WARRANTY

The Gentec-EO BA Optical Attenuators carry a one-year warranty (from date of shipment) against material and/or workmanship defects, when used under normal operating conditions. The warranty does not cover damages related to battery leakage or misuse.
Gentec-EO Inc. will repair or replace, at Gentec-EO Inc.’s option, any accessories for beam diagnostics that prove to be defective during the warranty period, except in the case of product misuse.
Any attempt by an unauthorized person to alter or repair the product voids the warranty.
The manufacturer is not liable for consequential damages of any kind.
In case of malfunction, contact your local Gentec-EO distributor or nearest Gentec-EO Inc. office to obtain a return authorization number. The material should be returned to:

Gentec Electro-Optics, Inc.
445, St-Jean-Baptiste, Office 160
Quebec, QC
Canada, G2E 5N7
Tel: 418-651-8003
Fax: 418-651-1174
E-mail: service@gentec-eo.com
Website: www.gentec-eo.com

CLAIMS
To obtain warranty service, contact your nearest Gentec-EO agent or send the product, with a description of the problem, and prepaid transportation and insurance, to the nearest Gentec-EO agent. Gentec-EO Inc. assumes no risk for damage during transit. Gentec-EO Inc. will, at its option, repair or replace the defective product free of charge or refund your purchase price. However, if Gentec-EO Inc. determines that the failure is caused by misuse, alterations, accident or abnormal conditions of operation or handling, it would therefore not be covered by the warranty.

SAFETY INFORMATION

Do not use the BA Optical Attenuators if they look damaged, or if you suspect that the BA Optical Attenuators are not operating properly.

Caution:
Changes or modifications not expressly approved in writing by Gentec-EO Inc. may void the user’s authority to operate this equipment.

SYMBOLS
The following international symbols are used in this manual:

Refer to the manual for specific Warning or Caution information to avoid any damage to the product.

INTRODUCTION

The Gentec-EO Optical Attenuator BA Series includes four optical attenuators: three models with 16-mm aperture for lower powers and a 1-kW model with a 32-mm aperture. The Optical Attenuator BA Series is expressly designed to be used simultaneously with a BEAMAGE beam profiler. For further information about the BEAMAGE Profiler, refer to the corresponding manual on gentec- eo.com/resources/download-center.

Model Maximum Power
BA16-60S 60 W
BA16K-150S-H5-D0 150 W
BA16K-500F-H9-D0 500 W
BA32-1KW 1000 W

gentec-EO BA Series BA16-60S Optical Attenuators-1

For Gentec-EO’s nearest office contact information, see p. ii, Contacting Gentec Electro-Optics Inc.

WARNINGS AND DISCLAIMER

In no event shall Gentec-EO or any of its affiliates be liable for any indirect, special, incidental or consequential injury to persons or damage to property caused by the use of any of our products, by purchasing from Gentec- EO or any of its affiliates, you hereby indicate that you understand and agree to the following:

Disclaimer

I am fully responsible for the safe application and use of this product and agreed to such by completing the sales process.
I will not use a laser device without wearing approved laser safety goggles designed for such purpose.
I am aware and responsible of safely dealing with any back reflections. I will not use the product in violation of any local, state or federal law, and I understand that it is my responsibility to know and abide by those laws relating to the ownership and use of the product in my jurisdiction.

Attenuator temperature while in operation
During usage, the attenuator (especially the beam dump) can become hot enough to cause burns.

Warning Be careful not to exceed the maximum levels and densities stated in the specifications.

BA16 OPTICAL ATTENUATOR SERIES

POWER DETECTOR

The BA16K-150S-H5-D0 and BA16K-500F-H9-D0 come with a built-in UP power detector which can be used via a DB-15 connector. The power detector included with your attenuator model is specified at section 3.2. For further information about the UP power detector itself, refer to the UP Manual (available at genteceo.com/resources/download-center ).

SPECIFICATIONS

The following specifications are based on an operating temperature of 15ºC to 28ºC (59 to 82ºF) and a relative humidity not exceeding 80%. Attenuators must be stored in an environment between 10ºC to 65ºC and a relative humidity not exceeding 90%.

