LINGXIAO Relaax130-VS Variable Speed Pumps Instruction Manual
- June 1, 2024
- LINGXIAO
Table of Contents
Relaax130-VS Variable Speed Pumps
Specifications
- Model Options: Relaax130-VS, Relaax220-VS, Relaax390-VS
- Variable Speed Pumps
- Control: Keypad
- External Control: RS485 Signal Cable
Product Usage Instructions
Installation
1. Location:
Choose a suitable location for the pump ensuring proper
ventilation and accessibility for maintenance.
2. Piping:
Connect the pump to the piping system following the provided
guidelines to ensure proper flow.
3. Fitting and Valves:
Install necessary fittings and valves to control the flow and
pressure of the water.
4. Electrical Installation:
Follow the electrical installation instructions carefully to
ensure safe and proper connection.
Operation
1. Setting the Clock:
Adjust the clock on the pump according to your local time for
accurate scheduling.
2. Programming an Operation Schedule:
Set the speed and running time in Auto Mode for efficient
operation.
Maintenance
1. Cleaning the pump strainer & skimmer basket:
Regularly clean the strainer and basket to maintain optimal pump
performance.
2. Winterizing:
Prepare the pump for winter by following the recommended
winterizing procedures.
Troubleshooting
If you encounter any issues with the pump, refer to the
troubleshooting section in the manual for guidance on identifying
and resolving problems.
FAQ
Q: How do I reset the pump to factory default settings?
A: To reset the pump to factory default settings, follow the
steps outlined in the manual under the “Reset factory default
setting” section.
Variable Speed Pumps Instruction Manual
Relaax130-VS
Relaax220-VS
Relaax390-VS
READ CAREFULLY AND FOLLOW THIS INSTRUCTION
KEEP THIS INSTRUCTION FOR FUTURE REFERENCE
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
TABLE OF CONTENTS
Important Warning and Safety Instructions —————————– 1~2
Overview ——————————————————————————- 3
Pump Features
3
Drive Overview
3
Keypad Overview ——————————————————————– 4
Installation —————————————————————————– 5
Location
5
Piping
5
Fitting and Valves
5
Electrical Installation
5
Wiring Position ———————————————————————- 6
Wiring position
6
Grounding
6
Bonding
6
External Control Via RS485 Signal Cable ———————————– 7
RS485 signal cable connection
7
Operation —————————————————————————— 8
Setting the Clock
8
Programming an Operation Schedule
8
1. Program Speed and Running time in Auto Mode
8
2. Set priming, Quick clean & exhaust time and speed
8
3. Switch from Auto Mode to Manual Mode
8
Reset factory default setting
9
Lock / Unlock the keyboard
9
Turn off/ turn on button sound
9
Button cell replcement
9
Priming
9
Maintenance ————————————————————————- 10
Cleaning the pump strainer & skimmer basket
10
Winterizing
10
Pump care
10
Restart the pump
10
Trouble shooting ——————————————————————- 11
Installation Diagram and Technical Data ———————————– 12
Performance Curve and Installation Size ———————————- 13
Warranty & Contact Us ———————————————————- 14
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
ALARM Installer: This manual offers important information about the
installation, operation and safe use of this pump. This manual should be given
to the owner and/or operator of this pump after installation or left on or
near the pump.
ALARM User: This manual provides important information that will help you in
operating and maintaining this pump. Please keep it for future reference.
Please read and follow all instructions below.
Please pay attention to the below symbols. When you meet them in this manual
or on your system, please be careful for the potential personal injury.
DANGER
Cautions hazards which can lead to death, serious personal injury, or major property damage if ignored.
WARNING
Cautions hazards which can lead to death, serious personal injury, or major property damage if ignored.
CAUTION
Cautions hazards which can lead to death, serious personal injury, or major property damage if ignored.
NOTE
Special instructions that are not related to hazards are indicated.
All safety instructions in this manual and on equipment should be carefully read and followed. Make sure safety labels are in good condition, replace them if they are damaged or missing.
The following basic safety precautions should always be followed when installing and using this electrical equipment:
DANGER
SERIOUS BODILY INJURIES OR DEATH CAN RESULT FROM FAILURE TO FOLLOW ALL
INSTRUCTIONS. BEFORE USING THIS PUMP, POOL OPERATORS
AND OWNERS SHOULD READ THESE WARNINGS AND ALL
INSTRUCTIONS IN THE OWNER’S MANUAL.
A POOL OWNER MUST KEEP THESE WARNINGS AND THE OWN-
ER’S MANUAL.
WARNING Children are NOT allowed to use this product.
WARNING
BEWARE OF ELECTRICAL SHOCK. In order to prevent a ground fault from occurring in this unit, a
ground fault circuit interrupter (GFCI) must be installed on its supply
circuit. The installer should install an appropriate GFCI and test it regular-
ly. When you press the test button, the power supply should be interrupt-
ed, and when you press the reset button, the power should return. If this
is not the case, the GFCI is defective. It is possible that an electric shock
may occur if the GFCI interrupts power to a pump without the test button
being pressed. Unplug the pump and contact a qualified electrician to
replace the GFCI. Never use a pump with a defective GFCI. Always test
the GFCI before use.
