Whynter ARC-101CW Coolsize 10000 BTU Compact Portable Air Conditioner
DISPOSAL INFORMATION
Please follow the instructions provided in this user guide to obtain the very best performance from your portable air conditioner and take full advantage of the many features your portable air condi-tioner offers you. We trust that your Whynter air conditioner will provide the performance and relia-bility that we stand for.This symbol on the product or its packaging indicates that the appliance cannot be treated as nor-mal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment. Fur-ther information about the recycling of this product can be obtained from your local municipal authority.
SAFETY PRECAUTIONS
WARNING
- Do not under any circumstances cut or remove the third ground prong from the power cord
- Make sure this unit is connected to a correctly grounded power supply outlet.
- Do not use an extension cord or power strip
- The power cord is UL listed. It has a built-in L.C.D.I leakage, current, detection, interruption) circuit breaker for added safety.
- If the power supply is interrupted, press the reset button to reconnect the unit to power source
- It is recommended to use a separate circuit that its size should be 15 Amps for the air conditioner
- Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air condition-er
- To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other applianc-es
- Do not repair, disassemble and/or modify the unit by yourself
- Always turn off the portable air conditioner when cleaning the air filter, and transporting
- Do not turn this unit on and off by plugging and unplugging.
- Always use the ON/OFF switch
- Transport the unit in an upright position only, or leave it in an upright position for at least 4 hours before first use
- Ensure curtains or other objects are not obstructing the air inlet filters
- Do not bend or crush the exhaust hose while in use
- Always allow at least 20 of clearance around the unit for ventilation.
- Do not use this unit inside closets, cabi-nets and/or cramped spaces between furniture
- This unit is optimized to operate in an ambient temperature of 64°F – 90°F
- This unit must be installed in an area protected from the element, such as wind, rain, water spray or drips
- The unit should not be located next to ovens, grills or other sources of high heat
- Always place the unit on even and hard and level surface
- Do not sit or place objects on the unit
- Do not allow children to climb, stand or hang on the appliance.
- The air conditioner could tip over and get dam-aged and/or seriously injure somebody
- Keep fingers out of the air intakes and air outlets
- The appliance is an electrical appliance.
- To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water.
- Do not use it in outdoors or in wet condi-tions
- When positioning or moving the appliance, ensure it is not turned upside down or greater than 45° or more off level.
- This appliance is designed for household, non commercial use only.
- Any other use will void the warranty.
- Do not plug into the power outlet before set up is completed.
- Do not operate this unit without the air filter.
- Do not use harsh chemicals to clean the filters.
- Dry thoroughly before inserting the filter into the unit.
- Do not add extra length to the exhaust hose by more than a total length of 9.
- This will reduce the cooling effi-ciency of the portable air conditioner.
- At the end of each season, all water must be drained from the unit and filter must be cleaned before storage.
INTRODUCTION / TECHNICAL DATA
HOW IT WORKS
The Whynter compact CFC-free, lead-free, and energy efficient 10,000 BTU portable air conditioner, helps you stay cool while working with better environmental standards and reducing ener-gy consumption. This compact portable air conditioner, specially designed to be mobile can be easily setup in almost any indoor location and is most commonly used in data closets / server rooms, bedrooms, classrooms and garages / workshops. This Whynter ARC- 101CW compact portable air conditioner features an ECO FRIENDLY CFC free GREEN R-410A refrigerant and lead-free RoHS compliant components.