Gentec-EO BA16-60S BA16K-150S-H5-D0 BA16K-500F-H9-D0
  Measurement Capability
Spectral Range 200 nm – 2100 nm

Spectral Range with BEAMAGE

Camera

| 350 nm – 1150 nm
Average Attenuation 1| 1700 @ 1.064 µm
Integrated Power Meter| None| UP19K-15S-H5-D0| UP19K-110F-H9-D0
Maximum Power| 60 W| 150 W| 500 W
Aperture Diameter| 16 mm
Maximum Beam Diameter| 16 mm
Optical Wedges Material| UV Fused Silica (uncoated)
Sampled Beam Lateral Shift| 21mm
Sampled Beam Deviation| 90°
Residual Beam Deviation| 5.6°
CW Laser Damage Thresholds on the Optical Wedge

1.064 µm, CW

| Average Power Density

10 MW/cm2

Pulsed Laser Damage Thresholds on the Optical Wedge

1.064 µm, 7 ns, 10 Hz

| Max. Energy Density

10 J/cm2

Max. Average Power Density on the Power Meter

1.064 µm, 10W CW

10.6 µm, 10W CW

|

45 kW/cm2

14 kW/cm2

|

36 kW/cm2

11 kW/cm2

|

45 kW/cm2

14 kW/cm2

Pulsed Laser Damage Thresholds

of the Power Meter 2

| Max. Energy Density| Peak Power Density
1.064 µm, 360 µs, 5 Hz

1.064 µm, 7 ns, 10 Hz 532 nm, 7 ns, 10 Hz 266 nm, 7 ns, 10 Hz

| H5 : 5 J/cm2 H9 : 9 J/cm2

1.0 J/cm2

0.6 J/cm2

0.3 J/cm2

| H5 : 14 kW/cm2 H9 : 25 kW/cm2

143 MW/cm2

86 MW/cm2

43 MW/cm2

 | Physical Characteristics
Dimensions| 81H x 47W x 45D

mm

| 86H x 54W x 50D mm| 126H x 54W x 54D mm
Fan Input Voltage| NA| NA| 12 VDC

For 0° angle of incidence of the input aperture.
Attenuation of 24 @ 1.064 μm assuming a random polarization at 0° angle of incidence of the input aperture.

Weight 0.26kg 0.37kg 0.46kg
Mounting ¼ – 20 (imperial) threaded holes / 30mm cage system
Input & Output Aperture Threading SM1
Product Number 203791 203792 203793

The attenuation varies with the wavelength. The graph below presents the attenuation as a function of the wavelength considering an angle of incidence of 0° with the input aperture.

gentec-EO BA Series BA16-60S Optical Attenuators-2

BEAM PATH DETAILS

gentec-EO BA Series BA16-60S Optical Attenuators-3 gentec-EO BA Series BA16-60S Optical
Attenuators-4

OPERATING INSTRUCTIONS

Storage
In order to ensure a long lifetime of accurate measurements, it is recommended that attenuators be held within the following ambient conditions:

  • Storage environment temperature: 10 to 60°C, RH < 90%
  • Operating environment temperature: 15 to 28ºC, RH < 80%.

It is possible to store and operate your Optical Attenuator beyond this range. For any specific requirements, please contact your local Gentec-EO representative.

General operation with BEAMAGE beam profiling camera
For the BA16K-500F-H9-D0 only, connect the fan to the included power supply to ensure an adequate cooling. Once appropriate cooling is achieved, the Attenuator is ready to be aligned in the intended optical set-up.

  1. Remove the protective covers from the Attenuator and power detector.
  2. Using the supplied coupler, install the BEAMAGE camera on the attenuator’s sampled beam aperture. Use the locking rings to secure the BEAMAGE on the coupler and the coupler to the Attenuator.
  3. Download and install the software PC-BEAMAGE (available at gentec-eo.com).
  4. Connect the BEAMAGE to the computer. For further information about PC-BEAMAGE, refer to the corresponding manual on gentec-eo.com/resources/download-center.
  5. Align the Attenuator in the optical set-up using a safe “low-power” laser by centering the beam into the power detector and in the BEAMAGE. In order to ensure an optimum, polarization-independent attenuation coefficient, the laser beam should ideally be perfectly aligned and centered within the Attenuator’s input aperture and in the BEAMAGE.