CAUTION
Unless otherwise noted, this pump is intended for use with permanent swimming pools and hot tubs
and spas if they are appropriately marked. It should not be used with stor-
able pools.
General Warnings:
· Never open the enclosure of the drive or motor. This unit has a capacitor
bank that retains a 230 VAC charge even if the power is off.
· There is no submersible feature on the pump. · Pump high flow rates
performance will be limited by older or questionable
equipment when installed and programmed. · Depending on the country, state,
and local municipality, there may be
differing requirements for electrical connections. Follow all local codes and
ordinances as well as the National Electrical Code when installing equipment.
· Disconnect the main circuit of the pump before servicing it. · Unless
supervised or instructed by a person responsible for their safety, this
appliance is not intended for use by individuals (including children) with
reduced physical, mental, or sensory abilities, or without experience and
knowledge.
DANGER
HAZARDS RELATED TO SUCTION ENTRAPMENT: stay away from all suction outlets and the main drain!
in addition, this pump is not equipped with safety vacuum release system
(SVRS) protection. in order to prevent accidents, please prevent your body
or hair from being sucked by the water pump inlet.
At the main water line, the pump produces a strong vacuum and a high level of suction. Adults and children can be trapped underwater if they are near drains, loose or broken drain covers or grates. A swimming pool or spa covered with non-approved materials or one with a missing, cracked, or broken cover can cause limb entrapment, hair entanglement, body entrapment, evisceration, and/or death.
There are several causes of suction at drains and outlets:
Limb Entrapment: A mechanical bind or swelling occurs when a limb is sucked
into an opening. Whenever there is a problem with a drain cover, such as a
broken, loose, cracked or improperly fastened one, this hazard occurs. Hair
Entanglement: The tangle or knotting of the swimmer’s hair in the drain cover,
resulting in the swimmer being trapped underwater. When the flow rating of the
cover is too low for the pump or pumps, this hazard may arise. Body
Entrapment: When a portion of the swimmer’s body is trapped under the drain
cover. When the drain cover is damaged, missing, or not rated for the pump,
this hazard arises. Evisceration/Disembowelment: A suction from an open pool
(usually a child’s wading pool) or spa outlet causes severe intestinal damage
to a person. This hazard is present when the drain cover is missing, loose,
cracked, or not properly secured. Mechanical Entrapment: When jewelry,
swimsuit, hair decorations, finger, toe or knuckle is caught in an opening of
an outlet or drain cover. If the drain cover is missing, broken, loose,
cracked, or not properly secured, this hazard exists.
NOTE: THE PLUMBING FOR SUCTION MUST BE INSTALLED IN ACCORDANCE WITH THE LATEST
LOCAL AND NATIONAL CODES.
WARNING
IN ORDER TO REDUCE INJURY RISKS FROM SUCTION ENTRAPMENT HAZARDS:
· Each drain must be equipped with an ANSI/ASME A112.19.8
approved anti-entrapment suction cover.
· Each suction cover should be installed minimum three (3′) feet
apart measuring between the closest points.
· Check all covers for cracks, damage, and advanced weathering
regularly.
· Replace a cover if it becomes loose, cracked, damaged, broken,
or missing.
· Replace drain covers as necessary. Drain covers deteriorate
over time due to exposure to sunlight and weather.
· Avoid getting close to any suction cover, pool drain, or outlet with
your hair, limbs, or body.
· Suction outlets can be disabled or reset into return inlets
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-1-
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
WARNING
A high level of suction can be generated by the pump in the plumbing system’s suction side. The high
level of suction can pose a threat to those in close proximity to the suction
openings. This high vacuum can cause serious injuries or cause people to
become trapped and drown. Swimming pool suction plumbing must be
installed according to the latest national and local codes.
WARNING
A clearly identified emergency shut-off switch for the pump should be located in a highly visible location.
Ensure that all users know where it is located and how to use it in case of
an emergency.
The Virginia Graeme Baker (VGB) Pool and Spa Safety Act establishes new
requirements for commercial swimming pool and spas owners and
operators.
On or after December 19, 2008, commercial pools and spas must use: A multiple main drain system without isolation capability with suction outlet covers complying with ASME/ANSI A112.19.8a Suction Fittings for Swimming Pools, Wading Pools, Spas, and Hot Tubs and either: (1) Safety vacuum release systems (SVRS) that meet ASME/ANSI A112.19.17 Manufactured Safety Vacuum Release systems (SVRS) for Residential and Commercial Swimming Pools, Spas, Hot Tubs, and Wading Pool Suction Systems, or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems (SVRS) for Swimming Pools, Spas and Hot Tubs (2) Suction-limiting vents that have been properly designed and tested (3) System for shutting off pumps automatically
Information about Installation: · There is a requirement that all work be performed by a qualified service professional and in accordance with all national, state, and local regulations. · Ensure that electrical components are properly drained in the compartment. · There are several models of pump included in these instructions, so some may not apply to a specific model. All models are geared toward swimming pool use. If the pump is properly sized for the specific application and properly installed, it will function correctly.
