CK30 2 180-CK30.2 v2.02 Safety Clearances User Manual
- May 15, 2024
- CK30 2
Table of Contents
CK30 2 180-CK30.2 v2.02 Safety Clearances
Product Information
Specifications
- Model: CK30.2
- Flue Pipe Diameter: 6 inches
- Flue Pipe Material: 24 MSG steel construction
Product Usage Instructions
Safety Clearances
This appliance must be installed in compliance with all local codes and regulations.
Ensure the following safety clearances:
- Minimum clearance for residential installation:
- A to B: 9.5 inches (241 mm)
- B to C: 6 inches (153 mm)
- C to D: 24.125 inches (603 mm)
- D to Roof or Wall exit: 16.375 inches (416 mm)
- Minimum clearance for mobile home or transportable building installation:
- E to F: 4 inches (102 mm)
- F to G: 17.625 inches (448 mm)
- G to J: 37 inches (940 mm)
Floor Protection
- For floor protection, use a minimum of 35 x 42.125 inches (889 mm x 1070 mm) in the USA and 45.25 x 52.125 inches (1150 mm x 1324 mm) in Canada.
- Avoid adhesive-based vinyl flooring in front of the appliance to prevent thermal expansion and warping.
FAQ
Q: What type of flue pipe should be used with the appliance?
- A: The flue pipe must be 6 inches in diameter and constructed of 24 MSG steel. Do not use aluminum or galvanized steel.
Q: What are the recommended clearances for single-wall pipes in Canada?
- A: In Canada, a minimum 18-inch (450 mm) clearance from a single wall pipe is required.
Q: Are any additional kits required for installation in a mobile home or transportable building?
- A: For installation in a mobile home or transportable building, a Fan Kit or Rear Shield Kit along with an Outside Air Kit is required.
MINIMUM CLEARANCES
- This appliance must be installed in compliance with all local codes and regulations. Minimum clearances may only be reduced by means approved by the regulatory authority.
- The flue pipe must be 6” in diameter and 24 MSG steel construction. Do not use aluminum or galvanized steel. Refer to local codes and pipe manufacturer specs for required minimum clearances.
- In Canada, a minimum 18” (450 mm) clearance from a single wall pipe is required.
RESIDENTIAL INSTALLATION| A| B| * C*| D| E**|
* F| J
---|---|---|---|---|---|---|---
Roof or Wall exit; Parallel or Corner min clearances| 9.5”
241 mm
| 6”
153 mm
| 24.125”
603 mm
| 16.375”
416 mm
| 4”
102 mm
| 17.625”
448 mm
| 37”
940 mm
MOBILE HOME (USA) OR TRANSPORTABLE BUILDING (CAN) INSTALLATION
Roof exit only; Parallel or Corner min clearances
*Fan Kit or Rear Shield Kit + Outside Air Kit required
| 9.5”
241 mm
| 6”
153 mm
| 24.125”
603 mm
| 16.375”
416 mm
| 4”
102 mm
| 17.625”
448 mm
| 37”
940 mm
Dimension
G = 3” (77 mm) in USA
8” (203 mm) in Canada
| H = 16” (406 mm) in USA
18” (456 mm) in Canada
| I = 0” (0 mm) in USA
8” (203 mm) in Canada
| * K = 18” (456 mm) for single wall pipe in Canada
---|---|---|---
FLOOR PROTECTION
This appliance does not require thermal hearth pad floor protection; however, if installed on a combustible floor, a non-combustible floor shield must be used. In the USA, this floor shield must extend 16” out from the front and 8” out from either side of the fuel-loading door. In Canada, to comply with CSA B365, any combustible covering beneath the appliance and/or within the area extending horizontally at least 18” (450 mm) beyond the appliance on any side equipped with a door, and at least 8” (200 mm) beyond the appliance on other sides, shall be protected by a continuous, durable, non-combustible pad that will provide ember protection. The 18” (450 mm) ember protection required on any side with a door shall extend for the full width of the appliance plus the 8” (200 mm) required on each side of the appliance without a door. Where an appliance is installed less than 8” (200 mm) from a wall, the ember pad need only extend to the base of the wall. An ember pad shall not be placed on top of a carpet unless the pad is structurally supported to prevent displacement and distortion. A non-combustible shield is also required underneath the chimney connector and extends at least 2” on either side of the chimney connector. This shield does not need an insulation value but must be listed under UL 1618-2009 (Type 1) and have a minimum size of 35” x 42.125” (889 mm x 1070 mm) in the USA and 45.25” x 52.125” (1150 mm x 1324 mm) in Canada Blaze King does not recommend adhesive based vinyl flooring in front of appliances due to thermal expansion and warping which could be permanent.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>