TECHNICAL DATA
Model| ARC-101CW
Operational Modes| Cool, Fan or Dehumidifier
Cooling Capacity| 10000 BTU
Dehumidifying Capacity| 70 Pts / day
Fan Speed| 3 Fan Speeds
Filters| Activated carbon filter and washable pre-filter
Thermostat Control Range| 61° – 89°F
Timer| 24 hour programmable timer
Noise Level| < 55 dBA
Refrigerant| R-410A
Air Flow at high speed| 264 m3/h / 145 CFM
Maximum Power Consumption| 1000W / 9.4A
Power Supply| 115 V / 60Hz
CEER | EER| 6.18 | 7.35
Unit Dimensions| 17W x 14 D x 28 H
Package Dimensions| 23.6 W x 16 D x 30.7 H
Net Weight| 58 lbs
Gross Weight| 69 lbs
Exhaust Hose| 5.5 diameter
Hose Connectors| 5.5 diameter with 5.0 diameter reducer
Fixture and Window Kit| 5.0 diameter
Window Kit| 6.5 W x 20 (min)/ 46 maxL
PARTS IDENTIFICATION
ACCESSORY IMAGE | ACCESSORY DESCRIPTION | QUANTITY |
---|---|---|
**** | **** |
Exhaust Hose
| ****
1 piece
|
Window slider kit
| ****
1 set
|
Fixture
| ****
1 piece
|
Screws
| ****
4 pieces
|
Hose Connector to Window Kit with tab cut-outs
| ****
1 piece
|
Slide Locking Hose Connector to unit
| ****
1 piece
| Cover| 1 piece
| ****
Remote control
| ****
1 piece
|
Storage Cover
| ****
1 piece
Operating Conditions
Mode | Room Temperature |
---|---|
Cool | Higher than 64°F |
Dehumidify | Higher than 60°F |
Leakage Current Detection and Interruption (LCDI)
Your portable air conditioner is supplied with a Leakage-Current Detection and Interruption (LCDI) plug. This plug reduces the risk of fire due to arcing faults in the power supply cord. Please follow the instructions below to ensure that LCDI plug works properly.
- Plug the power cord to a grounded wall outlet. Do not plug to a power strip or extension cord.
- Press the TEST button on the plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and the unit comes on, please contact technical support.
- Press the RESET button to start the air conditioner.
- Do NOT use the TEST and RESET buttons to turn the air conditioner on and off.
CONTROL PANEL
Indication symbols on LCD
Cooling mode
High Fan speed
Display set temperature
Dehumidifying mode
Medium Fan speed
Stop display
Fan only mode
Low Fan speed
Display timer setting: Auto Switch On/Off
Power Button
Press to turn the air conditioner on and off.
Mode Control
Press to change mode Controls the 3 function modes COOL, FAN, and DEHUMIDIFY.
Fan Speed Button
Press to change fan speed Controls the 3 fan speeds. HIGH, MEDIUM, and LOW. The fan speed indicator lights illuminates to show the set fan speed.
Timer / Temp Set Control
Adjusts set temperature (1°C/ 2°F increments) or timer hours (0 – 24 hours).This unit is capable of displaying set tempera-ture in Fahrenheit or in Celsius. To convert from one to the other, press +and – holdthe and buttons for 3 seconds.
LCD Display
In Cool mode shows set temperature in °C or °F. In DEHUMIDIFY and FAN only modes: showsroom temperature.
Timer Button
Press to program Timer Delayed Switch ON or OFF function.
Stop display
Condensed water may accumulate in the unit. If the internal tank becomes full, the Stop display will come on and the unit will not operate until the unit has been drained.
INSTALLATION
WARNING
NEVER OPERATE THE AIR CONDITIONE R WITHOUT THE AIR FILTER Your Whynter
portable air conditioner is equipped with a washable pre-filter and an
Activated Carbon Filter. The washable pre-filter removes large particles such
as dust, pet hair and dander. The Activated Carbon filter is designed to
remove smoke and other odors. It is recommended you replace the Activated
Carbon filter every 2-3 months or as needed. Follow the steps below to install
the filters.
Pull out the washable prefilter.
Attach the activated carbon filter into the air intake frame
Once the activated carbon filter is secured, reinstall the washable pre-filter frame into the unit.
WATER DRAINAGE
The dehumidifying capacity of this unit is 70 pints per day. The patented self-evaporating function of the unit fully exhausts all condensation automatically in most environments when humidity is less than 70%. Areas with more than 70% humidity, the self-evaporating function can still exhaust about 98% of the moisture and the remaining 2% of moisture will be collected in the water tank of the air conditioner. When there is excess water condensation inside the unit, the air conditioner stops running and illuminates the Stop light. This Stop light indicates that the water condensation needs to be drained using the following procedures
Manual drainage
- Turn off the unit.
