HILTI HIT-HY 200-A Injection Mortar Instruction Manual

June 1, 2024
HILTI

HILTI HIT-HY 200-A Injection Mortar

HILTI-HIT-HY-200-A-Injection-Mortar-PRODUCT

Product Specifications

  • Model: HIT-Z/HIT-Z-F/HIT-Z-R
  • Length Identification: D, E, G, H, J, F, I, M, K, N, P, S, T, V, Q, U, W
  • Anchor Sizes: M8, M10, M12, M16, M20
  • Installation Torque (Tinst): Refer to the provided table for specific values
  • Application: Bonded injection anchor for use in concrete

Product Usage Instructions

Installation Process

  1. Identify the appropriate anchor size based on your application requirements.
  2. Drill the hole in the concrete substrate to the specified diameter (d).
  3. Clean the hole thoroughly to ensure proper adhesion.
  4. Insert the anchor into the hole and apply the recommended installation torque (Tinst).
  5. Allow the adhesive to cure as per the instructions provided.
  6. Verify the anchor is securely in place before applying any loads.

Safety Precautions

  • Always wear appropriate personal protective equipment during installation.
  • Handle the adhesive and anchors with care to prevent any accidents.
  • Ensure proper ventilation when working with adhesives in enclosed spaces.

Frequently Asked Questions (FAQ):

Q: What is the recommended torque for installing HIT-Z and HIT-Z-F anchors?

  • A: The recommended installation torque can be found in the provided table. It varies based on the anchor size and model.

Q: How long does the adhesive take to cure?

  • A: The curing time for the adhesive depends on various factors such as temperature and humidity. Refer to the product instructions for specific curing times.

Q: Where can I find more information about the product and its specifications?

  • A: You can visit www.hilti.group or refer to the detailed product manual for comprehensive information regarding the product specifications and usage guidelines.

Dimension

HILTI-HIT-HY-200-A-Injection-Mortar-FIG-1

HOW TO USE

HILTI-HIT-HY-200-A-Injection-Mortar-FIG-2 HILTI-HIT-HY-200-A-Injection-Mortar-FIG-3

Specification

HIT-Z HIT-Z-R length identification code
M8 × 80 D
M8 × 100 E
M8 × 120 G
M10 × 95 E
M10 × 115 G
M10 × 135 H
M10 × 160 J
M12 × 105 F
M12 × 140 I
M12 × 155 J
M12 × 196 M
M16 × 155 J
M16 × 175 K
M16 × 205 N
M16 × 240 P
M16 × 280 S
M16 × 330 T
M16 × 380 V
M20 × 215 N
M20 × 250 Q
M20 × 300 S
M20 × 350 U
M20 × 400 W
⌀ d (mm) M8 M10 M12 M16 M20
d0 10 12 14 18 22
df1 11 14 16 20 24
df2 9 12 14 18 22
hef 60 … 96 60 … 120 60 … 144 96 … 192 100 … 220
lp ≥ 12 ≥ 13 ≥ 16 ≥ 21 ≥ 24
human 1 human 1 = hnom + 60 mm human 1 = hnom + 100 mm
human 2 hmin 2 = hnom + 30 mm ≥ 100 mm human 2 = hnom + 45 mm

human 2
fix| fix = l – hnom – lp
Tinst (Nm) HIT-Z / HIT- Z-F| 10| 25| 40| 80| 150
Tinst (Nm) HIT-Z-R| 30| 55| 75| 155| 215
SW| 13| 17| 19| 24| 30

Contact Service


23
Hilti AG LI-9494 Schaan Hilti Werke
2873-CPR-201-14
ETA-12/0006
Notified body 2873
EAD 330499-01-0601
www.hilti.group

23
Hilti AG LI-9494 Schaan Hilti Werke
2873-CPR-201-15
ETA-12/0028
Notified body 2873
EAD 330499-01-0601
www.hilti.group

23
Hilti AG LI-9494 Schaan Hilti Werke
2873-CPR-201-59
ETA-19/0632
Notified body 2873
EAD 330499-01-0601
www.hilti.group

24
Hilti Corporation, LI-9494 Schaan Hilti Plants
UK 0836-CPR-22/P6574
UKTA-22/6573
Approved body 0836
UKAD 330499-01-0601
Bonded injection anchor for use in concrete