LG RESU6.5 Compatible Inverters

Specifications

  • Compatible Batteries: RESU6.5, RESU10, RESU12, RESU13
  • Output Power: Varies based on battery model
  • Compatible Inverters: List provided below
  • Operating Mode: On-Grid only (Backup mode under specific conditions)

Product Usage Instructions

  1. Compatibility: Ensure to use a compatible inverter listed below with the respective RESU model.
  2. Operating Mode: Use the battery inverters in On-Grid mode only, except in specific Off-Grid conditions as mentioned.
  3. Back-up Mode: If utilizing Back-up mode, ensure that backed-up circuits and inverter’s AC draw do not exceed battery current limit specifications.

List of Compatible Inverters

Brand Inverter Model Software Version*

FAQ

  1. Can I use a non-approved inverter with LG Energy Solution Home Battery?
    No, using a non-approved inverter will void the warranty provided  by LG Energy Solution.

  2. Can I use the battery inverters in Off-Grid mode?
    Only under specific conditions mentioned in the manual.

List of Compatible Inverters with LG Energy Solution Home Battery

RESU6.5 RESU10 RESU12 RESU13

Compatible storage Inverters with RESU LV

All RESU installations require a compatible inverter. Using a non-approved inverter will void the warranty provided by LG Energy Solution. See below important instructions when installing and using RESU LV.

  1. Battery inverters should operate in On-Grid only. (Not in Off-Grid, except as noted below)
  2. For On-Grid applications where Back-up mode may be sometimes utilized the backed up circuits and inverters AC draw must not exceed the battery current limit specifications.

The following list of Inverters are currently compatible with LG Energy Solution home battery, RESU LV Series.

INVERTER| BATTERY|

REMARK

---|---|---
Brand| Model| **Software Version*| RESU6.5 (4.2kW)| RESU10 (5kW)| RESU12 (5kW)| RESU13 (5kW)*
| LGES-5048| All software version| ○| ○| ○| ○|
Can use in Back-up Mode under the condition 2) above

| ES-G2 6.0-1LU-20| DSP : 04 or above ARM : 05 or above| ○| ○| ○|  |

*Can use in Back-up Mode under the condition 2) above

GW5048D-ES| FW : 15158| ○| ○| ○| ○
GW3048-EM GW5048-EM| FW : 06068| ○| ○| ○| ○
GW3600S-BP GW5000S-BP| FW : 05058| ○| ○| ○| ○

| SH5K SH5K+| SH5K_V11_V1_A SH5K-V13_FW_V13| ○| ○| ○|  |

*Can use in Back-up Mode under the condition 2) above

SH3K6 SH4K6 SH5K-20

SH5K-30

| SH3K6-V11_FW_V28 SH4K6-V11_FW_V28 SH5K-20_FW_V57 SH5K-30_V01_V006|

|

|

|

| Sunny Island 3.0| 3.110| ○| ○| |  | *Can be used in Back-up Mode under the condition 2) above, exclusively for C10, C12, and C13.

C6.5 cannot be used in back-up mode.

Sunny Island 4.4M| 3.00.03.R| ○| ○| ○| ○
Sunny Island 6.0H| 3.00.03.R| ○| ○| ○| ○
| SPMC480-AU SPMC481-AU SPMC482-AU| SP Link : 11.15.7006

/ 15.0.8139.29909

| ○| ○| ○| ○| *Exclusively, can use in Off-Grid

*For all enblock C models, adding in parallel increases capacity, but does not increase available current

beyond 5kW continuous.

| S5-EH1P3K-L S5-EH1P3.6K-L S5-EH1P4.6K-L S5-EH1P5K-L S5-EH1P6K-L| 320020| ○| ○| ○| ○| Can use in Back-up Mode under the condition 2) above
RHI-3K-48ES-5G RHI-3.6K-48ES-5G RHI-4.6K-48ES-5G RHI-5K-48ES-5G RHI-6K-48ES- 5G| 320020| ○| ○| ○| ○|
Can use in Back-up Mode under the condition 2) above

  • Only compatible with the software versions which are mentioned above.
  • All inverters matched with RESU LV are compatible with parallel box.