Safety Information

Warning!

  • ONLY use this pump in accordance with these instructions, all applicable local and national laws, and for its intended purpose, transferring fuel and other liquids.
  • DO NOT allow use by children or those unfamiliar with this product or the safe handling of the fluids being transferred. Do not use while under the influence of alcohol, drugs, or any medication that negatively affects your judgment or reflexes. Keep children and bystanders away during use.
  • Keep your work site clean and well lit. Cluttered and dark work areas invite accidents.
  • For best results, keep the kit clean and dry. Remove any fluid, oil, or grease before and after work, particularly from the handle and fittings.
  • ALWAYS use personal protective equipment (PPE) suitable to your task. Always wear ANSI- approved eye and hand protection while using this product. Nonslip footwear is also highly recommended. Other equipment such as breathing, ear, head, and body protection may also be necessary depending on your work and other equipment.
  • Exercise EXTREME caution when using this pump for flammable liquids. Avoid all other flammable materials and any sources of heat, flames, or sparks.
  • NEVER use this pump for any liquid intended for human consumption. Clean and sanitize it completely before any use with liquids for animal consumption.
  • Maintain this product. Check for misalignment, binding, wear, or other damage before use.
    If any damage is detected, repair or replace the problematic components before further use.
    In a large shop, mark such tools DO NOT USE until they have been repaired. Only replace components with identical parts.

Specifications

Material AISI 1045 Steel, Zinc Alloy
Pumping Capacity / Stroke 10 fl. oz.

Product
Dimensions| Main Body| 18.1×1.2×1.2  in.| 46×3×3 cm
Suction Tube| 35.8×1.5×1.5 in.| 91×3.7×3.7 cm
Handle| 12.6×0.9×1.8 in.| 31.9×2.2×4.6 cm
Spout| 4.8×1.3×4.1 in.| 12.3×3.4×10.4 cm
Net Weight| 4.1  l b.| 1.9 kg

Parts List

Ejoyous V20230615 Lever Action Barrel Pump - Parts
List

No. Name Qty.
A ¾″ Spout 1
B Lever Handle 1
C Telescoping Suction Tube 1
D Pump Body 1
E M5 Nut 1
F M5 Bolt 1
G Wrenches 2
H Thread Seal Tape 1
G Gloves 2

Not Included but Necessary
Adjustable Wrench, Pliers

Product Diagram

Ejoyous V20230615 Lever Action Barrel Pump - Product
Diagram

Assembly

  1. Apply some thread seal tape (H) around the angled outlet located on top of the main body (D). Take the spout (A) and check that its rubber gasket is well positioned. Screw the spout directly onto the taped outlet. Tighten the spout’s nut securely with your adjustable wrench (not included).
  2. Pull the plunger rod up from the top of the main body using your pliers (not included). Remove the upper bolt and pin from the lever (B), align the upper bolt hole in the lever with the hole on the plunger rod, and replace the bolt. Insert the pin through the bolt and pull its legs apart to secure it.
  3. Use the provided M5 bolt (E) and nut (F) to attach the lever’s lower bolt hole to the bracket on the main body. Securely fasten them with the provided wrenches (G).
  4. Apply thread seal tape to the threading on the telescoping suction tube (C). Screw the tube into the bung nut at the bottom of the main body. Use moderate torque and do not force or overtighten the parts.

Operation

  1. Open the bung on any standard 55-gallon drum. Adjust the telescoping suction tube by loosening the drum adapter, extending the tube as needed, and retightening the adapter.
  2. Insert the tube into the drum, fully immersing its lower end, and create a secure seal between the adapter and the edge of the bung, twisting the main body as needed. Do not disturb the lever during this process.
  3. Position your receiving container directly under the spout or connect the spout to the container using any suitable ¾ inch tube.
  4. Use the pump lever in steady controlled motions to begin transferring your fluid. To minimize waste, continue pumping until the pump goes dry. Alternatively, raise the pump and tube from the liquid and use the pump lever to empty the last bit of fluid still within the pump itself.
  5. After use, clean any fluid from the pump’s surfaces before putting it away.

Maintenance

  • Clean the surfaces of this tool with a dry brush or cloth after use. Do not rinse it and do not use abrasive cleaners or caustic chemicals.
  • For best results, lubricate this tool with high-quality anticorrosive oil between uses.
  • Check the parts of this tools periodically for any wear or damage. Repair or replace any problematic parts before further use.
  • If this tools will not be used for an extended period of time, lubricate it and store it in a cool dry place inaccessible to children.

Contact Us

Thank you for choosing our products! If you have any questions or comments, contact us at [email protected] and we’ll resolve your issue ASAP!
For a .pdf copy of the latest version of these instructions, use the appropriate app on your smartphone to scan the QR code to the right.

https://sp9c.com/yp9QH