- Carefully roll the unit to a drain location or position a flat container, dish or optional drain bucket accessory soldseparately under the drain area of the lower drain port.
- Remove the drain cover and rubber plug and the condensed water will drain out automatically.
- Once all the condensed water is drained, replace the drain rubber plug and cover into the drain firmly.
- Continuous Gravity Drainage OptionThis option is recommended if uninterrupted operation is desired.
- Remove the drain plug cover and rubber plug from the upper drain port.
- Install the drain hose (sold separately) through the drain cover.
- Thread the drain cover onto the upper drain port.
- Place the open end of the drain hose downward to an area appropriate for draining.
WARNING
The hose must be directed downward from the upper drain port to allow the
condensed water to flow with gravity. Please contact
support@whynter.com for retail sales information
or visit whynter.com for a list of optionalaccessories.
LOCATION
The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects. Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air conditioning.
EXHAUST HOSE INSTALLATION
When using the air conditioner, the hot air from the exhaust hose must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in dehumidifying or fan-only mode, installation of the exhaust hose is optional.
Expand each end of the exhaust hose about 6. Install the hose connectors onto the exhaust hose by turning clockwise. Slide the slide locking hose connector onto the rear of the unit.Only extend the both hoses to the necessary length. We do not recommend extending more than 9′ long. If you are interested in purchasing an additional 5’ exhaust hose, please contact support@whynter.com for retail sales information.
WINDOW KIT INSTALLATION
The window kit has been designed to fit most standard vertical and horizontal windows.However, it may be necessary to modify the installation procedures to accommodate your window.
NOTE
If your window opening is smaller than the minimum length of the window slider
kit, the window slider kit can be cut to fit the window opening. Never cut
into the exhaust hose cut-out on the window slider kit. If your window
opening is larger than the maximum length of the window slider kit, additional
material will be needed to cover the open space such as, Plexiglas, PVC
plastic, ply wood, etc. Alternately, an additional window slider kit can be
purchased to be used in combination with the included kit. When using the
window slider kit on a window or sliding door, additional security measures
may be needed.
- Open the window approximately 5.
- Adjust the length of the window slider to the same length and width of the opening of the window.
- Cut the window slider if necessary to fit the length of your window.
- Insert the fixture through the back grooved side of the window slider hose cut out.
- Line up the fixture with the 4 screw holes and tighten the fixture with 4 screws from the front side of the slider panel.
- Fit the window slider kit into the window opening and close the window to secure the window slider kit.
- For 5. long term installation, you may screw the window kit into your window frame.
- Move the unit close to the window, extend the hose to the necessary length, keeping it as short and as straight as possible and attach the other end of the hose to the window slider kit.
- Align the tab cut-outs of the hose connector to the tabs on the fixture and snap the hose connector to the window slider kit.
OPERATION INSTRUCTIONS
BEFORE USING YOUR APPLIANCE
Remove the exterior and interior packaging.Before connecting the appliance to a power source and operating, let the unit stand upright for a minimum of 4hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation.
SWITCHING ON/OFF THE AIR CONDITIONER
The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF button on the remote control.
COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the Mode Control until the Cooling indicator light comes on. When the cooling mode is set, the compressor will start in ap- proximately 3 minutes. In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the hot air. The temperature setting range of this air conditioner is from 61°F / 16°C to 89°F / 32°C. To set the temperature, press the + or – buttons. This air conditioner has a 5°F temperature cushion which if the set temperature is within 5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the com-pressor of the air conditioner. To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the 3 fan speeds is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings.
DEHUMIDIFYING ONLY MODE
In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to LOW. To activate this function mode, press the Mode Control until the Dehumidifying indicator light comes on. Please note that when switching functions, there will be an approximate 3 minute transition time. In dehumidifying mode, the exhaust hose does not need to be vented. If the exhaust hose is vented, the room will be cooled as it dehumidifies. To prevent cooling, remove the exhaust hose from the window kit and allow the warm air from the rear to be re-circulated into the room. If room temperature is higher than 77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan speed is set at Low.
