MOBILE PATIENTLIFT MP-P01 Bridge Bath Lift User Manual Specifications:
- June 1, 2024
- MOBILE PATIENTLIFT
Table of Contents
- MP-P01 Bridge Bath Lift
- Specifications:
- Product Usage Instructions:
- 1. Operation before Use:
- 2. Prohibition:
- 3. Matters Needing Attention:
- Charging Guidelines:
- Q: Can the Bridge Bath Lift be used in non-standard
- Q: How should I position myself when using the bath lift?
- Q: Is the bath lift waterproof?
MP-P01 Bridge Bath Lift
“`html
Specifications:
-
Designed to assist users with limited mobility in bathing
-
Compact and foldable design for easy storage and
transportation -
Fits easily in standard bathtubs with 6 suction cups for
stability -
Battery-powered with waterproof components
-
Modular design with foldable back and seat
-
Intelligent protection control for safe operation
Product Usage Instructions:
1. Operation before Use:
Before the first use, carefully read the instructions to
familiarize yourself with the bath lift for easier operation.
2. Prohibition:
Avoid modifying the device and ensure safety by not interfering
with moving parts.
3. Matters Needing Attention:
-
Clean hand control and charger with plugs disconnected; charger
only with a dry cloth. -
Contact professional dealer if signs of damage on hand control
or charger are noticed. -
Sit in the middle of the seat, lean back, and operate the hand
control with care. -
Avoid lifting the bath lift while using other electrical
appliances to prevent interference.
Charging Guidelines:
Lithium-ion batteries must be charged for at least 12 hours
before first use. Store battery power at 40-60% when not in
use.
FAQ:
Q: Can the Bridge Bath Lift be used in non-standard
bathtubs?
A: The lift is designed to fit standard bathtubs; non-standard
or customized tubs may not be suitable.
Q: How should I position myself when using the bath lift?
A: Sit in the middle of the seat, lean back, and operate the
hand control with care for safe usage.
Q: Is the bath lift waterproof?
A: The bath lifter, except the charger, is water-proof for safe
usage during bathing.
“`
Bridge Bath Lift User Manual
Climbing Steps, Inc 1661 M Dixie Hwy Bay 12, Pompano Beach, FL 33060
212-366-5483 |
www.MobilePatientLift.com
1 . Product description
The Bridge Bath Lift is designed to assist users with limited mobility to
enter and leave the bathing space more easily and conveniently at home, making
the bathing easier and more enjoyable.
Bridge Bath Lift is compact in structure an foldable, which takes up little
space, and can be easily stored and transported.
Bridge Bath Lift fully considers the specifications of the common bathtub, so
that it can be easily positioned in any standard bathtub (some non-standard or
specially customized bathtubs may not be suitable}.
Bridge Bath Lift is equipped with 6 suction cups at the bottom, which makes
its positioning more stable and has a good anti-slip effect.
Bridge Bath Lift is completely powered by batteries, and does not need to
external electrical transmission lines, so it is convenient and reliable to
use; the bath lifter, except the charger, is of water-proof. You can also lift
and lower the bath chair during bathing.
Bridge Bath Lift uses modular design, the back and the seat can be folded and
disassembled, and automatically locked on the seat base when the bath lifter
is raised, which can prevent the back of the chair from tilting accidentally;
intelligent protection control can ensure that the hand control can lower the
bath lifer when the power is insufficient.
In this user manual, you will get all the information about the Bridge Bath
Lift including usage, storage, etc.
2
& 2. Items before use
2.1 Operation before use
(1) Before your first use, please read the instructions carefully, which will
make you more familiar with the bath lift, and its operation will also become
simpler and more controllable;
(2) Please keep this instruction for anyone who may touch or use the bath lift
(3) First, evaluate the user to ensure that it is suitable. The evaluation
items include but are not less than the user’s we ight, volume,
cognitiveability, joint mobility, etc. Please do not give the bath lift to
unsuitable people. When a disabled person uses the device, there must be an
escort or an alarm device nearby; (4) Use it in a standard bathtub that meets
the regulations, and ask an assistant or professional to determine whether the
use environment meets the requirements; (5) Before each use, please check
whether the suction cup and seat surface are clean, remove stains and
adsorbents, check and conduct a trial operation that all parts of the
equipment are complete and whether they are damaged, and at the same time,
verify whether the emergency stop button works; (6) If you use bath oil, bath
salts and other toile trie s, you need to confirm to prevent high
concentrations of toiletries from damaging the structure and sliding function
of the bath lift; (7) When using, the user should sit down slowly and calmly
to avoid excessive stimulation and damage to the bath lift or personnel; (8)
Please use the matching hand control to operate; (9) Please install the bath
lift according to the installation instructions.