Warning
Never touch directly the optics or the absorbing surface of the beam dump/power detector.

In the case of a joint use of a BA16 and a BEAMAGE camera in order to profile a high-power beam, an additional neutral density filter to the camera may be necessary. If an additional ND filter is necessary, make sure to not exceed the maximum average power density of the power meter. Refer to the section 3.2 or the UP User Manual (available at gentec-eo.com/resources/download- center) for additional information and specifications about the power meter.

Calibration procedure to use the integrated power detector (models BA16K- 150S-H5-D0 and BA16K-500F-H9-D0 only)
In order to use the integrated power detector for input beam power live monitoring, you need to determine the attenuation factor by using the following steps:

  1. Measure the power of your laser beam before the optical aperture of the Optical Attenuator.
  2. Measure the power of your laser beam with the integrated power detector (after the second wedge).
  3. Divide the power obtained in 1 by the power obtained in 2 to calculate the attenuation factor “A”.
  4. Enter the calculated factor “A” in the PC-Gentec-EO software or in your Maestro display as a Multiplier to get a live measurement of the input beam power.

Important
The laser beam alignment and power must be steady for the steps 1 and 2.

Note: The attenuation factor “A” between the input beam and the integrated power detector depend on the polarization and the alignment of your laser beam. The attenuation factor “A” should be recalculated (steps 1 to 4) after any alignment modification.

Compatibility
The attenuators of the BA series are compatible with many Gentec-EO detectors.
In addition, the BA series attenuators can easily be used with any detector or device threaded according to SM1 standard and specifically with the following Gentec-EO detectors:

  • PRONTO-Si with the threaded adaptor accessory
  • Photodetectors PH and PE series
  • Thermal power detector XLP12 and UP10 series

For more information about compatibility, please contact your local Gentec-EO representative.

Damage to the optical absorber material
Damage to the optical absorber material is usually caused by exceeding the manufacturer’s specifications, such as:

  • Incident Average Power Density
  • Incident Pulse Energy Density

Refer to the specification pages for the Optical Attenuator BA Series. Damage may also be caused if the absorber surface and/or optics are contaminated. A slight discoloration of the coating does not affect the absorption.

In any case, the beam’s incident area should not be less than 10% of the beam dump’s aperture. Please contact Gentec-EO to make measurements with such smaller beams.
In the event of significant damage to the coating, the UP sensors or the beam dump can be recoated. Contact your local Gentec-EO representative for information on repair and recalibration. See p. ii Contacting Gentec Electro- Optics Inc

BA32 OPTICAL ATTENUATOR SERIES

POWER DETECTOR
The BA32 series can be used with a UP power detector (optional). The optional power detectors compatible with your attenuator model is specified at section 4.3. For further information about the UP power detector itself, refer to the UP Manual (available at gentec-eo.com/resources/download-center ).

COOLING WATER
The fluid used to cool the Optical Attenuators of the BA32 series must be clean water.

Water fittings and tubing:

  • The BA32 are equipped with 10mm (OD) push-to-connect fittings.
  • It must be used with plastic pressure tube systems (like PE tubes).
    The fittings are not compatible with copper or stainless steel tubes.

Water quality:

  • The BA32 cooling fluid must be water, do not use glycol or other additives.

  • Use filtered (< 50μm) water to avoid any residue.
    Gentec-EO can provide an external water filter if water quality is an issue (202290 Metric or 202984 Imperial). If you require an external water filter, please contact your local Gentec-EO representative.
    Note: The water filter provided by Gentec-EO is a chemical-resistant filter. However, it is not compatible with mineral acids.

  • The resistivity of the water must be over 100 kOhm-cm.

  • Distilled water can be used, but it is not recommended to use highly deionized ultra-pure water because the water cavity is not completely inert.

  • If an algaecide must be used in the chiller, we recommended Optishield Plus or equivalent.

  • If chloride is present in the system, the concentration should not exceed 25 PPM and the PH maintained between 6.0 to 8.0. (Low PH will remove the protective oxide layer)

Water temperature:

  • The cooling water can be between 15 and 25°C but must always remains above the dew point.
  • The temperature should be regulated with a chiller or a re-circulator.