WARNING
The improper size, installation, or use of pumps in applications for which they were not designed can
result in serious personal injury or death. There are a number of risks
involved, including electric shocks, fires, flooding, suction entrapment,
severe injury to others or property damage as a result of structural failures
in pumps or other system components.
Pumps and replacement motors that are single speed and one (1) Total HP or greater cannot be sold, offered for sale, or installed in a residential pool for filtration use in California, Title 20 CCR sections 1601-1609.
Pools and spas constructed before December 19, 2008, with a single submerged suction outlet, must use a suction outlet cover that meets ASME/ANSI A112.19.8a or either: (A) A SVRS compatible to ASME/ANSI A112.19.17 and/or ASTM F2387,or (B) Suction-limiting vents that have been properly designed and tested or (C) System for shutting off pumps automatically, or (D) Submerged outlets can be disabled or (E) Reconfiguration of suction outlets into return inlets is required.
CAUTION
Installing electrical controls at the equipment pad (ON/OFF switches, timers, and automation load
centers)
Ensure that all electrical controls are installed at the equipment pad,
including switches, timers, and control systems. To prevent the user from
putting his/her body over or near a pump strainer lid, filter lid, or valve
closure when starting, shutting down, or servicing a pump or filter.
During system start-up, shutdown, or servicing of the filter, the user should
be able to stand far enough away from the filter and pump.
DANGER
When starting up, keep the filter and pump away from your body.
When parts of a circulating system are serviced (i.e. locking rings, pumps,
filters, valves, etc.) air can enter and pressurize the system. It is possible
for the pump housing cover, filter lid, and valves to violently separate when
subjected to pressurized air. You must secure the strainer cover and filter
tank lid to prevent violent separation.
When turning on or starting up the pump, keep all circulation equipment
clear of you. You should note the filter pressure before servicing the
equipment. Make sure that the pump controls are set so that it cannot start
inadvertently during service.
IMPORTANT: Ensure that the filter manual air relief valve is in the open position and wait for all pressure in the system to be released. Open the manual air relief valve fully and put all system valves in the “open” position before starting the system. Make sure you stand clear of any equipment when starting the system. IMPORTANT: If the filter pressure gauge is higher than the pre-service condition, don’t close the manual air relief valve until all pressure has been released from the valve and a steady stream of water appears.
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-2-
OVERVIEW
Pump Features:
· Energy Star 3.1, DOE, CEC Certified. · Larger strainer basket with
transparent pot lid for easy inspection. · Handle for easy carrying. · Supper
quiet operation as low as 42 decibel. · ANSI standard fittings (1.5″ OR 2″). ·
Quick & easy operation for In ground Self-priming pumps (Relaax220-VS
& Relaax390-VS) & above ground swimming pool pump (Relaax130-VS). ·
Programable operation schedule to save energy consumption up to 80%. · NSF 50
Certified for Relaax220-VS, Relaax390-VS.
Drive Overview:
The pump is equipped with a variable speed, high efficiency motor that
provides flexibility in terms of motor speed. There are settings for duration
and intensity. Pumps are designed to run continuously maintaining a sanitary
environment at the lowest possible speed, minimizing the consumption of energy
while protecting the environment.
DANGER
Pump is rated for 115/208-230 Volts nominal, Only for pool pumps. Connecting incorrect voltage or use in
other applications may cause damage, personal injury or damage to
equipment.
The integrated electronics interface controls the speed and the duration of the run. Pumps are capable of running speed ranges from 450 to 3450 RPM. The pump is designed to operate within the voltage range of 115/280-230 volts at either 50 or 60Hz input frequency.
It is usually best to set the pump to the lowest setting possible in order to minimize energy consumption; the fastest speed for the longest duration leads to more consumption of energy. However, the optimal settings can be influenced by a number of factors, such as the size of the pool, environmental conditions and the number of water features. Pumps can be programmed according to adapt to your specific needs.
Drive Features:
· User-friendly interface · Enclosures that are UV and rain-proof · Time
schedule onboard · Priming & Quick Clean mode can be Programmed · Display and
retention of pump alarms · Power input: 115/208-230V, 50 & 60Hz · Power
limiting protection circuit · A 24-hour service is available. In case of power
outages, the clock will be
retained · Lockout mode for the keypad
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-3-
KEYPAD OVERVIEW
Communication indicator
Power indicator
Running indicator light
Increase key Decrease key
Run/Stop key
System time Tab/Toggle key
Rotating speed
Fault Run Manual Auto
Start and end time
Speed
Keypad
Speed gear key
LCD Screen
WARNING
If power is connected to the motor, it is important to be aware that pressing any of the buttons referred to in this section could result in the motor starting. This could
lead to potential danger in the form of personal injury or damage to equipment if the risk is not taken into
account.
Key symbol
Name Run/Stop key
Function Description Control the start-up and shutdown of the pump.
Speed gear key
In automatic mode, you can check the speed gear.