& 2.2 Prohibition
(1) Do not overload; (2) Do not stand or kneel on the bath lift; (3) During
use, do not sit on the opposite side; (4) Do not use on heavily sloped (over
5°) or surfaces with step; (5) Do not use if parts are missing; (6) Do not use
for other purposes except bathing; (7) Do not le ave children alone for using;
(8) During maintenance and use, do not put hands, feet and other body organs
and objects into moving parts; (9) Do not place sundrie s (such as toothbrushe
s, razors, etc.) near cross structure. (10) Do not place the hand control near
heat sources; (11) During lifting and lowering of the bath lift, do not put
body parts such as hands, feet, and other items into
the moving parts; (12) Do not modify this device.
3. Matters needing attention
(1) Please use the matching charger to charge; (2) The optimal capacity of the
battery may be reached after a few charging cycle; (3) When charging, keep
away from water, heat, etc.; (4) The hand control comes standard with three-
color indicator lights. In normal use, the green light indicates that the
power is sufficient, the blue light indicates that the power is insufficient,
and reminds to charge. When the red light is on, it indicates that the power
is seriously insufficient and needs to be charged immediately to prevent
Sudden power failure during the proces; (5) Under normal charging conditions,
the indicator light of the charger is red, and when the battery is fully
charged, the indicator light of the charger is green, and the charging time is
about 2.5 hours; (6) The charger is designed for charging the hand control and
cannot be used for other purposes; (7) The battery is built into the hand
control, please do not disassemble the hand control without permission; when
the bath lift is being transported, please confirm that the wires are in
disconnected mode and are not in charging state ; Prevent damage to the bath
lift and personnel caused by falling, collision, etc.
3
(8) In the process of cleaning the hand control or the charger, please make
sure that the plugs are disconnected; the charger can only be cleaned with a
dry cloth;
(9) Although the hand control and charger are reliable designs, they still
cannot withstand the risk of falling; if you find some signs of damage on the
surface of the hand control and charger, please contact your professional
dealer immediately; we will provide corresponding service;
(10) Please sit in the middle of the seat of the bath lift, lean back on the
back of the chair, stretch your legs forward, put one hand on the side panels,
or on your lap, and operate the hand control with another hand;
(11) Our bath lift has passed the EMC test. When you use other electrical
appliances in the bathroom or use a mobile phone, please try not to lift the
bath lift at the same time to prevent electromagnetic interference and make
the equipment abnormal. When the bath lift is abnormal, please contact your
dealer for assistance.
· Please carefully read the following important information about the hand
control (rechargeable lithium ion battery)
It must be charged before the first use
Since lithium-ion batteries must not exceed 30% of their nominal capacity
during transport, they must be charged for at least 12 hours before first use.
It is recommended to keep the battery power at 40-60% when storing
When not in use for a long time, the hand control needs to be disconnected
from other parts and stored in an environment with low temperature, low
humidity, no dust and no corrosive gas to maintain the best performance when
the battery is used subsequently.
The following table shows the recommended storage time under the corresponding
storage environment. After the storage time is exceeded, the battery should be
put into use.
Storage time
Storage environment
1 year
10-25°C (1*), 40 – 70% RH (non-condensing)
3 months
0-35°C (1*), 30 – 75% RH (non-condensing)
1 month
-10-50°C (1*), 20 – 80% RH (non-condensing)
It must be charged and discharged once within 6 months of receipt; during
storage, the hand control (battery) must be charged and discharged once every
6 months.
Rechargeable batteries are one of the consumables that have a limited life
span and continue to degrade in performance. Normal battery wear and tear is
not included in returns and claims.
· Charging process (1) Disconnect the hand control from the bath lift. (2) Ensure that the connection parts and the charger are sufficiently dry. (3) Plugging the female plug of the hand control into the male plug of the charger. (4) Plug the charger into a suitable outlet. Charging voltage range: 100-240VAC. (5) When charging is finished, please disconnect the charge in time to avoid affecting the battery life.