NOTE
When using Dehumidifying mode, venting the exhaust hose to the outside is not
required. If vented, the warm air is exhausted to the outside and cooling
within the room may occur. Additionally, if the exhaust hose is not vented,
the unit may require more frequent draining. The air conditioner does not have
a humidistat in which a specific humidity level can be set.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the MODE button until the Fan indicator light comes on. In this function mode, the temperature cannot be set. Subsequently, set the desired fan speed by pressing the Fan button. Fan Only mode does not require the use of the exhaust hose.
TIMER (DELAYED SWITCH ON / OFF) FUNCTION
This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time hours delay can be set, enabled and disabled. The timer is adjustable between 1 – 24 hours.
SETTING SWITCH OFF TIMER
With the air conditioner operating in any function mode, press the Timer button. The display timer setting will come on. Set the desired time delay OFF hours by pressing the and buttons. The time increments are at 1 hour to up to 24 hours. When the delay time set has elapsed, the air conditioner switches off. To cancel the delayed switch off function, press the Timer button or turn off the air conditioner.
SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off, press the Timer button. The display timer setting will come on. Set the desired time delay ON hours by pressing the and buttons. The time increments are at 1 hour to up to 24 hours. When the delay time set has elapsed, the air conditioner switches on. To cancel the delayed switch on function, press the Timer button or turn on the air conditioner.
AUTO RESTART
In the event of a power outage, the air conditioner restarts at the previously set function mode and settings when power is restored.
NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are.
- The compressor may make a pulsating or high pitched sound.
- Water running from the evaporator to the water tank may make a splashing sound.
- Refrigerant flowing may make a gurgling sound.
- Fan sound may come from front and back air vents.
COMPRESSOR LOCK OUT
This portable air conditioner is optimized to operate in an ambient temperature of 64°F – 90°F. The compressor cir-cuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents over heating of the compressor and possible circuit breaker tripping.
WATER DRAINAGE
During the process of cooling, some water will be extracted from the air into the unit. Most of this water is used to cool and exhausted to the outside. If the unit is operated in high humidity or low temperature environment, water will be collected in the reservoir inside the unit. If the reservoir is full, the compressor will stop. To continue the cooling function, please drain the water.
REMOTE CONTROL
The portable air conditioner can be switched on by the remote control. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. Reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet.
NOTE
Other appliances in the same room controlled by a remote control TV, radio,
stereo, etc.), may cause interferences. Electronic and fluorescent lamps may
interfere with the signal transmissions between the remote control and the air
conditioner.Remove the batteries if the remote control is not used for long
periods.
INSTALLING BATTERIES
To insert the batteries, open the flap on the back of the remote control by sliding if off. Strictly adhere to the polarity signs on the bottom of the battery housing, close the flap once the batteries have been inserted.
- Only use two dry LR03 AAA 1.5V Batteries (included) in the remote control.
- Always change both batteries at the same time.
Notes
- Do not drop the remote control.
- Do not place the remote control in a location exposed to direct sunlight
- The remote control should be placed about 1 meter or more away from the TV or any electrical appliances.
CARE AND MAINTENANCE
IMPORTANT
Switch off the air conditioner and disconnect the plug from the power
outletDrain water by removing the drain plugAlways transport the air
conditioner in an upright position only
CLEANING THE AIR FILTERS
To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the pre-filter at least once every two weeks.This unit has two air filters a washable pre-filter and an activated carbon filter.
- Switch off the air conditioner and remove the washable pre-filter and an activated carbon filter.
- Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the prefilter.
- Rinse the pre-filter thoroughly under warm running water (no hotter than 100F.
- Dry thoroughly before re-inserting the filters.
NOTE
The activated carbon filter is not washable. It is an optional filter and
should be replaced every 2-3 monthsor as needed if used. Please contact
support@whynter.com for retail sales information
or visit whynter.com for alist of optional accessories.
WARNING
Never operate the air conditioner without the pre-filter in place. Always
switch off the air conditioner and disconnect the plug from the power supply
outlet before cleaning the airconditioner. Use a soft damp cloth to wipe the
body of the unit. Never use harsh chemicals, oil-based products, detergents,
chemically treated cloths or other cleaning solutions.These could possibly
damage the body of the air conditioner.