In manual mode, the speed gear can be selected.
Press and hold the button for 3 seconds to enter the setting
state, press / /
set speed and running time
(running tiem can only be set in automatic mode [ ]).
NOTE 1: Every time when the pump is started, it will run at a speed of 3450r/min for 10 minutes (the factory default is 3450r/min, 10min), and the home page of the screen will display a countdown. After the countdown ends, it will run according to the predetermined plan or perform manual operation; In the Auto Mode, hold button for 3 seconds, speed number(3450) will blink and use / to set priming speed; Then press button and the priming time will blink, Then use / button to set priming time.
Quick clean button
In automatic mode, you can view the quick cleaning gear. In manual mode, the
quick cleaning gear can be selected. Press and hold the button for 3 seconds
to enter the setting state press / / , set speed and running time
(running time can only be set in automatic mode [ ]) [NOTE 1].
Tab/toggle key
Display running wattage. In the setting state, you can select speed, time (hour, minute) in turn. Press and hold the button for 3 seconds to enter the system time setting.
Increase key Speed increase/time increase.
NOTE 2: In the setting state, if there is no button operation for 6
seconds, it will exit the setting state and save the
settings. The operation cycle does not exceed 24
hours.
Decrease key Speed reduction/time reduction.
Key combination
In the off state, press the
button at the same time
and hold for 3 seconds to restore the factory settings.
In the off state, press and hold the + buttons for 3 seconds at the same time, the LCD screen will switch between manual mode and automatic mode, and the corresponding icon will be displayed.
Key combination
The controller displays the home page, and press the + key for 3 seconds at
the same time to lock/unlock the keyboard.
The controller displays the home page, press the + button for 3 seconds at the
same time to turn on/off the button sound.
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-4-
INSTALLATION
INSTALLATION:
It is essential to only use a qualified professional to ensure a safe and
successful installation. Failure to follow this instructions correctly could
result in serious injury or property damage.
LOCATION:
NOTE: It is important to note that when installing this pump, it should not be
placed within an outer enclosure or underneath the skirt of a hot tub or spa,
unless it is marked accordingly. Note: it is essential to ensure that the pump
is mechanically secured to the equipment pad for proper functioning.
Make sure the pump can match the below requirements: 1. It is important to
install the pump as close to the pool or spa as possible.
This will reduce friction loss and improve the overall efficiency of the pump.
To further reduce friction loss and improve efficiency, it is recom mended to
use short, direct suction and return piping. 2. It is important to ensure that
there is a minimum of 5′ (1.5 m) between the inside wall of the pool and spa
and any other structures. For any Canadian installations, a minimum of 9.8′ (3
m) from the inside wall of the pool must be maintained. 3. It is important to
install the pump at least 3′ (0.9 m) away from the heater outlet. 4. It is
important to remember to not install the self-priming pump more than 8′ (2.6
m) above the water level. 5. it is important to choose a well-ventilated
location that is protected from excess moisture. 6. Please keep at least 3″
from rear of motor and 6″ from the top of control pad for easy maintenance and
repair.
Fittings and Valves:
1. 90° elbows directly into pump intake & discharge are NOT allowed. 2.
Installing gate valves on suction and discharge pipes is an important
part of any flooded suction system, as it allows for maintenance and other
activities to be carried out more easily. However, the suction gate valve
should not be placed any closer than five times the diameter of the suction
pipe. 3. Using a check valve in the discharge line is highly recommended for
any application of this pump where there is significant plumbing height after
the pump. 4. It is important to install check valves when plumbing in parallel
with another pump to ensure proper functioning. Check valves help to prevent
reverse rotation of the impeller and motor.
Electrical Installation:
DANGER
READ THIS INSTRUCTION BEFORE OPERATION RISK OF ELECTRICAL SHOCK OR ELECTROCU-
TION.
It is essential that the pump MUST be installed by a qualified and licensed
electrician, or a certified service professional, in accordance with the
National Electrical Code and all applicable local codes and ordinances.
When the pump is not properly installed, it can create an electrical hazard,
which can potentially lead to death or serious injury, due to electric shock
or electrocution.
It is essential to always disconnect power to the pump at the circuit breaker before servicing the pump. Failing to do so can have catastrophic consequences for those involved: Electric shock and property damage are the least of the dangers; Death or serious injury to service people, pool users, or even bystanders can occur.
6 Inches(15.2cm) Minimum
The pump can automatically accept a single phase, 115/208-230V, 50 or 60 Hz input power and No wiring change is required. The power connections (below picture) are capable of handling up to 10 AWG solid or stranded wire.
3 Inches (7.62cm) Minimum
PIPING:
1. The Piping diameter on the intake of the pump should be the same or larger
than the one of the discharge.
2. The shorter of plumbing on the suction side is better. 3. A valve on both
suction and discharge lines is recommended for easy
maintenance and repair. 4. Any valve, elbow or tee installed in the suction
line should be at least five
(5) times of suction line diameter from the discharge port. For example, 2″
pipe requires 10″ straight line before the suction port of the pump, as below
drawing.