Water flow rate:

  • The water flow rate should be monitored.
  • NOTE: the water pressure at the BA32 input must never exceed 60 psi / 413 kPa.

Note: All these parameters should remain in the range stated in the specifications.

SPECIFICATIONS
The following specifications are based on an operating temperature of 15ºC to 28ºC (59 to 82ºF) and a relative humidity not exceeding 80%. Attenuators must be stored in an environment between 10ºC to 65ºC and a relative humidity not exceeding 90%.

Gentec-EO BA32-1KW
  Measurement Capability
Spectral Range 200 nm – 2100 nm
Spectral Range with BEAMAGE Camera 350 nm – 1150 nm
Typical Average Attenuation 3 1900 @ 1.064 µm
Integrated Power Meter (Optional) Compatible with UP55N/M series
Maximum Power 1 kW
Aperture Diameter 32 mm
Maximum Beam Diameter 32 mm
Optical Wedges Material UV Fused Silica (uncoated)
Sampled Beam Lateral Shift 4.5 mm
Sampled Beam Deviation 90°
Residual Beam 1 & 2 Deviation 3.6°@ 1.064 µm

CW Laser Damage Thresholds on the Optical Wedge

1.064 µm, CW

| Average Power Density

10 MW/cm2

Pulsed Laser Damage Thresholds on the Optical Wedge

1.064 µm, 7 ns, 10 Hz

| Max. Energy Density

10 J/cm2

Liquid Coolant| Water
Cooling Flow Rate| 1 to 2 L/min
Coolant Pressure Drop| < 5 PSI
Heat Load| < 100 W
Coolant temperature| 15 – 25 °C
Coolant Maximum Input Pressure| 60 PSI
 | Physical Characteristics
Dimensions 4| 145(H)x250(W)x132(D) mm
Weight| 5.5kg
Mounting| M6 (metric) threaded holes
Optical Apertures Threading| SM2
Product Number| 205319

Specifications are subject to change without notice

Considering 0° AOI referred to the input aperture.
Overall dimensions and weight while using BEAMAGE and/or power detector will be different.

The attenuation varies with the wavelength. The graph below presents the attenuation as a function of the wavelength considering an angle of incidence of 0° with the input aperture.

gentec-EO BA Series BA16-60S Optical Attenuators-5

BEAM PATH DETAILS

Typical power values @1070nm (% of incident beam)

Residual Beam 1| 92%
Between the 2 wedges| 2 x 4% = 8%
Residual Beam 2| 2 x 3.7% = 7.4%
Sampled Beam| 0.1%

gentec-EO BA Series BA16-60S Optical Attenuators-6

Optical path length

Input to Sampled Beam (without

accessorie)

| 263 mm
Input to Residual Beam 1| 100 mm
Input to Residual Beam 2| 257 mm
Sampled Beam to BEAMAGE-4M- FOCUS with BA32-FOCUS

mounting kit

| 123 mm
Sampled Beam to BEAMAGE-4M

with BA32-B3 mounting kit

| 113 mm

OPERATING INSTRUCTIONS

Storage
In order to ensure a long lifetime of accurate measurements, it is recommended that attenuators be held within the following ambient conditions:

  • Storage environment temperature: 10 to 60°C, RH < 90%
  • Operating environment temperature: 15 to 28ºC, RH < 80%.

It is possible to store and operate your Optical Attenuator beyond this range. For any specific requirements, please contact your local Gentec-EO representative.
The protective covers should always remain on your BA32 Optical Attenuator while not using.

General operation with BEAMAGE beam profiling camera
Once appropriate cooling is achieved, the Attenuator is ready to be aligned in the intended optical set-up.

