TOMMY Teleshopping YS-ET05 Thermometer User Manual
- June 6, 2024
- TOMMY Teleshopping
Table of Contents
Model YS.ET05 Made in Chaina
Quick use guide
Safety Notification
- Start measuring after the thermometer adapts to the environment for 30 minutes.
- A small amount of medical alcohol should be dipped into a cotton swab frequently to clean the sensor head, so as to avoid dust covering the sensor head lens and making the measurement result incorrect.
- During the measurement process, take out the machine after hearing the “beep” sound to avoid low measurement results.
Correct temperature measurement procedure
-
Power on
Shot press the [SCAN] key and the screen will be fully displayed for 1 second. The last measurement record value will be displayed for 1 second, and then enter the temperature measurement mode.
-
Surface mode
In the measurement mode, short press the [ SET ] key, when the screen displays [ Surface ], press the [SCAN] key on the object to start measuring the temperature, will get the temperature data after about 1 second.
-
Environmental mode
In the measurement mode, short press the [ SET ] key, when there is no words displayed on screen, will enter Environmental mode, and then press the [SCAN] key the start measuring the temperature, get the temperature data after about 1 second.
-
Power off:
If it is not used for about 15s, it will automatically shut down.
Infrared Thermometer Manual
Note:
- The operating ambient temperature range of this product is 10° C ∼ 40° C.
- Do not expose the product to extreme temperatures (below -20° C or above 50° C), excessive humidity (greater than85% RH) environment.
- Do not scratch the lens of the thermometer, so as not to affect the accuracy of the temperature measurement
- This product can only use the battery cover provided by our company. If other parts or materials are used, they may not be able to turn off or will not save.
- If the battery cover is damaged or missing, please contact the manufacturer to replace or purchase.
- If accessories other than those provided by the manufacturer are used, measurement results may be incorrect.
- The thermometer may not be able to accurately measure body temperature at the end of its useful life. Discarded thermometers or parts thereof may cause environmental pollution. When disposing of used thermometers or their components, please dispose of them in accordance with relevant local environmental protection regulations.
- The use and storage of this product have requirements on the temperature and humidity of the environment. Please operate as required. If the measurement is performed beyond the specified temperature and humidity, the measurement results may be biased, and its accuracy cannot be guaranteed.
- Operating environment: Temperature: 10°C ∼ 40°C Relative humidity: 585%HR
- Transportation and storage environment: Temperature: -20°C ∼ 50°C
Relative humidity: 15%HR ∼ 93%HR (Product pictures are for reference only, please prevail in kind!)
Note: This manual can be used as a technical / user manual. (Reference value of normal human body temperature]
(Product structure and composition) It is mainly composed of the
temperature measuring head, display screen, and body.
(Contraindications) Measurement of local lesions such as inflammation,
trauma, and postoperative conditions.
Display information
Measurement location indication: During measurement, the icon flashes to
indicate the correct measurement location.
Temperature measurement value indication: When the measurement is
completed, the temperature reading is displayed. Temperature unit indication:
display the temperature unit of measurement in ° C or ° F.
Low battery symbol Indicates: when the battery is low, the icon prompts
to replace the battery.
Memory symbol Indication: Currently in-memory query mode.
[Loading and replacing batteries]
When the low voltage symbol “ “appears, replace the battery immediately. The
steps are as follows
- Hold the battery cover of the product and push It diagonally upward to open the battery cover.
- Install 2 x AAA batteries as shown on the positive and negative terminals of the machine. Close the battery cover.
[Note] Remove the battery if the thermometer will not be used for a long time. For the method of discarding used batteries, please refer to relevant laws and regulations.
(Measurement precautions)
- It is recommended to try it yourself first, so as to become familiar with how to operate this product.
- In order to avoid affecting the accuracy of the thermometer due to external over-cooling or over-heating environment, the thermometer must be placed in a general environment at room temperature of about 16 ° C -35 ° C for at least 30 minutes before use to avoid incorrect measurement.
- The subject should be at least 20 minutes at room temperature before measurement to allow the body temperature to balance.
- After strenuous exercise, you should rest for at least 30 minutes before measuring
- When repeating the measurement continuously, please remove the probe head between each measurement and rest for at least 5 seconds before taking the next measurement, so as to obtain the most accurate measurement result.
- After each measurement, the detector head needs to be cleaned and cleaned with alcohol to avoid contamination from affecting the measurement results to ensure the accuracy of the next measurement.
