trucorp AA51100 AirSim Bronchi User Manual

June 3, 2024
trucorp

AA51100 AirSim Bronchi
User Manual
trucorp AA51100 AirSim Bronchi

AA51100 AirSim Bronchi

An innovative and durable solution for realistic airway management training
The AirSim® model features the uniquely constructed AirSim® airway for realistic feedback during airway management procedures. Visually and anatomically correct, the nasal cavity and airway include important internal landmarks for training in endo-tracheal and nasotracheal intubations.

Product specifications

Product Code: AA11100
AirSim weight: Approx. 3.3kg
Full shipment weight: Approx. 4kg
Full shipment dimensions: 46 x 26 x 33cm

Package contents

  • 1 AirSim ready-to-use (AA11100)
  • 1 AirSim carrier case (ABAG01)
  • 100ml bottle of lubrication (TL001)
  • 2 sets of adhesive pads (attachable to suction cups for increased stability if required)

Recommended equipment sizes

  • 7.0-7.5mm ID for nasal intubation
  • 8.0-9.0mm ID for oral intubation
  • Sizes 3-5 for LMA laryngeal masks
  • Similar respective sizes for other supraglottic devices

Initial set-up information

  • Gently remove the model from the carrying case and remove the protective foam placed under the manikin head
  • Secure the manikin to a suitable surface by adjusting the screw on the suction cups (the surface must be non-porous to ensure sufficient suction)
  • Optional: Adhesive pads are provided with the model for increased stability if required. This is particularly useful when the product is not on an ideal surface for suction cups to be effective. Simply peel the cover from the pad to locate the adhesive area and attach it to the suction cups.
  • Loosen the neck locks to provide easier head movement if required. Re-tighten the neck lock again once the head is in the desired position
  • Check the volume of air in the tongue is sufficient, it can be inflated or deflated by a syringe to adjust the difficulty during intubation if desired
  • Please ensure two lung bags and one stomach bag are attached to the airway and esophagus respectively
  • Spray generous amounts of lubrication provided with the model (TL001) on the airway and equipment prior to use

List of procedures facilitated by the AirSim

  • Single nasotracheal intubation
  • Naso gastric tube insertion
  • Full range of supraglottic devices
  • Direct laryngoscopy
  • Endotracheal tube insertion
  • Awake fiber optic examination
  • Single lung isolation techniques
  • Combi tube insertion

Care and maintenance

Store in clean, dry conditions away from heat and direct sunlight; avoid contact with metals, solvents, oils or greases and strong detergents. When the product is not in use please store in the black carrier case provided.
Thoroughly wash the AirSim airway in warm water. Please use warm soapy water or something similar until all visible foreign matter and residue is removed.
Mild detergents or enzymatic cleaning agents may be used on the airway in accordance with the manufacturer’s instructions and at the proper dilution. The detergent must not contain skin or mucous membrane irritants.
Please do not use any of the following when cleaning the AirSim product range

  • Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g. Cidex®),
  • Ethylene oxide, phenol-based cleaners, or iodine-containing cleaners In response to the recent COVID-19 pandemic, we recommend this additional step to ensure the product is fully sanitized:

Use alcohol spray (minimum 75%) and wipe off. Repeat this 3-4 times to ensure to kill of the virus is complete. This method can be used on both the silicone skin and the latex airway.

Warranty

TruCorp warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 1-year from the date of delivery.
This ensures that our customers receive maximum coverage on each product. If the unit should malfunction it must be returned to the factory for evaluation. Upon examination by TruCorp, if the unit is found to be defective it will be repaired or replaced at no charge.
However, this warranty is VOID, if; the unit shows evidence of having been tampered with or shows evidence of having been damaged by excessive heat, the use of sharp instruments, misapplication, misuse, or other operating conditions outside of TruCorp’s control.
Components that wear or are damaged by misuse are not warranted and will be charged if a repair has been approved.

Please direct all warranty and repair inquiries to:

TruCorp Ltd
33 Waringstown Road
Lurgan, Co. Armagh
BT66 7HH
N. Ireland
[email protected]
Tel: +44 (0) 28 3888 2714

Documents / Resources

| trucorp AA51100 AirSim Bronchi [pdf] User Manual
AA51100 AirSim Bronchi, AA51100, AirSim Bronchi, Bronchi
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

trucorp User Manuals

Related Manuals