5 times of suction line diameter
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-5-
WIRING POSITION
Wiring Position:
For 115V/60HZ input: Terminal L1 (Hot Wire), Terminal L2(N) (Neutral Wire),
Terminal G (Ground wire). This applies to Relaax130-VS & Relaax220-VS.
WARNING
STORED CHARGE – Wait at least 5 minutes before servicing
1. All electrical breakers and switches MUST be turned off before wiring the
motor.
2. Input power MUST match the requirements on the data plate. 3. Regarding
wiring sizes and general requirements, it is important to
follow the specifications as defined by the current National Electric Code and
any local codes. When unsure of what size wire to use, it is always best to
use a heavier gauge (larger diameter) wire for safety and reliability. 4. All
electrical connections MUST be clean and tight. 5. Trim the wiring to correct
size and ensure that the wires do not overlap or touch when they are connected
to the terminals. 6. It is important to reinstall the drive lid after any
electrical installation or whenever leaving the pump unsupervised during
servicing. This is to ensure that rainwater, dust, or other foreign particles
are not able to accumulate in the drive.
Note: Make sure that wires are not pinched between the drive body and lid when installing the drive.
For 208-230V/60HZ input: Terminal L1 (Hot Wire 1), Terminal L2(N) (Hot Wire
2), Terminal G (Ground
wire). This applies to Relaax220-VS & Relaax390-VS.
CAUTION The power wiring cannot be buried in the ground
7. The power wiring cannot be buried in the ground, and the wires must be
positioned to avoid damage from other machines such as lawn movers.
8. To prevent electric shock, damaged power cords should be replaced
immediately.
9. Beware of accidental leakage, do not place the water pump in the open
environment.
10.To prevent electric shock, do not use extension cords to connect to the
power supply.
Grounding:
1. It is important to ensure that the motor is properly grounded using the
Grounding Terminal as shown in below Figure inside the drive wiring
compartment. When installing the ground wire, be sure to follow the
requirements of the National Electrical Code and any local codes for
wire size and type. Additionally, ensure the ground wire is connected to
an electrical service ground for the best results.
WARNING
WARNING electric shock hazard. This pump must be connected to a
power
supply
with leakage protection (GFCI). GFCI systems should be supplied and
inspected by the installer.
For 208-230V/50HZ input Terminal L1 (Hot Wire 1),Terminal L2(N) (Neutral
Wire),Terminal G
(Ground wire). This applies to Relaax220-VS & Relaax390-VS.
Bonding: 1. Using the Bonding Lug located on the side of the motor (Below
Figure ),
bond the motor to all metal parts of the pool structure, electrical equipment,
metal conduit, and metal piping within 5′ (1.5 m) of the inside walls of the
swimming pool, spa, or hot tub. This bonding should be done in accordance with
the current National Electrical Code and any local codes. 2. For American
installations, an 8 AWG or larger solid copper bonding conductor is required.
For Canada installation, 6 AWG or larger solid copper bonding conductor is
required.
Bonding Terminal
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-6-
External Control Via RS485 Signal Cable
RS485 signal cable connection: The pump can be controlled by Pentair control
system via RS485 signal cable (Sold separately).
1. Please strip the cables around 3/4″ (19 mm) and connect green cable to
Terminal 2 and yellow cable to terminal 3 at Pentair Control system.
2. At another end of the signal cable, please connect it to the communica
tion port of the pump and lock up the watertight nut to avoid humidity, Please
look at the below diagram.
3. After successfully connected, the monitor of pump will show ECOM and the
Communication indicator will be lighted up. Then, the pump gives the control
right to Pentair Control System.
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-7-
OPERATION
Setting the Clock:
Hold the Tab button for 3 seconds into time setting,the hour number will
blink, Use / button to set hour, press tab again and move to minute setting.
Use / button to set minute.
Programming an Operation Schedule:
1. Turn on the power, the Power LED light turns on.
Set priming, Quick clean & exhaust time and speed.
For self-priming in ground pool pump (Relaax220-VS & Relaax390-VS), the
factory default setting is running the pump for 10 minutes at maximum speed
3450 RPM. For Non self-priming above ground pool pump (Relaax130-VS), the
factory default setting is running the pump for 1 minute at maximum speed 3450
RPM to exhaust air inside the pipe line. In the Auto Mode, hold button for 3
seconds, speed number(3450) will blink and use / to set priming speed; Then
press button and the priming time will blink, Then use / button to set priming
time.
2. The Default setting is in Auto Mode and those Four speeds are running as below schedule.
Speed
Range of rotation Factory default
450~3450rpm
3000rpm
450~3450rpm
1400rpm
450~3450rpm
2200rpm
450~3450rpm
3450rpm
Run time (factory setting) AM 08:00~AM 10:00 AM 10:00~PM 20:00 PM 20:00~ PM 22:00
Switch from Auto Mode to Manual Mode:
The Factory Default is in Auto Mode. Hold
for three seconds,
the system will be changed from Auto Mode to Manual Mode.