[Measurement steps]
There is no display in the off state. Short press the [SCAN] key, the screen
will be displayed for 1 second, and the last measurement record value will be
displayed for 1 second, and then enter the temperature measurement mode
[Correct measurement posture]
Align object to measure within 0-20mm
[Memory query mode]
When there are no backlight and no words display on the [ SET ] , press the
function button to enter the memory query mode, short press the [ SET ] key
again, you can query all the memory data cyclically, there are 32 groups . As
shown below:
Surface mode
In the measurement mode, short press the [ SET ] key, enter the object
temperature measurement mode when the screen displays [ Surface ], and then
press the [SCAN] key at the center of the object to start measuring the
temperature. The temperature will be measured after about 1 second. After
about 3 seconds, the buzzer beeps briefly, and then presses the [SCAN] key to
measure the temperature again. As shown below:
[Unit conversion]
In the bright screen with word measurement mode, press the [ SET ] button to
switch the temperature unit to be degree centigrade/Fahrenheit degree
(Technical Specification)
Product name: thermometer
Model / Specification: VS-EMS
Measurement range: 32.0°C-42.2°C
Maximum allowable error: 35°C∼42.0 ° C ± 0.2 ° C Others: ± 0.3 °C
Resolution: 0.1°C
Memory function: 32 groups
Operating environment: temperature is 10 ° C ∼ 40 ° C; Relative humidity
is ≤ 85%HR: Air pressure: (70∼ 106) kPa
Transportation and storage environment: temperature is -20°C∼40°C;
Relative humidity is 15%HR∼93%HR
Air pressure: (70 ∼106) kPa
Power: 2 × AAA battery (DC 3V) (Not Included)
Appearance size: 150 x 95 x 44 mm
Body weight: about 110g (without battery)
Automatic shutdown: 30 sec ∼40 sec
Software release version: A.01
Accessories: one infrared thermometer, one product manual, one
certificate
[Abnormal conditions and possible causes]
Display message Possible cause
No response after pressing
the measurement button| The battery is dead, please replace the battery;
or the battery is not inserted correctly
---|---
| Low voltage display, please replace the battery in time
| The EEPROM is abnormal. Please send it to the nearest service center for
repair.
| The sensor is not welded, please send it to the nearest service provider for
repair.
| The measurement is over 42.2 ° C (108 ° F)
| Measurement results below 32 ° C (89.6 ° F)
| Ambient temperature is too high
| Ambient temperature is too low
Maintenance
Keep the surface of the thermometer clean and tidy, helps the life cycles.
Clean the product with soft cloth
The thermometer if forbidden to be placed into liquid directly.
Caution
Note:
■ Do not use it in improper temperature or humidity.
Do not explore the thermometer near large electromagnetic fields such as found
with cordless or cell phones.
Do not use the chemical such as gas to clean it. Keep the device away from
water and heat, including direct sunlight.
Take off the battery inside if long time no use (over 3 months). Do not use it
if there is some damage at the sensor.
Do not fall the thermometer heavily into the ground or it might get broken.
Do not put it with metal products together such as battery, or coin, in case
of short circuit.
Do not expose to a fire, or it might explode. The battery should follow local
standards.
Electro-Magnetic Compatibility
Note:
- This product conforms to relevant requirements of YY0505 electromagnetic compatibility;
- The user shall install and use the product according to the electromagnetic compatibility information provided in the random file;
- Convenient and mobile RF communication equipment may affect the performance of the product, avoid strong electromagnetic interference when using, such as close to the mobile phone, microwave oven, etc.;
- The guide and manufacturer’s statement are attached.
Warning:
- This product should not be used close to or stacked with other equipment. If it must be used close to or stacked, it should be observed to verify whether the equipment can operate normally under such conditions.
- This product may be disturbed by other equipment even if other equipment meets the launch requirements of corresponding national standards.
EMC Tables:
Guidance and manufacture’s declaration-electromagnetic emissions
The YS-ET05 is intended for use int the electromagnetic environment specified
below. The customer of the user of the YS-ET05 should assure that it is used
in such an environment.
Emissions test| Compliance| Electromagnetic environment
guidance
RF emissions
GB 4824| Group 1| The product uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely to cause any
interfe-rence in nearby electronic equipment.
RF emissions
GB 4824| Class B| The product is suitable for use in all establishments,
including domestic establishments and those directly connected to the public
low-voltage power supply network that supplies building used for domestic
purpose.
Harmonic emissions
GB 17625.1| Not Applicable
Voltage fluctuations/ Flicker emissions GB 17625.2| Not Applicable
Guidance and manufacture’s declaration-electromagnetic immunity
The YS-ET05 is intended for use int he electromagnetic environment specified
below. The customer of the user of the YS-ET05 should assure that it is used
in such an environment.