4
4. lnstallation and usage
· Installation and use environment confirmation
Please check the parts for damage and defects before use. Only use it if you
are sure that there are no damaged or missing parts.
As shown below:
Parts included
CD hand control ® charger
@ backrest (including linear actuator and backpad) @ Base (cushion and 6
suction cups) @ Instruction manual (1) When receiving the bath lift and then
opening the package, please first read the instrution manual. (2) Please take
out the back part of the chair and the seat part, and install the back to the
seat. You can see the following figure for details.
Installation picture
CD Align the backrest hook with the base guide bar.
® Press the hooks on each side of the backrest to connect
them to the base.
@ Complete the installation of the backrest and the base.
5
@ Make sure the top clevis of the actuator is connected correctly with the base hook lock.
CORRECT .J
WRONG x
(3) Please check whether the 6 suction cups at the bottom of the seat have
loosened during transportation or movement. If there is looseness, tighten the
suction cups.
(4) Confirm that there are no obstacles or sundries in the bathtub that may
cause tip over or affect the normal lift of the bath lift, including shower
heads, faucets, fittings, etc..
(5) You need to put the bath lift in the bathtub and ask for help if you have
difficulty.
(6) Please ensure that the floor is dry and free of obstructions to prevent
slipping or other accidents during the handling or placement of the bath lift.
(7) In the process of putting the bath lift into the bathtub, please make sure
that there is enough space in the direction of the back. Prevent the bath lift
from hitting the bathtub or other objects in the bathroom. Also confirm that
there are no relevant obstacles (including but not limited to faucets, shower
heads, etc.) within the range of the bath lift.
(8) Make sure that the 6 suction cups are in fully contact with the bottom
surface of the bathtub.
(9) Please make sure that the male plug of the bath lift and the female plug
of the hand control are entirely dry before connecting them to each other.
(10) Placing the hand control wire on the outside of the bath lift to prevent
the hand control line from being pressed or pulled apart, causing damage to
the line or a poor connection.
(11) Make sure that the bath lift can be lifted properly and safely before
each use.
(12) Press the hand control up button to rise, press the down button to fall,
the stop button has an emergency stop effect. When in the process of
descending, the user is aware of the danger, you can press the stop button,
the bath lift will not be able to descend. You need to press the up button
before you press the down button again.
(13) Textured button to assist those with visual impairments
(14) The hand control is in jog control mode, i.e. the button is valid when
pressed and invalid when released.
(15) When the bathing chair is stored at a lower temperature (e.g. in winter),
if it needs to be used again, allow it to warm up naturally to room
temperature before use.;
(16) After each bath, it is recommended to wash the bath chair with water and
let it dry naturally.
Hand control
6
CD Upper triangle button: Up button – controls the rise of the bath chair ®
Lower triangular button: Down button – controls the descent of the bath chair
@ Round button: Emergency stop button – control the bath chair emergency stop,
and no longer descend, if you need to descend need to first press the up
button and then press the down piece to descend
@ Indicator light: shows the working status of the shower chair · Start use
(1) First, please open the back of the bath lift, and plug the hand control
with the connecctor on the back.
(2) Let the bath lift rise until the sides of the side plate lean smoothly
against both sides of the bathtub; (3) With your back to the bathtub, sit on
the outside side plate; (4) Maintain the above position and move the hips to
the middle of the seat of the bath lift; (5) Put both feet into the bathtub;
(6) Once you are in the bathtub comfortably, use the hand control down button
to drop to your desired position. Keep hands and feet safe during the process;
(7) If the down button is kept pressed, the bath lift will stop at the lowest
point; (8) If conditions permit, have the user operate the hand control rather
than the assistant. This will make the user feel more comfortable and will
reduce the danger; · Storage (1) The user leaves the bath and waits for the
water to drain from the bath before lowering the bath chair to its lowest
point and folding up the back of the chair; (2) Before picking up the bath
lift, make the suction cups inflate by lifting the armrests. Balance the
pressure difference between suction cups and atmospheric pressure to lift the
bath lift easily;
It
(3) Wash the bathing chair equipment with water to remove foam, stains, etc.
(keep the hand control linked to the bathing chair’s plug).
(4) Disconnect the hand control from the bathing chair and wipe it clean with
a dry cloth. (5) Storing the bath chair and hand controls.
7
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>