Program Speed and Running time in Auto Mode:
1. Hold one of the speed buttons for 3 seconds, the speed number will
blink. Then, use
/ button to increase or decrease the speed. If
no operation for 6 seconds, the speed number will stop blink and
confirm the settings.
2.Hold one of the speed buttons for 3 seconds, the speed number will
blink. Press the button to switch to running time setting. The running
time at the lower left corner will blink. Use / button to modify Start
time. Press the
button and end time number will blink to be
programmed. Use
/ button to modify End time. The setting
process is the same for Speed 1, 2, & 3.
In the Manual Mode, ONLY speed can be programmed. Hold one of the speed
buttons for 3 seconds, the speed number will blink.
Then, use button to increase or decrease the speed. If no operation for 6
seconds, the speed number will stop blink and confirm the settings.
Note: At any time during the day that is not within the programmed SPEED 1-3, the pump will stay in a stationary state [SPEED 1 + SPEED 2 + SPEED 3 24 Hours ] Note: If you wish for your pump to not run during a certain period of the day, you can easily program the speed to 0 RPM. This will ensure that the pump will not run during the duration of that speed.
The factory default setting for speed under Manual Mode is as
below.
Speed gear Rotating speed
(87%) 3000 r/min
(40%) 1400 r/min
(60%)
2200 r/min
(100%) 3450 r/min
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-8-
OPERATION
Reset factory default setting:
In power off situation, hold
together for three seconds and factory
default setting will be recovered.
Lock / Unlock the keyboard: In the home page, hold
lock/unlock the keyboard.
for 3 seconds at the same time to
Priming:
CAUTION
The pump is preset with priming mode for 10 minutes at 3450RMP when it starts each time.
ALARM: The pump should never run without water. Otherwise, the shaft
seal is damaged and the pump starts to leak, it is essential that the seal is
replaced. To avoid this, it is important to maintain the proper water level in
your pool, filling it to half way up the skimmer opening. If the water falls
below this level, the pump could draw in air, leading to a loss of prime and
the pump running dry and causes a damaged seal, which can cause a loss
of pressure, leading to damage to the pump body, impeller and seal and
result in both property damage and potential personal injury.
Turn off/ turn on button sound:
In the controller displays the home page, press
the button for 3
seconds at the same time, you can turn on/off the button sound.
Button cell replcement: If the power is off unexpectly, when the power is
back, it will run a priming
cycle and, if sucessful, follow preseted operation schedule, the controller
has a backup power by a button cell (CR1220 3V) which has 2~3 year life.
Check before the initial startup – Check that the shaft turns freely. – Check
whether the power supply voltage and frequency are consistent with the
nameplate. – Check for obstructions in the pipe. – A system should be
configured to prevent the pump from starting when there is no minimum water
level. – Check the rotation direction of the motor, it should be consistent
with the indication on the fan cover. If the motor won’t start, try to find
the problem in the table of most common faults and see possible solutions.
Start Open all gates and power on the motor, check the circuit breaker current
of the motor, and adjust the overheat protector appropriately. Apply voltage
to the motor and adjust the nozzle properly to obtain the desired flow.
Turn on the power, the POWER indicator light is on, and the inverter is in the
stop state. The system time and icon are displayed on the LCD screen. Press
the key, the water pump starts or stands by, and runs at a speed of 3450r/min
for 10 minutes each time it starts (Note 1). At this time, the LCD screen
displays the system time, icon, running icon, SPEED 4, 3450RPM and countdown
of primg time; after 10 minutes of running , work according to the preset
automatic mode (the system time,
icon, running icon, rotating speed, start and stop running time, multi-stage
speed number are displayed on the screen), and the multi-stage speed is
executed sequentially in chronological order (there are multiple-stage speed
settings in the same time period) , the running priority is: > > ), if there
is no need for a multiple-stage speed, it is necessary to set the start and
end time of the multiple-stage speed to be the same.
Priorities Note: In the case of a pump that is installed below the water line
of a pool, ensure that the return and suction lines are closed before opening
the
strainer pot on the pump. Before operating, reopen valves.
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-9-
MAINTENANCE
ALARM: It is important to be aware that if the pump fails to prime or has been
operating without water in the strainer pot, it should not be opened. This is
because the pump may contain a build up of vapor pressure and scalding hot
water, which could result in serious personal injury if opened. To ensure
safety and avoid potential personal injury, all suction and discharge valves
must be opened carefully. Additionally, you should verify that the strainer
pot temperature is cool to the touch before proceeding to open the valves with
extreme caution.
ATTENTION: To ensure that the pump and system remain in optimal working
condition, it is important to clean the pump strainer and skimmer baskets
regularly.
ALARM: Before servicing the pump, turn off the circuit breaker. Electric shock
could kill or seriously injure service workers, users, or others if this is
not done. Before servicing the pump, read all servicing instructions.