  1. Connect your BA32 Optical Attenuator to the cooling circuit.
  2. Ensure your BA32 Optical Attenuator is cooled adequately (following the specifications in the sections 4.2 and 4.3).
  3. Remove the protective cover from the Residual Beam 2 aperture.
  4. Install your UP55 power detector with the power detector mounting kit BA32-UP55 (optional).
  5. Remove the protective cover from the Sampled Beam aperture.
  6. Using the mounting kit provided for your BEAMAGE (optional mounting kit BA32-FOCUS / BA32-B3), install the BEAMAGE camera on the attenuator’s Sampled Beam aperture. Use the locking rings to secure the BEAMAGE on the coupler and the coupler to the Attenuator.
  7. Download and install the software PC-BEAMAGE (available at gentec-eo.com).
  8. Connect the BEAMAGE to the computer. For further information about PC-BEAMAGE, refer to the corresponding manual on gentec-eo.com/resources/download-center.
  9. Remove the protective cover from the Residual Beam 1 aperture.
  10. Align the BA32 Attenuator in the optical set-up using a safe “low-power” laser by centering both: the beam on the target of the input protective cover and in the BEAMAGE. In order to ensure an optimum, polarization-independent attenuation coefficient, the laser beam should ideally be perfectly aligned and centered within the Attenuator’s input aperture and in the BEAMAGE.
  11. Remove all the protective covers prior to use the Optical Attenuator BA32.

Warning
Never touch directly the optics or the absorbing surface of the beam dump/power detector.

In the case of a joint use of a BA32 and a BEAMAGE camera in order to profile a high-power beam, an additional neutral density filter to the camera may be necessary. If an additional ND filter is necessary, make sure to not exceed the maximum average power density of the power meter. Refer to the section 4.3 or the UP User Manual (available at gentec-eo.com/resources/download- center) for additional information and specifications about the power meter.

Calibration procedure to use the integrated power detector
In order to use the integrated power detector for input beam power live monitoring, you need to determine the attenuation factor by using the following steps:

  1. Measure the power of your laser beam before the input of the BA32 Optical Attenuator.
  2. Measure the power of your laser beam with the integrated power detector (at the Residual Beam 2 output).
  3. Divide the power obtained in 1 by the power obtained in 2 to calculate the attenuation factor “A”.
  4. Enter the calculated factor “A” in the PC-Gentec-EO software or in your Maestro display as a Multiplier to get a live measurement of the input beam power.

Important
The laser beam alignment and power must be steady for the steps 1 and 2.
Note: The attenuation factor “A” between the input beam and the integrated power detector depend on the polarization and the alignment of your laser beam. The attenuation factor “A” should be recalculated (steps 1 to 4) after any alignment modification.

Compatibility
The attenuators of the BA32 series are compatible with many Gentec-EO detectors. For more information about compatibility, please contact your local Gentec-EO representative.
Damage to the optical absorber material
Damage to the optical absorber material is usually caused by exceeding the manufacturer’s specifications, such as:

  • Incident Average Power Density
  • Incident Pulse Energy Density

Refer to the specification pages for the Optical Attenuator BA32 Series. Damage may also be caused if the absorber surface and/or optics are contaminated. A slight discoloration of the coating does not affect the absorption of the power detector.
In any case, the beam’s incident area should not be less than 10% of the beam dump’s aperture. Please contact Gentec-EO to make measurements with such smaller beams.

In the event of significant damage to the coating, the UP sensors or the beam dump can be recoated. Contact your local Gentec-EO representative for information on repair and recalibration. See p. ii Contacting Gentec Electro- Optics Inc

ANNEXE A: WEEE DIRECTIVE
Refer to the UP User Manual if necessary (available at www.gentec-eo.com) for the power detector declaration of conformity.
WEEE compliance
These products comply with the European Directive 2012/19/EU – WEEE

Recycling and separation procedure for WEEE directive 2012/19/EU
This section is used by the recycling center when the detector reaches its end of life. Breaking the calibration seal or opening the monitor will void the detector warranty.
The complete accessory package can contain:

  • 1 Accessory
  • 1 Detector with DB-15.
  • 1 Instruction manual
  • 1 Calibration certificate

Separation

  • Paper: Certificates (if applicable)
  • Wires: Detector cable. (if applicable)
  • Printed circuit board: inside the Detector (for -MT, -MA, -BT and -CP version only) or DB-15, no need to separate (less than 10 cm2). (if applicable)
  • Glass: Optical component. (if applicable)
  • Aluminum: Accessory housing. (if applicable)

gentec-EO BA Series BA16-60S Optical Attenuators-7

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

gentec-EO User Manuals

Related Manuals