SCHLETTER FixZ-15 System Profile18 Bottom Instruction Manual
- June 3, 2024
- SCHLETTER
Table of Contents
FixZ-15 System Profile18 Bottom
Instruction Manual
Mounting Instructions
Required tools
Screwdriver with bits and socket wrench Bit T40
Bit hex-head 6-spanner
Socket wrench 8-spanner
Corresponding tools for the selected fasteners
Additional documentation
Structural analysis
Analysis print-out with a schematic diagram from the plant calculation
The Schletter tool kit comprises tools required for all standard systems.
Safety precautions
| Planning, mounting, and start-up of the solar plant must be performed
by qualified personnel only. Improper execution can result in damage to the
plant and to the building and can present a risk to people.
---|---
| Risk of falling! There is a risk of falling when working on the roof as
well as when ascending and descending the building. Accident prevention
regulations must be observed and appropriate safety equipment must be used. PV
mounting systems are not suitable as climbing aids or fall protection.
| Risk of injury! Objects falling from the roof can cause injury to
people. The danger area around the installation site must be
blocked off and persons in the vicinity must be warned of the risks.
| Risk of breakage! PV modules can be damaged if stepped upon.
****| Risk of electric shock! The mounting and maintenance of the PV modules
must be carried out by qualified personnel only. Please observe the safety
regulations issued by the solar module manufacturer!
Defining the area of installation
- Concentrate on the number of fasteners in the edge and corner zones.
- Further recommendations are pro- vided in the structural analysis.
Calculation formula:
e = min (x resp. y or 2 . h)
Mounting the fasteners
- Select the corresponding distance be- tween fasteners for the respective module. The exact dimensions are displayed in the Autokalkulator schematic diagram of your plant configuration.
- Please observe shading distances b between rows – also visible in the schematic diagram.
- The distance between fasteners c must comply with the structural analysis for fasteners – and is also displayed in the schematic diagram.
- Further recommendations are provided in the structural analysis (for fasteners).
**** The number of fasteners required is also dependent upon the properties of the roof – please verify details with the manufacturer!
Mounting the system rails
- Mount system rails on the fasteners – in our example:
Hook into the KlickTop attachment and secure with a 6-Lobe screw (T40).
Extending the lower system rail
- Position next rail.
- Mount the E connector from below.
- Tighten the pre-assembled 6-spanner screws.
**** Please make sure that sufficient space is left for the connector at rail joints.
Extending the upper system rail
- Position next rail.
- Mount the E* connector from below.
- Tighten pre-assembled hexagon socket head screws.
- Position the additional connector plate** against the inner side of the rail.
- Fasten each with a self-drilling screw (8-spanner) per rail end.
**** Please make sure that sufficient space is left for the connector at rail joints.
Mounting the module
- Position the first module flush with the end of the rail, then observe the indentation distance d (c.f. Autokalkulator schematic diagram and information issued by the manufacturer)
- Fasten the module with two end clamps – in our example: click in the Rapid end clamps and tighten the 6-Lobe screws (T40).
- Connect the module cables as required.
- Position further modules and secure each between the modules with two middle clamps.
- Secure the last module of the row with two end clamps.
Mounting Instructions FixZ-15 | 2015.01 V.004
Schletter Solar GmbH – Alustraße 1 – 83527 Kirchdorf
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>