Cleaning the pump strainer & skimmer basket:
It is highly recommended to check the Strainer Basket as frequently as
possible to clean up the trash. The safety instruction is as follows: 1. Press
Stop/ Start to stop the pump. 2. Turn off power to the pump at the circuit
breaker. 3. In order to relieve all pressure from the filtration system, the
filter air
relief valve must be activated. 4. To remove the strainer pot lid, twist it in
a counterclockwise direction. 5. Take the strainer basket out from the
strainer pot. 6. Clean up the trash from Basket. Note: If there is any cracks
or damage on the basket, replace it with a new one. 7. Carefully lower the
basket into the strainer pot, making sure that the notch in the bottom of the
basket is aligned with the rib on the bottom of the pot. 8. The strainer pot
should be filled with water up to the inlet port. 9. The lid, O-ring and
sealing surface should be Cleaned carefully. Note: Keeping the lid O-ring
clean and well lubricated is essential to maintain the life and performance of
the pump. 10. Install the lid onto the strainer pot and turn the lid clockwise
in order to
lock it securely into place. Note: In order to properly lock the lid, the
handles need to be nearly perpendicular to the pump body. 11. Turn on power to
the pump at the circuit breaker. 12. Open the filter air relief valve 13. Keep
away from the filter and turn on the pump. 14. To bleed air from the filter
air relief valve, open the valve and let the air
escape until a steady stream of water appears.
DANGER
All parts of circulation system (Lock Ring, Pump, Filter, Valves, and so on) are running under high
pressure. Pressurized air can be a potential hazard because it can cause
the lid to be exploded off, potentially resulting in serious injury, death, or
property damage. In order to avoid this potential hazard, please follow
above safety instructions.
Winterizing:
It is important to note that freeze damage is not covered under warranty. If
freezing temperatures are predicted, there are steps you can take to reduce
the risk of freeze damage. 1. Press Stop/ Start to stop the pump. 2. Turn off
power to the pump at the circuit breaker. 3. In order to relieve all pressure
from the filtration system, the filter air
relief valve must be activated. 4. Carefully unscrew two drain plugs from the
bottom of the strainer pot,
and allow the water to drain completely. Place the drain plugs in the strainer
basket for storage. 5. It is important to cover your motor when exposed to
extreme weather conditions, such as heavy rain, snow and ice. Note: Wrapping
the motor with plastic or any other airtight material is prohibited. When the
motor is in use, or when it is expected to be in use, MUST NOT cover the
motor. Note: In mild climate areas, it is recommended to run the equipment all
night when freezing temperatures are forecast or have already occurred.
Pump care:
Avoid Over-heating 1. Shield from sun & heat 2. Well ventilated environment to
avoid over-heating
Avoid messy working conditions 1. Keep working conditions as clean as
possible. 2. Keep chemicals away from motor. 3. Dust should not be stirred up
or swept near the motor during operation. 4. Dirt damage to the motor may void
the warranty. 5. It is important to clean the lid, the O-ring, and the sealing
surface of the
strainer pot.
Keep away from moisture 1. Splashing or sprayed water should be avoided. 2.
Flood protection from extreme weather. 3. Ensure that the pump is protected
from extreme weather conditions
such as flooding. 4. Let the motor internals dry before operating if they have
become wet. 5. Flooded pumps should not be operated. 6. Water damage to a
motor may void the warranty.
Lid
O-Ring Basket Strainer pot
Restart the Pump Priming the pump 1. Turn off power to the pump at the circuit
breaker. 2. In order to relieve all pressure from the filtration system, the
filter air
relief valve must be activated. 3. To remove the strainer pot lid, twist it in
a counter-clockwise direction. 4. The strainer pot should be filled with water
up to the inlet port. 5. Install the lid onto the strainer pot and turn the
lid clockwise in order to
lock it securely into place. Note: In order to properly lock the lid, the
handles need to be nearly perpendicular to the pump body. 6. Turn on power to
the pump at the circuit breaker. 7. Open the filter air relief valve. 8. Keep
away from the filter and turn on the pump. 9. To bleed air from the filter air
relief valve, open the valve and let the air
escape until a steady stream of water appears. When the priming cycle is
complete, the pump will begin normal operation.
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-10-
TROUBLE SHOOTING
Faults and codes
No. Codes Fault description Possible failure cause
Countermeasures
1
E001
IPM module failure
1. Rising speed is too fast; 2. Power electronic
components are damaged; 3. Interference causes Mis-
operation; 4. Poor ground connection
Extended acceleration time Check whether there is strong interference around Check the ground wire Contact the supplier
1. Accelerating too fast;
2
E002
Output current 2. decelerating too fast; exceeds the limit 3.Sudden change or
abnormality of load;
Extended acceleration time Extend the deceleration time Check the load or reduce the load sudden change
3
E006
Input voltage is too high
1. Abnormal input voltage; 2. Slowing down too fast; 3. Load disconnection.
Check the input power Increase deceleration time Check if the load is disconnected
4
E009
Input voltage is too low
1. Input voltage is low
Check input power
5
E010
Inverter overload
1. Accelerating too fast. 2. The motor restarts without
stopping. 3. The voltage is too low. 4. Too much load.
Increase acceleration time. Avoid shutting down and restarting. Check the network voltage. Choose an inverter with higher power.
1. The voltage of the power
6
E011 Motor overload
grid is too low.
Check the voltage.
2. The motor stalls or the load Check the load.
changes suddenly.
1. U, V, W phase loss.
7 E013 Output phase loss 2. The three-phase load is
seriously unbalanced.
Check output wiring. Check the motor and cables.
1. The air duct is blocked.
Drainage channel.
2. The ambient temperature Reduce the ambient
8 E014 Inverter overheating is too high.
temperature.
3. The control panel is
Contact suppliers and seek
abnormal.
services.
9
E018
Faulty current sampling circuit
1. The current detection element is abnormal.
2. Abnormal amplifier circuit.
Contact suppliers and seek services. Contact suppliers and seek services.
10 E021
Display board EEPROM failure
1. Bad connection between the display board and the main drive board.
2. EEPROM damage.
Replace the connecting cable between the display board and the main drive board. Contact suppliers and seek services
11 E048
PFC over current
1.The grid voltage is too low; 2. PFC circuit failure
Check the network voltage Contact suppliers and seek services
E002 will automatically recover, and other fault codes will appear, the inverter will stop, and it needs to be powered off and on again to restart the inverter.
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-11-
INSTALLATION DIAGRAM AND TECHNICAL DATA
Installation diagram
Water pump
Stand filter
Vacuum hose Vacuum head
Technical Data
Model
Voltage (V)
Frequency Power (Hz) (THP)
Current (A)
WEF
Relaax130-VS 115
Relaax220-VS 115/208-230
Relaax390-VS
230
50/60 50/60 50/60
1.3
12
11.3
2.2 13.8/8.5-7.4 8.8
3.9
13
7.3
Hmax (m)
17 23 27
Qmax (L/min)
Speed (r/min)
G.W (Kg)
330 450~3450 13.8 510 450~3450 20 650 450~3450 25.8
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-12-
PERFORMANCE CURVE AND INSTALLATION SIZE
Relaax130-VS
0
H H0 (psi) ( m)
18 24 16
14 18 12
10 12 8
6 6 4
2
0 0 0
0
15
30
45
60
75
15
30
45
60
90 U. S.GPM 75IMP.GPM
H ( ft)
50 40
30
20
10
50 100 150 200 250 300 350 l/min
3
6
9 12 15 18 21 m3/h
Flow
Relaax220-VS
0 H H0 (psi) (m) 35 25
30 20
25 20 15
20 40 60 80 100 120
20
40
60
80 100
U. S.GPM
IMP.GPM H (ft)
75
60
45
15 10
30
10
55
15
00 0 0
0
100
200
300
400
500 l/min
6
12
18
24
30 m3/h
Flow
Relaax390-VS
235 E
76
E
11/2-
11.5NPT or
G 11/2
344 518
237
133
226
572
17×11.5 133
253 G2
260 257 60
122
264 257
220
276
11
200
142
605
240
261
LINGXIAO Technical Support Center: Please visit www.lingxiaopumps.com or
contact us by phone/whatsApp: +1 647 800 0468
-13-
WARRANTY & CONTACT US
Warranty period
The warranty period is one year since the date of purchase. The warranty
period can be extended by one more year if you fill in the “Customer
Information Registration Form” on our After Sales Website:
www.lingxiaopumps.com.
Warranty scope: natural damage occurred during normal use within the warranty
period; If one of the following situations occurs, it is not covered by the
warranty:
Damage caused by abnormal working environment or storage conditions;
Damage caused by incorrect operation or use; Damage caused by repairing the
product without our permission; Adding, modifying, and replacing parts of the
product unauthorizedly; Man-made vandalism; Irreparable damage caused by force
majeure and natural disasters;
Scope of maintenance
If the product cannot work normally under the specified conditions due to
defects or errors in components, materials and manufacturing technology during
the warranty period, the company will repair or replace it free of charge;
Remarks: The logistics cost of sending back to the company’s repair center
needs to be paid by the customer, and the company only pays the maintenance
cost and the logistics cost of sending back to the customer.
Service Commitment
Within 30 days from the date of sale (according to the sales invoice or the
date of order issuance), if the user is not satisfied with the quality of the
product, and the product is not damaged by man-made or improper use, When the
company confirms that the product cannot be repaired, the company will replace
it for free;
During the warranty period, if the product are naturally damaged under normal
use, the company will provide free warranty. PLEASE USE THE ORIGINAL BOX AND
PROTECTION FOAM TO SEND THE PUMP BACK TO THE DESIGNATED ADDRESS IN ORDER TO
AVOID DAMAGE DURING TRANSPORTATION.
Customer Service/ WhatsApp: +1 647 800 0468 Email: Sales@lxpumps.cn Website:
www.lingxiaopumps.com
All indicated LINGXIAO trademarks and logos are our property. Third parties
own their registered and unregistered trademarks and logos. Since our products
and services are continuously being improved, all rights are reserved to
change specifications without prior notice.
LINGXIAO All rights reserved. This document is subject to change without
notice.
-14-