Product Information

Specifications

  • Frequency: 433.92MHz / 447.7MHz
  • Battery: 3V (CR2430)
  • Emitter Specification: DC305(A/G), DC307(A/G), DC306(A/G/E), DC313(A/G/E)
  • Matchable Tubular Motor Set up: DC227/DC228, DC136

Product Usage Instructions

Emitter Setup

  • The product is compatible with emitters DC305(A/G), DC307(A/G), DC306(A/G/E), and DC313(A/G/E).

Tubular Motor Set up

  • The product can be set up with matchable tubular motors such as DC227/DC228 and DC136.

Button Functionality

  • Although models DC305G, DC306G, DC306E, DC307G, DC313G, and DC313E have different button marks, their functions are the same.

FAQ

Q: Do all models have the same functions?

A: Yes, models DC305(A) DC306(A) DC307(A) DC313(A) have different button marks but the same functions.

Q: What batteries does the product use?

A: The product uses a 3V CR2430 battery.

Technical Support

  • Input voltage: 3V(CR2430)
  • Transmitting frequency: 433.92MHz
  • Transmitting power: 10 milliwatt
  • Operating temperature: – 20°C ~ + 55°C
  • Transmssion distance: 200 meters open office 35 meters on two walls

Transmitter: You can choose the single channel (DC305(A/G) ), or five channels(DC306(A/G/E) ). Each indicator light means one control channel. Press the “channel choose” button Pi-(indicator move left side) or P1 +(indicator move right side) to change the channel. On the analogy of this, lose your finger when the indicator light moves to a suitable channel that you select the effective channel. All indicator lights flash which means all channels are effective(group control state).
Transmitter: You can choose nine channels (DC307(A/G) ), and fifteen channels(OC313(A/G/E)). One number of LCD screens means one control channel. Press the” channel choose”button Pi-(number descending) or P1 +(number increasing) to change the channel.
On the analogy of this, lose your finger when the indicator light moves to a suitable channel that you select effective channel.
If the LCD screen number shows o that means all channels if effective(group control state).

Notice: The transmitter Is not exposed to moisture and strike, so as not to affect life.
When you use a transmitter, if found emission distance is short or less sensitive, please change the same new battery. Please have batteries for recycling.

  • All controls support 433MHz & 868MHz& 447.7 MHz
  • All controls support 3V(CR2430)
  • Specific parameters to the nameplate shall prevail

USING INSTRUCTIONS

Matchable R Tubular Motor Set up

  • Delete all the data of the motor and the new emitter has been programmed.
  • Each time, the interval of pressing different buttons must be within 4 seconds when you re-setting all instructions, otherwise, the system will restore the original state.

LAWSON-DC305A-Remote-Control-for-Tubular-Motors-FIG-2

Matchable DC227/DC228 Tubular Motor Set up

  • The interval of the different buttons must within 10 seconds for all setting, otherwise the system will restore the original state
  • One receiver stores 20 emitter channels at most, and one channel of emitter can control 20 receivers at most.

LAWSON-DC305A-Remote-Control-for-Tubular-Motors-FIG-3

Matchable DC136 Tubular Motor Set up

  • The interval of different buttons must be within 10 seconds for all settings, otherwise, the system will restore the original state.
  • One receiver stores 20 emitter channels at most, and one channel of emitter can control 20 receivers at most.

LAWSON-DC305A-Remote-Control-for-Tubular-Motors-FIG-4

Type Specification

LAWSON-DC305A-Remote-Control-for-Tubular-Motors-FIG-5

  • DC305G DC306G DC306E DC307G DC313G DC313E and DC305(A) DC306(A) DC307(A) DC313(A) have different button marks, but the function is the same.

FCC STATEMENT

Caution
This device complies with Part 15 of the FCC. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference,
  2. this device must accept any interference received, including interference that may cause undesired operation. responsible to complicate could the users aulriy the operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.