Immunity Test| IEC 60601 test level| Compliance level|
Electromagnetic environment guidance
Electrostatic discharge
GB/T 17626.2| GB/T 17626.2
±6kv contact
±8ky air| Electrostatic discharge
±6kv contact
±8kv air| Floors should be wood, concrete or caramic tile. If floors are
covered with synthetic material, the relative humidity should be at least 30%.
Electrostatic fast transient/burst
GB/T 17626.4| ±2kv for power supply lines
±1KV for input/output lines| Not Applicable| Not Applicable
Surge
GB/T 17626.5| ±1kv line(s) to line(s)
±21(v line(s) to earth| Not Applicable| Not Applicable
Interruptions and voltage variations on power supply input lines
GB/T 17626.11| <5%Ut,for 0.5 cycle (>95% dip in UT)
40%Ut for 5 cycles (60% dip in UT)
70%Ut for 25 cycles (30% dip in UT)
<5%Ut (>95% dip in UT) for 5 sec|
Not Applicable
| Not Applicable
---|---|---|---
Power frequency
(50/60Hz)
GB/T 17626.8| 3A/m| 3A/m,
50/60Hz| Power frequency magnetic fields should be at levels characteristic of
a typical location in a typical commercial or hospital environment
NOTE UT is the a.c.mains voltage prior to application of the test level
Guidance and manufacturer’s declaration – electromagnetic immunity
The product is intended for use in the electromagnetic environment specified
below. The Customer or the user of the product should assure that it is used
in such an environment
Immunity test| IEC 60601 test Level| Compliance level| Electromagnetic
environment – guidance
Conducted RF
GB/T1 7626.6
Conducted RF
GB/T17626.3| 3V(Value)
150 kHz to 80 MHz
3V/m
80 MHz-25 GHz| Not applicable
3v/m
| Portable and mobile RF communications equipment should beused no closer to
any part of product, including cables.than the recommended separation
distance calculated from the equation applicable to the frequency of the
transmitter.
Recommended separation distance
d=1.2
d=1.2
80 MHz∼800 MHz
d=2.3
800 MHz∼2.5 GHzWhere is the maximum output power rating of the transmitter in
watts (W) according to the transmitter manufacturer and d is the recommended
separation distance in meters (m).Field strengths from fixed RF transmitters,
as determined by an electromagnetic site survey.
d should be less than the compliance level in each frequency range.
Interference may occur in the vicinity of equipment marked with the following
symbol:
NOTE 1 Al 80 MHz and 800 MHz, the higher frequency range applies NOTE 2 These
guidelines may not apply in all situations Electromagnetic propagation is
affected by absorption and reflection from structures. objects and people.
a. Field strengths from fixed transmitters, such as base stations for radio Cellular/cordless) telephones and mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. The measured field strength in the location in which the product is used exceeds the applicable RF compliance level above, the product should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, Such as reorienting or relocating the product.
b. Over the frequency range 150 kHz to 80 MHz. field strengths should be less than 3 V/m
Recommended separation distances between portable and mobile RF
communications equipment and the
ME EQUIPMENT or ME SYSTEM
The product s intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or the user of the
product can help prevent electromagnetic interference by maintaining a
minimum distance between portable and mobile RF communications equipment
(transmitters) and the product as recommended below, according to the maximum
output power of the communications equipment
Im munity Test| IEC 60601 test level| Compliance level|
Electromagnetic environment
Rated maximum output power of transmitler/W| The spacing distance
corresponding to different frequencies of the transmitter/M
150kHz-80MHz
d = 1.2| 80MHz-800MHz
d=1.2| 800MHz-2.5GHz
d = 2.3
0.01| Not Applicable| 0.12| 0.23
0.1| Not Applicable| 0.38| 0.73
1| Not Applicable| 1.2| 2.3
10| Not Applicable| 3.8| 7.3
100| Not Applicable| 12| 23
For transmitters rated at a max’mum output power not listed above, the
recommended separation distance d in meters (m) can be estimated using the
equation applicable to the frequency of the transmitter. where P is the
maximum output power rating of the transmitter in watts (W) according to the
transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHZ the separation distance for the higher fre- quency range apples
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and refection from structures, objects and people.
- Description of hazardous substances
The name and content of harmful substances in the product
Component | Hazardous substance |
---|---|
Pb | Hg |
Shell | 0 |
PCBA | X |
Package material | 0 |
Alkaline battery | 0 |
Cell | Li battery |
Remark | This form has been prepared in accordance with SJ/T 11364. |
0: Indicates that the content of the harmful substance in all homo- geneous
materials of the component is specified limit of GB/T 26572 is as follows.
X: Indicates the content of the hazardous substance in at least one
homogeneous material of the component Exceed the limit stipulated by GB/T
26572.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>