Eddy TR9002 Slimline Concealed Cistern Instruction Manual

June 1, 2024
eddy

Eddy TR9002 Slimline Concealed Cistern

Eddy-TR9002-Slimline-Concealed-Cistern-product

Product Information

Specifications

  • Slimline Concealed Cistern – Side Entry with Air Gap Technology
  • Flush Volume: 6L/3L
  • Nominal Water Level: 198mm
  • Water Pressure Suitability: 0.1 – 10 bar

Product Usage Instructions

Installation Requirements for AUK1 Air Gap

In order to achieve an AUK1 air gap during installation, there must be at least 300mm in height between the spillover level of the WC pan and the overflow tube within the flush valve.

Fitting Instructions

Please read completely before commencing and retain for future reference.

  1. Ensure wall plugs are suitable for solid stone/brick walls.
  2. If fixing to a stud wall, reinforce the wall adequately.
  3. Install by a qualified plumber or installer.

Operational Instructions

  • Press the large button for a long flush.
  • Press the small button for a short flush.

Care & Safety

  • Do not use caustic chemical substances in the cistern.
  • Test for leaks before enclosing the cistern and before tiling for fully tiled installations.
  • Not suitable for wall hung pans without a suitable supporting frame.

Inlet Valve Adjustments and Maintenance

– Adjust fill valve to change water level (25-32mm below overflow tube).

– Clean the diaphragm if flow rate slows down or doesn’t stop.

FAQ

  • Q: Can I use the product with wall hung pans?
    • A: The cistern is not suitable for use with wall hung pans without a suitable supporting frame.
  • Q: What is the water pressure suitability for the cistern fittings?
    • A: The cistern fittings are suitable for water pressure ranging from 0.1 to 10 bar.

Fitting Instructions

Please read it completely before commencing and retain for future reference

This product must be installed by a qualified fitter or plumber in accordance with and meet the requirements of Water Supply (Water Fittings) Regulations 1999, the Water Supply (Water Fittings) (Scotland) Byelaws 2014 and the Water Supply (Water Fittings) Regulations (Northern Ireland) 2009

Parts included

Eddy-TR9002-Slimline-Concealed-Cistern-fig \(1\)

  1. Cistern
  2. EPS Jacket
  3. Seal – SP12168
  4. Flush Bend Nut SP12168
  5. Flush Bend SP12167
  6. Pan Seal (Cone) SP12170
  7. Side Entry Fill Valve SP19744
  8. Fill Valve Diaphragm SP19756
  9. 2 x Attaching Screws SP12163
  10. Attachment Plate SP12163
  11. Cistern Cover SP12164
  12. Pneumatic Push-button SP12169
  13. Air Hoses SP17421
  14. Flush Valve SP12166
  15. Flush Valve Flapper Seal SP12551
  16. Cistern Fixing Screw SP12163

Fitting dimensions

Eddy-TR9002-Slimline-Concealed-Cistern-fig
20

Installation of the cistern

Eddy-TR9002-Slimline-Concealed-Cistern-fig
\(4\)

Eddy-TR9002-Slimline-Concealed-Cistern-fig \(5\)

note

Check valve not included Connect the water supply to the cistern using an approved double check valve to fluid category 3 in addition to an accessible service/isolation valve.

Installation with a front access panelEddy-TR9002-Slimline-Concealed-
Cistern-fig \(8\)

Installation with a top access panelEddy-TR9002-Slimline-Concealed-
Cistern-fig \(8\)

Installation of pneumatic push-buttonEddy-TR9002-Slimline-Concealed-
Cistern-fig \(9\)

Fixing the toilet

Eddy-TR9002-Slimline-Concealed-Cistern-fig
\(16\)

note

Lubricant not supplied, please use a suitable plumber’s grease. Silicone MUST NOT be used as this may prevent a seal being formed.

important

Great care must be taken when fixing the toilet. Careful cutting of the pipe and alignment are very important to ensure no leaks occur

important

Please support the flush pipe when locating the toilet onto the rubber seal. Failure to do so could result in damage to the flush connection

Adjusting the flush volume

Eddy-TR9002-Slimline-Concealed-Cistern-fig
\(17\)

Inlet Valve Adjustments and Maintenance

By adjusting the fill valve the water level can either be increased or decreased accordingly. Note: the water level within the tank must be between 25-32mm below the overflow tube of the flush valve. The cistern is preset with settings to accommodate this.

Eddy-TR9002-Slimline-Concealed-Cistern-fig \(19\)

Achieving an AUK1 air gap during installation

Eddy-TR9002-Slimline-Concealed-Cistern-fig \(2\)

Operational Instructions

Eddy-TR9002-Slimline-Concealed-Cistern-fig
\(3\)

General Care & Safety

Wall plugs supplied are ONLY suitable for solid stone/brick walls. They are not suitable for use in aerated blocks or similar. If fixing to a stud wall, sufficient extra internal reinforcements must be made to the wall. Screws must locate into suitably reinforced studs and noggins. Take care using power tools – The use of a residual current device (RCD) is recommended. Beware of hidden cables or pipes when drilling. This product can be dangerous if installed incorrectly. This product must be installed by a qualified plumber or installer. It is the installer’s responsibility to check that the fixings are suitable for the installation in hand. Cistern fittings are suitable for Water pressure: 0.1 – 10 bar. Do not add caustic chemical substances (e.g. containing chlorine compounds or similar) into the cistern. These can damage the valve components and cause failure. Before starting to enclose the cistern, the system must be first tested for leaks before 2nd fix commences. Temporarily fix the back to wall pan in place and make connections. Turn the water supply on and flush the pan to check for leaks. This is particularly important to do prior to tiling for fully tiled in installations This cistern is not suitable for use with wall hung pans without the use of a suitable supporting frame.

  • Brought to you by the Roper Rhodes Group
  • Brassmill Lane Trading Estate
  • Bath
  • BA1 3JF
  • t: 01225 303900

Troubleshooting

Cascade – Slimline Concealed Cistern

Please retain for future reference

How to Access your cistern

  1. Remove fascia panel

  2. Remove the blue cover on the cistern

  3. Shut off Water Supply

  4. Unscrew the nut from the flexible hose

  5. Pull out the fill valve

  6. Gently twist & remove flush valve (anti-clockwise)

Eddy-TR9002-Slimline-Concealed-Cistern-fig \(13\) Eddy-TR9002-Slimline-Concealed-Cistern-fig \(14\) Eddy-TR9002-Slimline-Concealed-Cistern-fig \(15\)