BOX SPECIFICATIONS

  • Internal Volume  ………………………………………………………….. 12L
  • Load Configuration ………………………………… Parallel In
  • Box Type …………………………………………………… Sealed Box
  • Box Material …………………………………………………………. 0.59″ MDF
  • Finish Material …………………………Non-Woven fabric
  • 3Db Dropping Point ………………………………………………….48Hz

MEASUREMENTS

  • Height……………………………………………………………………..13.6″
  • Width …………………………………………………………………………..16.7″
  • Depth 1 …………………………………………………………………4.82″
  • Depth 2 ………………………………………………………………….7.9″

SPECIFICATIONS

  • Speaker Type  ……………………………………..10″
  • Total Impedance ……………………………………………………………. 2 ohm
  • RMS Power Handling …………………………………………….350W
  • MAX Power Handling …………………………………………..700W
  • Sensitivity (1w/1m) ………………………………………………………….83dB
  • Frequency Response ………………………………………..38-250Hz

MOTOR

  • Voice Coil Diameter …………………………..1.5″ / 38.6mm
  • Voice Coil Former Material ……….. Aluminum
  • Winding Material ……………………………………………………….EISV
  • Cone Material ……………………………………………………………….. IPP
  • Surround Material …………………………………… Rubber
  • Basket Material ………………………………………………….. SPCC
  • Magnet Material ……………………………………………………. Ferrite
  • Magnet Weight …………………………………………………………… 40 oz

AMPLIFIER

  • Amplifier Class ……………………………………………………… Digital
  • Amplifier Type ………………………………………Monoblock Subwoofer
  • Number of Channels ………………………………………………………1CH
  • Minimum Impedance …………………………………………………… 2 ohm
  • Signal to Noise Ratio ………………………………………………….75 dB
  • Efficiency @ 4ohm……………………………………………………..75%
  • Total Harmonic Distortion (T.H.D) …………………..0.3%
  • Low-Level Input Range……………………………….0.1-0.6 V
  • High-Level Input Range ……………………………..Yes
  • Selectable X-Over ……………………………….LPF Fixed
  • X-Over Filter Range…………………………………….. 50 – 200 Hz
  • Bass Boost Range ……………………………………….0-6 dB
  • Bass Boost Frequency ……………………………50 Hz
  • Phase Selector ………………………………………………………………0-180°
  • Led Indicator …………………..Power – Protection
  • Power Input Terminal Size ………………… 8ga
  • Fuse Size ……………………………………………………….. 30 A
  • Remote Level Control ……………………………………………..Yes
  • Thermal Protection …………………………………….. Yes (75°C / 167°F)
  • Over-Load Protection …………………………………………Yes
  • DC Output Protection………………………………………Yes
  • Short Circuit Output Protection …………………Yes
  • Voltage Input Protection …………..Yes