END OF SEASON STORAGE
This portable air conditioner comes with one end of season storage cover. We highly recommend that storage cover bag is utilized when the unit is not going to be used for a period of time.
WARNING
To avoid danger of suffocation, keep this bag away from babies and children.
Switch off the air conditioner and disconnect the power plug from the power supply outlet before cleaning the airconditioner.•Clean the pre-filter.•Drain the condensed water completely.
- On a warm day, set the unit to Fan only mode for half a day to dry the unit internally.
- Gather the power cord and bundle it.
- Remove the batteries from the remote.
- If leaving the window kit in place, disconnect the exhaust hose from the window slider kit and place the includedcover on the fixture.
- Otherwise, remove the window kit from the window opening.
- To remove the hose connectorfrom the fixture on the window kit, slightly turn, push and gently pull the connector to release.
- Place the storage cover over the air conditioner.
Note
Depending on use, it is recommended that the air conditioner be cleaned
internally annually. Please contact Whynter at
support@whynter.com for internal maintenance
cleaning instructions.
Tips
Keep the exhaust hose as short and straight as possible
The exhaust hose removes heat from the room. It should remain as short and
straight as possible without sharp bends or twists to maximize efficiency. If
the exhaust hose must be extended, do not exceed 9. Turn the air conditioner
on early. Turning the air conditioner on early instead of waiting until the
hottest point of the day will allow the unit to be
more effective. The air conditioner will not have to work as hard to cool the
room down and maintain the set temperature.
Reduce heat sources
Direct sunlight, televisions, computers and other heat generating appliances work against the air conditioner by introducing heat into the space.
- Close window curtains and blinds to keep direct sunlight out.
- Close doors and windows.
- Keep ovens and stoves off.
- Turn off unused lights.
- Add weather stripping around windows and doors.
Keep the air filter clean
Regular cleaning will help keep your air conditioner working properly. Dusty filters and vents greatly reduce the airflow and efficiency of the unit.
- Clean the washable pre-filter regularly.
- Replace the activated carbon filter every 2-3 weeks depending on use.
- Vacuum any accumulated dust from around all vents.
TROUBLESHOOTING
Many common portable air conditioner problems are easily resolved. Try the troubleshooting suggestions below to see if the problems can be resolved before having to contact the service department.
Problem
|
Possible Causes
|
Solutions
---|---|---
The portable air conditioner does not turn on| Power failure / outage.
The automatic switch, line fuse, or breaker has been tripped
The power supply voltage is too low
The power cord is damaged
The L.C.D.I. power plug for the unit is tripped
The internal water reservoir is full
| Restore the power supply
Flip the switch / change the fuse / turn the breaker back on. Also note that you may have too many appliances drawing power on one circuit, you may need to move the other appliances to another circuit
Move the unit onto another circuit with the correct voltage
Call for service. Only authorized per- sonnel should replace damaged power cord or power plug
Press the Reset button on the L.C.D.I power plug.
Drain water from the air conditioner.
Possible loose internal connection.
Please contact Whynter for service.
The unit turns on but the com- pressor does not turn on the fan runs but the unit is not cooling| The room temperature is outside of the operational tolerances of the unit
The Cooling mode is not on
The compressor has not turned on yet because of its time delay
The set temperature is too high
The internal water reservoir is full and Warning Light appears on display
| This unit is designed to work in ambi- ent temperatures of 64°F to 90°F
Press Mode Control until the Cooling indicator light is shown on the display.
Give the compressor 3 minutes to turn on after the Cooling mode has been selected.
Set the air conditioner to a lower temperature. It is recommended to set the temperature to at least 5°F of the am- bient temperature.
