INSTALLATION INSTRUCTIONS FOR 1 AMP SPEED CONTROLLERS
Speed controller for single phase voltage controllable motors
1 x 1 AMP CONTROLLER WILL OPERATE THE FOLLOWING:
AIRIUS
MODEL| 10| 15| 25| 45/PS-4| 45/PS-2|
50/PS-4| 60/PS-4
---|---|---|---|---|---|---|---
NO. OF
UNITS| 13| 10| 5| 4| 1| 2| 1
PLEASE CONTACT SIRIUS FOR RECOMMENDED QUANTITY OF FANS PER CONTROLLER FOR YOUR UNIQUE APPLICATION
Technical Data
Voltage: 230Vac – 50/60Hz
MAX AMPS FUSE
STR-1-10L10 1.0 FT-1.25A
Enclosure: Plastic R-ABS, UL94-V0, grey RAL 7035 or sheet steel (RAL 7032,
polyester powder coating).
Recommended prim. Fuse: ca 1,5 extra.
Max ambient temperature: 35°C
These transformer speed controllers are based on the principle of voltage
control with auto-transformers.
They are applicable to voltage-controllable motors (230V – 50/60Hz) to control
the speed (of fans, pumps, etc.). When choosing a controller it is important
to know the current intensity consumption on the taps.
Mounting
The controllers are to be mounted on a smooth surface. Connect voltage supply, motor(s), and earth as shown in the scheme with cables of the proper diameter. On the side of the main, a safety switch with recommend pre-fuses has to be installed.
Transport and Stock Keeping
Avoid shocks and extreme conditions, stock in original packaging.
Warranty
Two years from delivery date against defects in manufacturing. Any
modifications or alterations to the product relieve the manufacturer of all
responsibility.
The manufacturer bears no responsibility for any misprints or mistakes in this
data, and modifications or improvements to the product can be made at any time
after date of publication.
Maintenance
In normal conditions the controllers are maintenance-free. If soiled clean with dry or dampish cloth. In case of heavy pollution clean with a non- aggressive product. In these circumstances, the controller should be disconnected from the mains. Pay attention that no fluids enter the controller. Only reconnect the controller to the mains when it is completely dry.
Motor Protection
It is always recommended to install a proper motor protection device.
All works may only be carried out by skilled personnel following the local
regulations and AFTER the controller is completely separated from the mains.
Replace fuse only with the same type and rating.
According to the low voltage directive: 2006/95/EC/The EMC directive:
2004/108/EC
DIMENSIONS
SPEED CONTROLLER COMPONENTS
WIRING DIAGRAM
PLEASE NOTE: THIS CONTROLLER MUST BE EARTHED