HILTI HIT-HY 200-A Injection Mortar Instruction Manual
- June 1, 2024
- HILTI
Table of Contents
HILTI HIT-HY 200-A Injection Mortar
Product Specifications
- Model: HIT-Z/HIT-Z-F/HIT-Z-R
- Length Identification: D, E, G, H, J, F, I, M, K, N, P, S, T, V, Q, U, W
- Anchor Sizes: M8, M10, M12, M16, M20
- Installation Torque (Tinst): Refer to the provided table for specific values
- Application: Bonded injection anchor for use in concrete
Product Usage Instructions
Installation Process
- Identify the appropriate anchor size based on your application requirements.
- Drill the hole in the concrete substrate to the specified diameter (d).
- Clean the hole thoroughly to ensure proper adhesion.
- Insert the anchor into the hole and apply the recommended installation torque (Tinst).
- Allow the adhesive to cure as per the instructions provided.
- Verify the anchor is securely in place before applying any loads.
Safety Precautions
- Always wear appropriate personal protective equipment during installation.
- Handle the adhesive and anchors with care to prevent any accidents.
- Ensure proper ventilation when working with adhesives in enclosed spaces.
Frequently Asked Questions (FAQ):
Q: What is the recommended torque for installing HIT-Z and HIT-Z-F anchors?
- A: The recommended installation torque can be found in the provided table. It varies based on the anchor size and model.
Q: How long does the adhesive take to cure?
- A: The curing time for the adhesive depends on various factors such as temperature and humidity. Refer to the product instructions for specific curing times.
Q: Where can I find more information about the product and its specifications?
- A: You can visit www.hilti.group or refer to the detailed product manual for comprehensive information regarding the product specifications and usage guidelines.
Dimension
HOW TO USE
Specification
HIT-Z HIT-Z-R | length identification code |
---|---|
M8 × 80 | D |
M8 × 100 | E |
M8 × 120 | G |
M10 × 95 | E |
M10 × 115 | G |
M10 × 135 | H |
M10 × 160 | J |
M12 × 105 | F |
M12 × 140 | I |
M12 × 155 | J |
M12 × 196 | M |
M16 × 155 | J |
M16 × 175 | K |
M16 × 205 | N |
M16 × 240 | P |
M16 × 280 | S |
M16 × 330 | T |
M16 × 380 | V |
M20 × 215 | N |
M20 × 250 | Q |
M20 × 300 | S |
M20 × 350 | U |
M20 × 400 | W |
⌀ d (mm) | M8 | M10 | M12 | M16 | M20 |
---|---|---|---|---|---|
d0 | 10 | 12 | 14 | 18 | 22 |
df1 | 11 | 14 | 16 | 20 | 24 |
df2 | 9 | 12 | 14 | 18 | 22 |
hef | 60 … 96 | 60 … 120 | 60 … 144 | 96 … 192 | 100 … 220 |
lp | ≥ 12 | ≥ 13 | ≥ 16 | ≥ 21 | ≥ 24 |
human 1 | human 1 = hnom + 60 mm | human 1 = hnom + 100 mm | |||
human 2 | hmin 2 = hnom + 30 mm ≥ 100 mm | human 2 = hnom + 45 mm |
human 2
fix| fix = l – hnom – lp
Tinst (Nm) HIT-Z / HIT- Z-F| 10| 25| 40| 80| 150
Tinst (Nm) HIT-Z-R| 30| 55| 75| 155| 215
SW| 13| 17| 19| 24| 30
Contact Service
23
Hilti AG LI-9494 Schaan Hilti Werke
2873-CPR-201-14
ETA-12/0006
Notified body 2873
EAD 330499-01-0601
www.hilti.group
23
Hilti AG LI-9494 Schaan Hilti Werke
2873-CPR-201-15
ETA-12/0028
Notified body 2873
EAD 330499-01-0601
www.hilti.group
23
Hilti AG LI-9494 Schaan Hilti Werke
2873-CPR-201-59
ETA-19/0632
Notified body 2873
EAD 330499-01-0601
www.hilti.group
24
Hilti Corporation, LI-9494 Schaan Hilti Plants
UK 0836-CPR-22/P6574
UKTA-22/6573
Approved body 0836
UKAD 330499-01-0601
Bonded injection anchor for use in concrete