Either manually drain the water by removing the drain plug or allow the unit to exhaust the water itself by run- ning the fan only mode. Then cooling will resume Possible loose internal connection. Please contact Whynter for service
The air coming out of the unit is not very cold, or the airflow volume is weak| The filters are dirty or obstructed
The air intake or exhaust is ob- structed
The unit is set in DEHUMIDIFY or FAN mode
The unit is set to low fan speed
| Clean the air filters
Make sure there is at least 20″ of clearance from the air intake. Make the length of the exhaust hose is as short as possible
Set the unit to Cooling mode
Set the unit to a higher fan speed
Problem | Possible Causes | Solutions |
---|---|---|
The unit has worked for a long time, but the room is not cold enough | Windows |
or doors are pen
There are too many people in the room
There is direct sunshine into the room
The room is a kitchen or with many heat producing appliances
There is a server in the room
The room is too large
| Close all windows and doors
You may need additional cooling or another air conditioner
Close curtains or blinds and try to min- imize the amount of direct sunlight into the room
You may need additional cooling or
another air conditioner
The unit is very noisy| The unit is not level
The surface underneath the unit is uneven
Low power voltage
| Make sure the unit is on hard, level and stable surface
Move the unit to a location with a level and hard floor
Make sure the wall outlet and support the required power consumption of the air conditioner and do not use an extension cord
The unit leaks water| The unit is tilted or not leveled
The water tank is full
| Make use the unit is leveled
Drain water from the drain plug at the back of the air conditioner
Fan speed cannot be changed| Fan speed differences are not very noticeable| 9The fan speed difference is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the differ- ence between high and low fan speed settings.
ONE YEAR LIMITED WARRANTY &THREE YEAR WARRANTY ON COMPRESSOR
This WHYNTER product is warranted to the original owner, purchased from an
authorized Whynter dealer within the 48 U.S. continental states, for one year
from the original purchase date against defects in material and workmanship
under normal residential usage. Should your WHYNTER product prove defective
within one year from the date of purchase contact Whynter’s Customer Support
team with the serial number and proof of purchase to make a warranty claim. A
Return Authorization number must be issued before returning any parts or
products. Parts or products received without a Whynter issued Return
Authorization number will be refused. Under this warranty, Whynter will repair
or replace any parts found defective with new or remanufactured parts or
exchange the defective product with a new, refurbished, or remanufactured
product at our discretion. All defective products and parts covered by this
warranty will be repaired or replaced on a mail-in basis to Whynter’s Service
Center. This warranty is not transferable. After the expiration of the
warranty, the cost of labor and parts will be the responsibility of the
original owner. The compressor of portable air conditioners is warranted for
an additional two years after the one year limited warranty expires from the
date of purchase. Return freight is prepaid by Whynter within two months of
purchase. After two months to one year, the customer will be responsible for
the return freight cost to Whynter’s Service Center. Please package the
product carefully in its original packaging to avoid damage in transit.
Whynter is not responsible for damage resulting from shipper mishandling or
improper packaging. Please retain the original box and packaging materials.
THIS WARRANTY DOES NOT COVER
- Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.
- Improper power supply such as power surge, low voltage, defective household wiring or inadequate fuses.
- Use in commercial or industrial applications.
- Damage, accidental or otherwise, to the product while in the possession of a consumer not caused by a defect in material or workmanship.
- Damage caused by consumer misuse, tampering, lack of maintenance or failure to follow the care and special handling provisions in the instructions.
- Damage to the finish of the case, or other appearance parts caused by wear.
- Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.
- Removal, Replacement Packaging, Freight and Insurance cost for the warranty service.
- Products sold AS IS or from an unauthorized reseller.
- Products that have had their serial numbers removed or defaced.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES CUSTOMER’S SOLE AND
EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR
REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED
TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR.
WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS
PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS
WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO
NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE- QUENTIAL
DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE
LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES
YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE
TO STATE.
The warranty, product contents and specifications are subject to change at any
time without notice please refer to www.whynter.com
for the most current information. Please retain the original proof of
purchase. To register your warranty, please visit
www.whynter.com and fill out the online Warranty
Registration form. Please be sure to include a copy of your purchase invoice.
To obtain service or information, contact Whynter LLC via email at
support@whynter.com or call 866-WHYNTER
(866-949-6837). Copyright 2017 Whynter
LLC www.whynter.com
References
Read User Manual Online (PDF format)