POOLHACKER YC033 Wireless Floting Pool Thermometer Instruction Manual

June 1, 2024
POOLHACKER

POOLHACKER YC033 Wireless Floting Pool Thermometer

POOLHACKER-YC033-Wireless-Floting-Pool-Thermometer

What’s Inside the Box

  • Temperature and Humidity Monitor (Receiver)
  • Pool Thermometer (Transmitter)
  • AA Battery * 2
  • User Manual *1

Component Names

Temperature and Humidity Monitor (Receiver)

  1. Current Detected Temperature
  2. Pool Thermometer Battery Level
  3. Current Channel Number
  4. Current Indoor Temperature
  5. Battery Level of Poolhacker Monitor
  6. Current Indoor Humidity
  7. 24H/All-Time maximum/minimum values 24
  8. 24H/All-Time maximum/minimum values 24
  9. 24H/All-Time maximum/minimum values 24
  10. 24H/All-Time maximum/minimum values 24
  11. MAX/MIN Button
  12. ℉/℃ Button
  13. CH/R Button

Pool Thermometer (Transmitter)

POOLHACKER-YC033-Wireless-Floting-Pool-Thermometer-
fig-6

  1. Battery Level
  2. Current Detected Temperature
  3. Transmit Flag
  4. ℉/℃ Button/ Transmit Buttons
  5. Charging Port
  6. Pool Temperature Probe
  7. Fixed Lanyard Hole

Technical Parameters

  • Transmission Distance: up to 400 ft( 120m) in open space, if there is interference, the transmission distance will be limited.
  • Temperature and Humidity Monitor (Receiver)
  • Battery: 2*AA 1.5V (Included)
  • Temperature measurement range: -20~70℃ (-4℉~158℉)
  • Temperature measurement accuracy: ±0.3℃ (±1℉)
  • Temperature display accuracy: 0.1℃ (0.1℉)
  • Humidity measurement range: 0~ 99%
  • Humidity measurement accuracy: ±5%
  • Humidity display accuracy: 1%
  • Maximum number of thermometer channels supported at the same time: 9

Pool Thermometer (Transmitter)

  • Temperature measurement range: -40℃~70℃ (-40℉~158℉)
  • Temperature measurement accuracy: ±0.2℃(±0.3℉)
  • Temperature display accuracy: 0.1℃(0.1℉)
  • Sampling period: 10s
  • Waterproof grade: IPX7
  • Battery: Lithium battery 3.7V/2500mA
  • Endurance: >6 months
  • Charging time: <5H

Battery and Charging

Temperature and Humidity Monitor (Receiver)

  1. Push down the back cover of the receiver.
  2. Insert the batteries into the battery compartment as shown in the illustration.

Pool Thermometer (Transmitter)

  1. To charge, connect the provided cable to the Type-C charging port of the Transmitter and the USB power adapter.
  2. Use a standard 5V 2A power adapter to avoid battery damage.
  3. The battery level on the screen will flash during the charging process, and the battery indicator will show full capacity after the charging is completed.
  4. The device can work continuously for more than 6 months under full charge.

Warning: Before charging, please wipe off any water residue on the transmitter, and when charging is complete, please tuck the battery cover completely into the charging hole to prevent the device from being damaged by water.

Button Operation

Temperature and Humidity Monitor (Receiver)

  1. Press it to view the maximum/minimum values. If there is no operation for 30 seconds, the screen will automatically display the current detected value again.
  2. Press and hold it for more than 3 seconds to clear the current channel maximum/minimum values and start recording again.

℃/℉ Button:
Press it to switch the temperature unit between ℃ and ℉.

CH/R Button:

  1. Bound channels on the receiver are displayed alternately for 10 seconds.
  2. Press it to switch between the bound channels (CH1, CH2, CH3…), You can bind up to 9 devices.
  3. Press and hold it for 3 seconds to reset the registration of the current channel pool thermometers (transmitters). We should place the pool thermometer close to the indoor monitor and long press the pool thermometer button to transmit data for once so that they can reconnect again and complete the registration.

Pool Thermometer (Transmitter)

  1. Press it to switch the temperature unit between ℃ and ℉ on the pool thermometer.

  2. Press and hold it for more than 1 seconds to transmit the detected temperature from the pool thermometer to the temperature and humidity monitor and the transmit flag will blink several times
    Tips : We should place the pool thermometer close to the indoor monitor and let the pool thermometer transmit data for once so that they can reconnect again and complete the registration.

  3. Power on/off: Long-press the button for 3 second.

  4. After the first transmission, the temperature is detected in real time, and the data is transmitted once every about 15s

Add Sub-Devices:

  1. Firstly, make sure the batteries of the temperature and humidity monitor (receiver) are installed correctly and working properly.
  2. Secondly, fully charge the battery of pool thermometer (transmitter), and place the thermometer as close to the temperature and humidity monitor (receiver) as possible.
  3. Press it to switch between the bound channels (CH1, CH2, CH3…), long press it to switch to the channel you want to bind, long press it and the screen will show (—-), at this time, long press the button on the transmitter, and the monitor (receiver) completes adding a sub-device and displays the channel number of the pool thermometer (transmitter).
    Note : If you fail to add sub-devices, please repeat steps c to add the device.

Warning :

  1. Our equipment has been paired at the factory, you can use it directly when you receive the goods and test it well.
  2. Before charging, please wipe off any water residue on the transmitter, and when charging is complete, please tuck the battery cover completely into the charging hole to prevent the device from being damaged by water.
  3. Do not use the pool thermometer (transmitter) submerged below a horizontal surface, as the signal will not be transmitted below the surface of the water.
  4. Please place the temperature and humidity monitor (receiver) closer to the pool thermometer (transmitter) by a window for best transmission. if there is interference, the transmission distance will be limited.

FCC Warning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • Caution : Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

How to Obtain After-Sales Service

If you have any further questions during usage or require replacement parts, please contact our after-sales service at info@poolhacker.com , and we will promptly assist you.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals