 150 x 150 x 30 mm
Weight| Approx. 180 g
Temperature range| 10°C … +50°C

Marking

Intranav IN5000 NODE with Wi Fi - Marking| Intranav IN5000 NODE with Wi Fi - Marking1
---|---

Wi-Fi Model (IN5200)
Non Wi-Fi Model (IN5000)

Approvals

EU Declaration of Conformity
The current EU Declaration of Conformity for this product is available on request or by e-mail to info@intranav.com.
The products described in this document meet the requirements of the following EU directives:

  • RoHS Directive 2011/65/EU
    Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment; Official Journal of the EU L174, 01/07/2011, p. 88-110

  • Radio Equipment Directive 2014/53/EU (RED, Radio Equipment Directive)
    Directive of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the Member States relating to the  provision of radio equipment on the market; Official Journal of the EU L153, 22/05/2014, p. 62-106

RoHS
RoHS directive (restriction of the use of certain hazardous substances)
The products described in these operating instructions meet the requirements of the EU Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Applied standard:

  • EN 50581

Technical documentation for the assessment of electrical and electronic equipment with regard to the restriction of hazardous substances

RED (Radio Equipment Directive)
Health and safety protection
The products described in this document meet the requirements of the tightened standards:
Art. 3 (1) a) Protection of health and safety

  • EN 62368-1Equipment for audio/video, information, and communication technology – Part
    1: Safety requirements

  • EN 62311Evaluation of electrical and electronic equipment with respect to limitations of human exposure to electromagnetic fields (0 Hz to 300 GHz)
    The products described in these operating instructions meet the requirements of Art. 3 (1) b) EMC Harmonized Standards:

  • ETSI EN 301 489-1Electromagnetic compatibility and Radio spectrum Matters (ERM) – ElectroMagnetic Compatibility (EMC) standard for radio  equipment and services Part
    1: Common technical requirements

  • ETSI EN 301 489-17Electromagnetic compatibility and Radio spectrum Matters (ERM) – ElectroMagnetic Compatibility (EMC) standard for radio  equipment and services Part 17: Specific conditions for Wideband Transmission Systems

  • ETSI EN 301 489-33Electromagnetic compatibility and Radio spectrum Matters (ERM) – ElectroMagnetic Compatibility (EMC) standard for radio  equipment and services Part 33: Specific conditions for Ultra Wide Band (UWB) equipment

  • EN 55011Industrial, scientific and medical equipment – Radio disturbance characteristics – Limits and methods of measurement

  • EN 55032 Class A, Class
    B Electromagnetic compatibility of multimedia equipment and devices – Emission requirements

  • EN 55035Electromagnetic compatibility of multimedia equipment – Immunity requirements

  • EN 61000-6-1Electromagnetic compatibility (EMC) – Part 6-1: Generic standards – Immunity for residential, commercial, and light-industrial environments

  • EN 61000-6-2Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for industrial environments

  • EN 61000-6-3Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission the standard for residential, commercial, and light- industrial environments

  • EN 61000-6-4Electromagnetic compatibility (EMC) – Part 6-4: Generic standards – Emission standard for industrial environment

Art. 3 (2) Efficient use of the radio spectrum

  • ETSI EN 300 328Broadband transmission systems
    – Data transmission equipment using 2,4 GHz ISM band and broadband modulation techniques – Harmonised EN covering essential requirements  under Article 3.2 of the EU Directive 2014/53/EU

  • ETSI EN 302 065-2
    Short Range Devices (SRD) using Ultra Wide Band (UWB) technology
    – Harmonised EN covering essential requirements under article 3.2 of the EU directive 2014/53/EU; Part 2: Requirements for Ultra Wide Band site surveillance

FCC
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,  there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television  reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Note
The operators should cease operation when harmful interference occurs to other users.

RF Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This equipment may only be operated indoors. Operation outdoors is in violation of 47  U.S.C. 301 and could subject the operator to serious legal penalties.
Note
The device may not be employed for the operation on board an aircraft, a ship, or a satellite is prohibited.
Note
The specified approvals are only valid if the corresponding symbol is printed on the device.

Recycling and disposal

The products are low-polluting, recyclable, and meet the requirements of the WEEE Directive 2012/19/EU for the disposal of waste electrical and electronic equipment.
Do not dispose of the products at public disposal points.
For environmentally friendly recycling and the disposal of your old device, please contact a certified disposal company for electronic waste or your IntraNav contact person.
Please note different country-specific regulations.

Troubleshooting

If a fault occurs, inspect the unit for the following faults and take appropriate action. If other undefined errors occur, contact IntraNav support. (www.IntraNav.com)
F: NODE Status LED is not lit.
A: Check the power supply
F: NODE Status LED lights red or yellow
A: Refer to the instructions for the error code
Q: NODE is not listed among the network devices in the platform.
A: Check the network connection and settings. Disconnect all wires and cables, wait 3 seconds, and reconnect the wires and cables.
Q: NODE is displayed on the platform in the wrong position.
A: Make sure that the NODE ID has not been swapped.
Q: Poor localization performance
A: Make sure that the NODEs are all set up in a square and that no objects are obstructing the line of sight to the TAGs.

INTRANAV RTLS NODE (IN5200) – Quick Guide
IntraNav GmbH
Frankfurter Str. 27
65760 Eschborn, Germany
Phone +49 6196-20471 80
Fax +49 6196-20471 89
Email: info@intranav.com
Internet: www.IntraNav.com
Company address: Frankfurt am Main (HRB 92924)
board of management
Andreas Radix
Ersan Günes
Gonzalo Ibarra

AT BE CY CZ DK EE Fl
FR DE EL HU IE IT LV
LT LU MT NL PL PT SK
SI ES SE UK BG RO HR

© Copyright 2020, IntraNav GmbH
This work is protected by copyright. Its use outside the narrow limits of copyright law is not permitted without the publisher’s consent and is punishable by law. This applies in particular to the reproduction, translation, microfilming, storage, and processing in electronic systems. All rights reserved.

Revisions
Initial English document version 1.0

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals