beamZPro SB220IP Made Eazy User Manual
- June 1, 2024
- BeamzPro
Table of Contents
- beamZPro SB220IP Made Eazy
- Specifications
- Product Usage Instructions
- FAQ
- SAFETY INSTRUCTION
- UNPACKING IMSTRUCTION
- POWER SUPPLY
- RIGGING
- DMX512 CONTROL
- RDM CONTROL
- CLEANING
- PROTECTION CLASS IP65
- MAINTENANCE
- TROUBLESHOOTING
- DMX CHANNEL
- TECHNICAL SPECIFICATION
- ABOUT COMPANY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
beamZPro SB220IP Made Eazy
Specifications
- Model: SB220IP
- Version: 1.0
- Product Code : 150.456
Product Usage Instructions
Power Connection:
Before connecting the equipment to the power outlet, ensure that the mains
voltage and frequency match the specified values on the equipment. If there is
a voltage selection switch, verify compatibility before connecting to the
power outlet. Contact an electrician if the included power cord does not fit
your wall outlet.
Grounding and Safety:
Ensure that the unit is connected to a protected circuit with appropriate
electrical grounding to prevent risks of electrocution or fire. Do not
deactivate the protective ground of a power cord if equipped with an earthing
contact.
DMX Connection:
If using a standard DMX controller, connect the DMX output of the
controller to the DMX input of the first unit in a chain. Connect the output
of one unit to the input of the next unit until all units are connected.
Terminate the DMX line at the last unit with a 120 Ohm resistor between signal
(-) and signal (+) using an XLR connector.
Maintenance and Cleaning:
Regularly inspect and clean the unit to prevent dust buildup, which can
reduce light output and affect cooling efficiency. Consider environmental
factors like airborne dust, smoke machines, and ventilation airflow that may
accelerate dirt accumulation.Develop a cleaning schedule to ensure dirt is
removed promptly.
FAQ
-
What should I do if the power cord does not fit my wall outlet?
Contact an electrician for assistance if the included power cord or adapter does not match your wall outlet. -
How do I terminate the DMX line at the last unit?
Use an XLR connector to solder a 120 Ohm resistor between signal (-) and signal (+) and connect it to the DMX output of the last unit in the line.
SAFETY INSTRUCTION
WARNING: Before carrying out any operations with the unit, carefully read this instruction manual and keep it with care for future reference. It contains important information about the installation, usage and maintenance of the unit.
- Unpack and check carefully that there is no transportation damage before using the unit
- Please read these instructions carefully and follow the instructions.
- Observe all safety warnings. Never remove safety warnings or other information from the equipment.
- Be sure that no ventilation slots are blocked; otherwise the unit will overheated.
WARNING: Before connecting the equipment to the power outlet, first verify that the mains voltage and frequency match the values specified on the equipment. If the equipment has a voltage selection switch, connect the equipment to the power outlet only if the equipment values and the mains power values match. If the included power cord or power adapter does not fit in your wall outlet, contact your electrician.
- After connecting the unit, check all cables in order to prevent damage or accidents, e.g., due to tripping hazards.
- Make sure that the power cord is never crimped or damaged. Check the unit and the power cord from time to time.
- Always disconnect power from the mains, when unit is not used or before cleaning! Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
- Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike or before extended periods of disuse.
- Do not switch the unit on and off in short intervals.
- Do not connect the unit to a dimmerpack.
- Install the unit in a well ventilated place.
- Never place any material over the lens.
- Never let the sunlight lights directly to the front lens , even when the unit is not working.
- Always allow free air space of at least 50 cm around the unit for ventilation.
- Make sure that the area below the installation place is blocked when rigging, derigging or servicing the unit.
- For mounting height >100 cm, always fix the unit with an appropriate safety-rope. Fix the safety-rope at the correct fixation points only. The safety-rope must never be fixed at the transport handles!
- Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
- This unit is not designed for permanent operation. Consistent operation breaks will ensure that the unit will serve you for a long time without defects.
WARNING; If the power cord of the unit is equipped with an earthing contact, then it must be connected to an outlet with a protective ground. Never deactivate the protective ground of a power cord.
- Make sure that the unit is not exposed to extreme heator dust.
- Clean the unit using a dry cloth.
- Do not touch the unit bare-handed during its operation (housing becomes very hot). Allow the unit to cool for at least 5 minutes before handling.
- Do not expose this unit to flammable materials, fluids or gases.
- If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
- Never attempt to bypass the thermostatic switch or fuses.
- Do not dismantle or modify the unit.
- For replacement use fuses/bulb of same type and rating only.
- Repairs, servicing and electric connection must be carried out by a qualified technician.
- The ambient temperature must always be between -5° C and +45° C.
- If this unit is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void.
- Plastic bags must be kept out of reach of children.
- Unit must be installed out of the reach of children. Never leave the unit running unattended.
This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local Civic Office, your household waste disposal service or the shop where you purchased the product.
UNPACKING IMSTRUCTION
CAUTION Immediately upon receiving the product, carefully unpack the
carton, check the contents to ensure that all parts are present, and have been
received in good condition. Notify the shipper immediately and retain packing
material for inspection if any parts appear damage from shipping or the
package itself shows signs of mishandling. Save the package and all packing
materials. In the event that the product must be returned to the factory, it
is important that the product be returned in the original factory box and
packing.
If the unit has been exposed to drastic temperature fluctuation (e.g. after
transportation), do not switch it on immediately. The arising condensation
water might damage your unit. Leave the unit switched off until it has reached
room temperature.
POWER SUPPLY
- The label on the backside of the unit indicates the mains voltage to which it must be connected. Check that the mains voltage corresponds to this. Any other voltage than the one indicated may cause irreparable damage to the unit. The unit must also be connected directly to the mains voltage and no dimmer or adjustable power supply may be used.
- The unit has a powerconnector output on board. Depending on the local conditions several units can be linked by powerconnector in- and output. Connect a maximum of four (when using 230V/16A) units in a row. Use an approved three-core cable with a cross-section of at least 1.5 mm². The installation instructions of the manufacturer and the colour coding of the cable must be observed. Do not turn off the unit by turning the powerconnector but use the power on/off switch or schuko!
WARNING; Always connect the unit to a protected circuit (circuit breaker or fuse). Make sure the unit has an appropriate electrical ground to avoid the risk of electrocution or fire.
RIGGING
- The unit may be set up on a stable and even surface. By means of the fixing facilities of the baseplate, the unit can also be mounted upside down to a truss, see below picture. For fixing, certified clamps with correct save working load are required. According to the figure, the quick lock bolts of the omega brackets are placed into the openings provided in the base plate and turned clockwise until they lock (to the stop). The mounting place must be of sufficient stability and be able to support a weight of 10 times of the unit’s weight. Secure the unit with a safety cable so that it cannot fall down.
- When carrying out any installation, always comply European and national guidelines concerning rigging, truss and all other safety issues. Always let the installation checked out by an authorized dealer !
DMX512 CONTROL
If you are using a standard DMX controller, you can connect the DMX output of
the controller directly to the DMX input of the first unit in a DMX chain.
Always connect the output of one unit with the input of the next unit until
all units are connected.
CAUTION At the last unit, you must close the DMX line with a terminating
resistor. Take an XLR connector and solder a 120 Ohm resistor between signal
(-) and signal (+) and connect it to the DMX output of the last unit in the
line.
RDM CONTROL
- This unit can communicate using RDM (Remote Device Management) via DMX512. RDM is a bi-directional communication protocol for use in DMX512 control systems, it is the open standard for DMX512 configuration and status monitoring.
- The RDM protocol allows data packets to be inserted into a DMX512 line without affecting the existing non-RDM equipment. The system allows a controller or special RDM controller to send and receive commands from specific fixtures.
- The RDM function allows you, for example to remotely set the DMX start address of your fixtures. This is especially useful when the fixture is installed in an inaccessible location. Each unit has an RDM UID (unique identification number).
CLEANING
- The buildup of dust, dirt and other airborne particles will reduce the unit’s light output. It will also prevent the unit from cooling correctly, and this will reduce the unit’s lifetime. The rate of dirt buildup will vary depending on environmental factors such as airborne dust, use of smoke machines, airflow from ventilation systems, etc. The unit’s cooling fans will accelerate buildup, and any smoke particles that are present in the atmosphere will increase the tendency for dirt to clog.
- To get the best performance and lifetime from the unit, inspect it regularly and clean it as soon as you see signs of dirt buildup.
- Assess the operating environment each time you begin to use the unit. In dusty or smoky conditions, inspect the unit after a few hours and check it frequently the unit may attract dirt faster than you expect. Draw up a cleaning schedule that will make sure that dirt is removed before it can build up.
- Use the following guidelines:
- Disconnect the unit from power and allow it to cool completely before cleaning.
- Do not use solvents, abrasives or any other aggressive product to clean the unit.
- Vacuum or use low-pressure compressed air to remove dust and loose particles from surfaces and air vents. Prevent the blades of cooling fans from turning before you aim a vacuum or air jet at the fan, or you may spin the fan too fast and damage it.
- Clean glass components by wiping gently with a soft, clean, lint-free cloth moistened with a weak detergent solution. Put the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
- Dry the unit with a soft, clean, lint-free cloth or low-pressure compressed air before reapplying power.
PROTECTION CLASS IP65
Units with protection class IP65 are dust-tight and completely protected against contact (first code number). They are also protected against splash water from any angle (second code digit). That is why this unit can also be used out‐ doors. Events units are generally only designed for temporary use however (event lighting) and not for permanent use outdoors. The specified protection class does not make a statement about the weather resistance of the units (resistance to changing ambient conditions as well as against the effects of sunlight and UV rays). The seals and screw connections of the units must be checked regularly to ensure a fault-free operation.
MAINTENANCE
This unit is virtually maintenance-free, but you should check the unit regularly for mechanical and electrical aspects. Assess the operating environment and establish an inspection and cleaning schedule that follows the guidelines below:
- Disconnect the unit from the power supply and allow it to cool completely before inspecting and cleaning.
- Check that the screws and bolts used to install the unit are securely tightened and free from corrosion.
- Check the housing, fixing points and installation points, they must not show any signs of deformation, wear or fatigue.
- Check the mechanically moving parts, these must not show any signs of wear or fatigue.
- Check the electrical power and signal cables, they must not show any damage or fatigue.
- Do not use solvents, abrasives or other aggressive products to clean the unit.
- Wipe the unit and clean the glass plate with a soft, clean, lint-free cloth moistened with a weak cleaning solution. Place the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
- Dry the unit, connectors and contacts with a soft, clean, lint-free cloth or low-pressure compressed air before re-powering the unit.
TROUBLESHOOTING
The checklist below may help you troubleshoot in the unlikely event that a problem occurs while using the product:
| |
---|---|---
No response from unit.| No power to unit.| Check that power is turned on.
Check cables and connections.
| Fuse blown or internal fault.| Replace mean fuse or contact Beamz support
or Beamz authorized service partner. Do not remove base or yoke covers. Do not
attempt to replace a fuse or carry out any repairs or service that are not
described in this User Manual unless you have both authorization from Beamz
support or Beamz authorized service partner.
Unit resets correctly but does not respond (or does not respond correctly) to
the controller.| The controller is not connected.| Connect controller.
Bad DMX-line.| Inspect connections and cables. Correct poor connections.
Repair or replace damaged cables.
| DMX-line has no end resistance.| Insert DMX terminator plug in DMX output
socket of last unit on DMX-line.
| Incorrect unit addressing.| Check unit address and DMX mode settings.
| A unit is defective and is disturbing data transmission on the DMX-line.|
Unplug DMX IN and OUT connectors and connect them directly together to bypass
one unit at a time until normal operation is regained. Have defective unit
serviced by an authorized
technician.
| Pin 2 and 3 are reversed in XLR connection.| Inspect connections and
cables. Install a phase- reversing cable between the units or swap pin 2 and 3
in the unit, that behaves erratically.
Error after unit reset.| Effect requires mechanical adjustment.| Check unit’s
software version and error messages for more information. Contact Beamz
support or Beamz authorized service partner.
Light output cuts out intermittently.| Unit too hot.| Allow unit to cool.
Reduce ambient temperature. Ensure free airflow around unit.
Clean unit if necessary.
| LEDs damaged.| Disconnect unit and contact Beamz support or Beamz
authorized service partner.
| The power supply settings do not match local AC voltage and frequency.|
Disconnect unit. Check settings and correct if necessary.
DMX CHANNEL
1 CHANNEL
| | | |
---|---|---|---|---
| 1| 000-255| Dimming all LEDs tungsfen function|
3 CHANNEL
| |
---|---|---
1| 000-255| Master dimming
2| 000-255| Dimming head 1 tungsten function
3| 000-255| Dimming head 2 tungsten function
4 CHANNEL
| |
---|---|---
1| 000-255| Dimming head 1 warm white
2| 000-255| Dimming head 1 amber
3| 000-255| Dimming head 2 warm white
4| 000-255| Dimming head 2 amber
8 CHANNEL
| |
---|---|---
1| 000-255| Master dimmer
2| 000-255| Dimming head 1 warm white
3| 000-255| Dimming head 1 amber
4| 000-255| Dimming head 2 warm white
5| 000-255| Dimming head 2 amber
6| 000-004| No function
005-255| Strobe from slow to fast
| 000-50| No Function
7| 051-100| Jump mode from slow to fast
101-150| Fade mode from slow to fast
| 151-255| Pulse mode from slow to fast
8| 000-255| If CH7=0~50, speed for dimming
If CH7=51~255, speed for macro from slow to fast
TECHNICAL SPECIFICATION
- Product colour Black
- Light source 2-in-1 LED
- LED colours Amber, White
- Quantity of LEDs 2
- Beam angle 48°
- Field angle 74°
- Illuminance 17.300 lx @ 1m
- Flash rate per second 1 – 25Hz
- DMX channels 1, 3, 4, 8
- DMX connection 3-pin and 5-pin XLR
- Modes Automatic programs , DMX, Manual, Master/Slave
- IP rating IP65
- Cooling Convection
- Display LED
- Power consumption 2.56 – 1.4A
- Power supply 100-240VAC 50/60Hz
- Dimensions (L x W x H) 405 x 200 x 310mm
- Weight 7,60
- Included accessories Mounting bracket, Power cable
ABOUT COMPANY
- European Union
- Tronios B.V.,
- Bedrijvenpark Twente Noord 18,
- 7602KR Almelo, The Netherlands
- United Kingdom
- Tronios Ltd.,
- 130 Harley Street,
- London W1G 7JU, United Kingdom
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>